• Title/Summary/Keyword: Partial attenuation filter

Search Result 9, Processing Time 0.021 seconds

Half Wavelength Partial H-Plane Filter with Inverters having Attenuation Poles (감쇄극 인버터를 이용한 반파장 Partial H-Plane 여파기)

  • Kim, Dong-Jin;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • This paper presents half wavelength partial H-plane filters with multiple attenuation poles using narrow H-plane slot of evanescent waveguide. The narrow H-plane slot operates as an admittance inverter o( the bandpass filter and, simultaneously, generates an attenuation pole at particular frequency. Therefore, proposed filters with attenuation poles are simply implemented without any additional coupling and extra modification of the structure. The number of attenuation poles of the filters equals to that of the H-plane slots. Moreover, proposed filters are compact waveguide filter since ones are embodied by partial H-plane waveguide which has 1/4 cross section of conventional waveguide. The third and fourth-order half wavelength filters having 4 and 5 attenuation poles, respectively, are designed in H-band and their frequency responses are confirmed by simulation and measurement.

Scatter Dose in soft tissue using the partial attenuation filter for 6 MV X-ray of linear accelerator (6 MV 광자선조사면내 투과성필터에 의한 조직선량)

  • 최태진;김옥배
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.55-71
    • /
    • 1993
  • Measured and calculated the TMR and SMR factors from percent depth dose underpartial attenuators which cover the whole part of the radiation beam with variousfilter thickness from 0 to 50 mm. This study was performed for x-ray beams generated with a 6 MV linear acceleratorat source to surface distance of 100cm in a water phantom for Lipowitz metal. TMR(0,d,t) was derived from non-linear polynomial regression with field sizedifferencies and a given filter thickness. In this experiments, the TMR(0,10,50) of 50mm of filter thickness was showed13.6 % higher than that of open field and SMR(5,10,50) was 38.5% smaller than thatof open field in same depth.

  • PDF

Performance Improvement of the Active Noise Control System Using RCMAC and PSO Method (RCMAC 및 PSO 기법을 이용한 능동 소음제어 시스템 성능 개선)

  • Han, Seong-Ik;Shin, Jong-Min;Kim, Sae-Han;Lee, Kwon-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1900-1907
    • /
    • 2010
  • In this paper, a recurrent cerebellar modulation articulation control with praticle swarm optimization (PSO) method has been investigated for improvement of noise attenuation performance in active noise control system. For narrow band noise, FXLMS and RCMAC has a partial satisfactory noise attenuation. However, noise attenuation performance is poor for broad band noise and nonlinear path since it has linear filter structure. To improve this problem, a RCMAC with PSO is proposed and it is shown that satisfactory noise attenuation performance is obtained by some simulations in duct system using harmonic motor noise and KTX cabin noise as a noise source.

Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings (고압전동기 고정자 권선에서 부분방전 펄스의 전송)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.

Improvement Noise Attenuation Performance of the Active Noise Control System Using RCMAC (RCMAC를 이용한 능동소음 제어시스템의 소음저감 성능개선)

  • Han, S.I.;Yeo, D.Y.;Kim, S.H.;Lee, K.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.56-62
    • /
    • 2010
  • In this paper, a recurrent cerebellar modulation articulation control (RCMAC) has been developed for improvement of noise attenuation performance in active noise control system. For the narrow band noise, a filter-x least mean square (FXLMS) method has bee frequently employed as an algorithm for active noise control (ANC) and has a partial satisfactory noise attenuation performance. However, noise attenuation performance of an ANC system with FXLMS method is poor for broad band noise and nonlinear path since it has linear filtering structure. Thus, an ANC system using RCMAC is proposed to improve this problem. Some simulations in duct system using harmonic motor noise and KTX cabin noise as a noise source were executed. It is shown that satisfactory noise attenuation performance can be obtained.

Result of Radiation Therapy of Sino-nasal Cancers Using Partial Attenuation Filter (투과성 필터를 이용하여 방사선 치료를 받은 부비동 및 비암의 치료 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.118-124
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to evaluate the survival and pattern of failure after radiation therapy of sino-nasal cancer using partial attenuation filer and wedged beams and to help radiotherapy planning of sino-nasal cancer. $\underline{Materials\;and\;Methods}$: Between February 1992 and March 2003, 17 patients with sino-nasal cancers underwent radiation therapy using partial attenuation filter at Dongsan Medical Center, Keimyung university. There were 9 male and 8 female patients. Patients' age ranged from 40 to 75 years (median 59 years). There were 10 patients of maxillary sinus cancer, 7 patiens of nasal cancer. The histologic type was squamous cell carcinoma in 11, adenoid cystic carcinoma in 4 and olfactory neuroblastoma in 2. The distribution of clinical stage by the AJCC system was 3 for stage II, 7 for III and 6 for IV. The five patients were treated with radiation alone and 12 patients were treated with surgery and postoperative radiation therapy. The range of total radiation dose delivered to the primary tumor was from 44 to 76 Gy (median 60 Gy). The follow-up period ranged from 3 to 173 months with median of 78 months. $\underline{Results}$: The overall 2 year survival rate and disease free survival rate was 76.4%. The 5 year and 10 year survival rate were 76.4% and 45.6% and the 5 year and 10 year disease free survival rate was 70.6%. The 5 year disease free survival rate by treatment modality was 91.6% for postoperative radiation group and 20% for radiation alone group, statistical significance was found by treatment modality (p=0.006). There were no differences in survival by pathology and stage. There were local failure in 5 patients (29%) but no distant failure and no severe complication required surgical intervention. $\underline{Conclusion}$: Radiation therapy of sino-nasal cancer using partial attenuation filter was safe and effective. Combined modality with conservative surgery and radiation therapy was more advisable to achieve loco-regional control in sino-nasal cancer. Also we considered high precision radiation therapy with dose escalation and development of multi-modality treatment to improve local control and survival rate in advanced sino-nasal cancer.

