• 제목/요약/키워드: Partial denture

검색결과 422건 처리시간 0.02초

편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구 (STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH)

  • 안광호;정영완;진태호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교 (Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application)

  • 전인식;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

한국인의 부분 치아 결손 증례와 국소의치 설계에 관한 연구 (A SURVEY OF PARTIAL EDENTULISM AND REMOVABLE PARTIAL DENTURE DESIGNS FOR PATIENTS IN KOREA)

  • 이시혁;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.235-248
    • /
    • 1994
  • There were many studies that distribute the partial edentulous states and examine the removable partial denture designs in the planning of removable partial denture treatment. This study was performed in the point of removable partial denture prescription to evaluate partial edentulism and its removable partial denture designs. The data was collected from the dental laboratory of each three dental colleges in Seoul and from two dental laboratories only for removable partial dentures as a prescription form. A total of 1411 cases with prescription form collected from dental laboratories were distributed for this study, then 788 cases were selected for this study. The case selection was done according to the contents of prescription form. The selected cases were divided into maxillary arch and mandibular and classified in terms of types of major connector and direct retainer, unbroken anterior teeth, Kennedy classification, the number of remaining teeth, and distribution of age and sex. The analyzed results were as follows : 1. The Kennedy classification I showed highest frequency both in maxilla and mandible. 2. The arch distribution of removable partial denture was 50.08% for maxilla and 49.92% for mandible. 3. The highest frequency in the distribution of direct retainer was the RPA clasp design. 4. The frequency of unbroken anterior 6 was 73.36% for maxilla and 82.30% for mandible. 5. The design of broad palatal strap and lingual bar revealed the highest prevalence in the major connector construction. 6. The mean number of remaining teeth per arch was 8.25 for maxilla and 8.37 for mandible. 7. The mean age of the patients supplied with removable partial denture was 52.25 years for men, 51.68 years for women, 52.11 years for maxilla, and 51.76 years for mandible and women showed more prevalence.

  • PDF

Immediate fixed partial denture after tooth extraction in patients with systemic diseases: A clinical report

  • Kang, Hyun Sun;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.511-514
    • /
    • 2016
  • For patients with systemic diseases who face difficulties visiting dental clinics, wearing fixed partial denture in the anterior region on the same day of tooth extraction can reduce the total period of treatment and the number of visits, as well as post-treatment psychological effect on the patient.

발플라스트 레진 주입 시 발생되는 의치상의 두께변화에 관한 연구 (Research for Thickness Change of Denture Base in Flask when Injecting Valplast Flexible Partial Denture Resin)

  • 장완영;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.47-56
    • /
    • 2008
  • This is a research for thickness change of denture base according to the shape of sprue & investment position of denture base in flask when injecting polyamid base resin for flexible partial denture as a part of study for Valplast among the flexible partial denture with a nylon base. It has been introduced several kinds of flexible partial denture product with a nylon base, but Valplast is the most widely used product among them. Valplast has been the most generally used material today since developed in 1950s in the United States as a material for flexible partial denture. Valplast is much more aesthetic than general metal-acrylic partial denture due to its translucent pink color and biocompatibility in terms of material characteristic. It keeps its flexibility for a long time after production, imposes a less burden on the teeth used as abutment, and it can be easily insert and remove due to its particular suppleness. Moreover, it is felt like real teeth more than metal-acrylic partial denture when being put in and takes alveolar bone under good protection since it receives occlusal force equally under the denture base. The most outstanding feature of Valplast is flexibility. The extent of its flexibility is determined by width & thickness of denture base. Considering general working procedure of Valplast, it can be seen that the thickness of denture base formed out of wax is increasing by the pressure while injecting resin. This research is to decide and test on the thickness increasing of Valplast by injecting pressure and the hypothesis upon that and is to prepare the basis estimating the increasing extent of thickness of denture base on the basis of the test result. In this test, it is expected occlusal malposition & thickness increasing of denture base by injecting pressure according to 4 kinds of test data which are to select 3 types of sprue method settling the forefront position at which the test material of fixed standard can be invested and to position the test material at the rearmost part keeping the minimum distance to set sprue. For 4 kinds of injecting test by investment position & sprue type, 20 test materials, 5 for each test were produced and a pressure of 1,180Kg was given with automatic injector of air cylinder type. The results are as follows: 1. For the amount of thickness increasing of denture base by investment position, the thickness of front investment is less increasing than the one of rear investment. 2. For the amount of thickness increasing of denture base by sprue type, the thickness of straight decompression sprue type which can absorb the injecting pressure after injecting polyamide base resin is less increasing than the other sprue types.

  • PDF

국부의치 설계에 관한 임상적 연구 (A CLINICAL EVALUATION ON THE DESIGN OF REMOVABLE PARTIAL DENTURE)

  • 장익태
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.66-71
    • /
    • 1976
  • The purpose of this investigation was to evaluate the mouth preparation and design of removable partial dentures. A total of 187cases for the prefabricated partial denture frameworks in both maxillary and mandibular semi-dentulous situations (66 cases and 203 cases) was selected from this study. The evaluations of mouth preparation and design observed here involved the classification of edentulous spaces, status of abutment splinting with location, design of direct retainer and structure of maxillary major connector according to the incidence of both dental arches, ages, sexes and segment of semidentulousness. The analyzed results were as follows: 1) The order of frequency rate in removable partial denture construction was Class II (50.27%), Class I (36. 90%), Class III (10.69%), and Class IV (2.14 %). 2) The distribution on design of maxillary removable partial denture prosthesis was 33.22% and 64.11% in mandibular removable partial denture prosthesis. 3) The age distribution of removable partial denture prosthesis was prominent after40 years (41.71%). 4) The design pattern of maxillary major connectors was in order of anteroposterior bar, single palatal bar, palatal strap, U-shape connector. 5) The design pattern of direct retainer was in order of Aker's clasp, I-bar clasp, backaction clasp, cuspid universal clasp. 6) The abutment for partial denture clasp splinted between premolar and premolar and its frequency rate revealed 53.44%. 7) It seemed that the location and design of the indirect retainer showed accepatble limit.