Homogeneous Dose Planning to Paranasal Sinus with the Partial Attenuation filters and Wedged Beams in 6 MV Photon Beam (6 MV 광자선의 투과성필터와 Wedge 선속을 이용한 부비강의 균등선량계획)

  • Choi, Tae-Jin;Lee, Ho-Joon;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.183-191
    • /
    • 1993
  • The homogeneous dose planning is one of the most important roles in radiation therapy. But, it is not easy to obtain a homogeneous dose to paranasal sinus region including the ethmoidal sinus with conventional irradiation techniques. In this experimental study, the authors tried to get a homogeneous dose at PNS region, but the nasal cartirage does not exceed the tolerance dose, with anterior-posterior beam and two both lateral wedged beams. Used three fields were shielded with full thickness of blocks to preserve the eye-balls and with blocks of one half value layer to create a homogeneous dose at the whole treatment volume. The dose computations are based on the three dimensonal structure with modified scatter contributions of partial shielders and attenuated beams in 6 MV photon beams. The dose distributions of mid-plane is examined with Kodak verification films and teflon-embedded TLD rod (1 mm diameter and 6 mm length) to confirm the computed dose. In our study, the whole PNS regions have shown within $85{\%}$ of the resultant isodose curves with relatively homogeneous dose distribution. The results of dose computation and measurements are agree well within $5{\%}$ uncertainties.

  • PDF

Quantitative Study of Annular Single-Crystal Brain SPECT (원형단일결정을 이용한 SPECT의 정량화 연구)

  • 김희중;김한명;소수길;봉정균;이종두
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.163-173
    • /
    • 1998
  • Nuclear medicine emission computed tomography(ECT) can be very useful to diagnose early stage of neuronal diseases and to measure theraputic results objectively, if we can quantitate energy metabolism, blood flow, biochemical processes, or dopamine receptor and transporter using ECT. However, physical factors including attenuation, scatter, partial volume effect, noise, and reconstruction algorithm make it very difficult to quantitate independent of type of SPECT. In this study, we quantitated the effects of attenuation and scatter using brain SPECT and three-dimensional brain phantom with and without applying their correction methods. Dual energy window method was applied for scatter correction. The photopeak energy window and scatter energy window were set to 140ke${\pm}$10% and 119ke${\pm}$6% and 100% of scatter window data were subtracted from the photopeak window prior to reconstruction. The projection data were reconstructed using Butterworth filter with cutoff frequency of 0.95cycles/cm and order of 10. Attenuation correction was done by Chang's method with attenuation coefficients of 0.12/cm and 0.15/cm for the reconstruction data without scatter correction and with scatter correction, respectively. For quantitation, regions of interest (ROIs) were drawn on the three slices selected at the level of the basal ganglia. Without scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.2 and 2.1, respectively. However, the ratios between basal ganglia and background were very similar for with and without attenuation correction. With scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.69 and 2.64, respectively. These results indicate that the attenuation correction is necessary for the quantitation. When true ratios between basal ganglia and background were 6.58, 4.68, 1.86, the measured ratios with scatter and attenuation correction were 76%, 80%, 82% of their true ratios, respectively. The approximate 20% underestimation could be partially due to the effect of partial volume and reconstruction algorithm which we have not investigated in this study, and partially due to imperfect scatter and attenuation correction methods that we have applied in consideration of clinical applications.

  • PDF

NEW EVALUATION METHODS FOR RADIAL UNIFORMITY IN NEUTRON TRANSMUTATION DOPING

  • Kim, Hak-Sung;Lim, Jae-Yong;Pyeon, Cheol-Ho;Misawa, Tsuyoshi;Shiroya, Seiji;Park, Sang-Jun;Kim, Myong-Seop;Oh, Soo-Youl;Jun, Byung-Jin
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.442-449
    • /
    • 2010
  • Recently, the neutron irradiation for large diameter silicon (Si)-ingots of more than 8" diameter is requested to satisfy the demand for the neutron transmutation doping silicon (NTD-Si). By increasing the Si-ingot diameter, the radial non-uniformity becomes larger due to the neutron attenuation effect, which results in a limit of the feasible diameter of the Si-ingot. The current evaluation method has a certain limit to precisely evaluate the radial uniformity of Si-ingot because the current evaluation method does not consider the effect of the Si-ingot diameter on the radial uniformity. The objective of this study is to propose a new evaluation method of radial uniformity by improving the conventional evaluation approach. To precisely predict the radial uniformity of a Si-ingot with large diameter, numerical verification is conducted through comparison with the measured data and introducing the new evaluation method. A new concept of a gradient is introduced as an alternative approach of radial uniformity evaluation instead of the radial resistivity gradient (RRG) interpretation. Using the new concept of gradient, the normalized reaction rate gradient (NRG) and the surface normalized reaction rate gradient (SNRG) are described. By introducing NRG, the radial uniformity can be evaluated with one certain standard regardless of the ingot diameter and irradiation condition. Furthermore, by introducing SNRG, the uniformity on the Si-ingot surface, which is ignored by RRG and NRG, can be evaluated successfully. Finally, the radial uniformity flattening methods are installed by the stainless steel thermal neutron filter and additional Si-pipe to reduce SNRG.