  • PDF

상악 소수치 잔존 환자에서 임플란트를 이용한 가철성 부분틀니 수복 증례 (Rehabilitation of maxillary partial edentulous patients using implant assisted removable partial denture)

  • 이보라;김지환
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.128-135
    • /
    • 2014
  • 부분 무치악 환자는 고정성 보철, 가철성 국소의치, 임플란트 지지 고정성 보철로 수복될 수 있다. 그러나 소수 잔존치아만 남은 경우, 고정성 보철로는 수복이 어려우며, 국소의치 혹은 임플란트 지지 고정성 보철을 고려하게 된다. 이 경우 임플란트 지지 고정성 보철은 고정성 수복이라는 장점이 있으나, 충분한 개수의 임플란트가 식립되어야 하며, 환자의 전신적, 국소적 여건이 합당해야 하고, 경제적 부담도 크다. 가철성 국소의치는 지대치에 의한 대칭적인 지지가 중요하며, 특히 중심선에 대해 편측으로 소수 치아만 남은 경우에는 지점선에 대해 지대치에 유해한 스트레스를 가하면서 지대치의 예후가 불량해진다. 이 경우, 전략적 위치에 임플란트를 식립함으로써 임플란트를 의치의 유지 및 지지 요소로 활용하는 가철성보철물을 설계한다면 비용 대비 기능적이며 심미적인 보철 수복이 가능해진다. 본 두 증례는 상악 Kennedy Class I 부분 무치악 환자 중 편측으로 소수 잔존치가 전치에 국한하여 존재하는 경우로, 잔존치를 지대치로 사용하면서, 전략적 위치에 임플란트를 식립함으로써 의치의 지지가 향상된 국소의치를 제작한 증례이다.

임플란트를 이용한 국소의치 수복 (Implants in conjunction with removable partial denture)

  • 김성균;유수연;박인필;이주희
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

치아지지및 유리단 국소의치의 설계원칙 (THE PRINCIPLE OF THE TOOTH-BORNE AND FREE-END REMOVABLE PARTIAL DENTURE DESIGN)

  • 계기성
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.217-229
    • /
    • 1990
  • The Applegate-Kennedy classification, the drawing of removable partial denture design using color coding, the selective tissue placement impression method in case of Class I and Class II removable partial dentures, the design of the swing lock attachment of an alternative approach to conventional removable partial denture, the design of the intracoronal or extracoronal attachment, and the removable partial denture design using a rotational path were presented. The following conclusions from the above things were presented : 1. The swing lock attachment removable partial denture can be effective to an alternative approach when the design of conventional removable partial denture is improper with markedly mobile remaining teeth or missing key abutments. 2. Intracoronal or extracoronal attachments must be selected care-fully considering the conditions of the abutment teeth and alveolar ridge whether more occlusal loads to the abutment teeth or to the alveolar ridge are distributed. 3. It must be almost prerequisite that a functional impression is taken in case of Class I and class II removable partial dentures and in case of tooth-borne removable partial dentures, a removable partial denture using rotational path is strong, hygienic, esthetic, and can be accomplished successfully in the clinical aspect when it is properly designed and fabricated through the complete understanding of an indication and a principle. 4. All necessary informations must be achieved with carefully investigated surveying procedure according to each clinical case by Applegate-Kennedy classification which can be helpful and useful in the clinical application and it is important that dentists themselves must be in the habit of drawing a reasonable partial denture design using a color coding in the paper sheet.

  • PDF

하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고 (Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report)

  • 기원진;박재호;임현필;윤귀덕;박상원
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.176-181
    • /
    • 2019
  • 편측 부분 무치악에서 소수의 치아로 지대치를 형성하여 가철성 국소의치 제작 시 환자의 불편함 및 지대치 손상 등으로 인해 만족도가 낮아질 수 있다. 최근 편측 부분 무치악에서 임플란트 고정성 보철물을 지대치로 사용하여 양측성 후방 연장 국소의치로 제작하는 방법이 보고되고 있다. 본 증례에서 임플란트 고정성 보철물을 사용하여 환자의 수직 악간관계를 보존하고 본인의 치아와 같은 형태를 부여하여 환자에게 심리적 안정감을 주며 향상된 저작 기능의 결과를 제공하였다. 또한 임플란트 고정성 보철물을 통하여 예후가 불량할 것으로 예상되는 편측성 후방 연장 국소의치를 역학적, 기능적으로 유리한 양측성 후방 연장 국소의치를 제작하였다. 국소의치의 지지, 유지, 안정 요소의 향상을 가져왔으며 환자에게 경제적 및 사용 시 만족감을 가져왔다.