The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.
International Journal of Fluid Machinery and Systems
/
제3권1호
/
pp.58-66
/
2010
A steam control valve is used to control the flow from the steam generator to the steam turbine in thermal and nuclear power plants. During startup and shutdown of the plant, the steam control valve is operated under a partial flow conditions. In such conditions, the valve opening is small and the pressure deference across the valve is large. As a result, the flow downstream of the valve is composed of separated unsteady transonic jets. Such flow patterns often cause undesirable large unsteady fluid force on the valve head and downstream pipe system. In the present study, various flow patterns are investigated in order to understand the characteristics of the unsteady flow around the valve. Experiments are carried out with simplified two-dimensional valve models. Two-dimensional unsteady flow simulations are conducted in order to understand the experimental results in detail. Scale effects on the flow characteristics are also examined. Results show three types of oscillating flow pattern and three types of static flow patterns.
액체로켓엔진용 연소기 산화제 개폐밸브는 단순 온 오프 개폐작동을 통해 연소기로의 산화제 공급 유무만을 제어하기 때문에, 산화제 공급 유량 조절을 통한 엔진 점화 시동 특성제어 및 최적화에 한계가 있는 반면에 2단계 개방 연소기 산화제 개폐밸브는 밸브의 부분 개방에 의해 산화제 공급 유량을 조절함으로써 엔진 점화 시동 특성을 제어할 수 있는 이점이 있다. 이에 본 논문에서는 액체로켓엔진용 2단계 개방 연소기 산화제 개폐밸브 개발을 위한 기본 설계 내용과 함께 밸브 작동성에 관한 검증시험 결과를 소개하기로 한다.
최근 강화되는 연료소비율과 배기 규제에 대응하기 위해 자동차용 엔진에 다양한 신기술들이 적용되고 있다. 직접분사식 희박연소 엔진은 안정적인 성층혼합기 연소를 통해 연료소비율 및 배출가스 개선이 가능하지만 과잉공기 조건에서 상대적으로 높은 수준은 질소산화물의 배출은 해결되어야 할 과제이다. 본 연구에서는 직접분사식 희박연소 LPG 엔진에서 가변 밸브 기구를 이용한 흡기 및 배기밸브 시기의 변경이 엔진의 성능 및 배출가스에 미치는 영향을 파악하고자 하였다. 스로틀링을 하지 않은 부분부하 운전 조건에서 흡기밸브 열림 시기의 진각은 공기과잉률의 증가에 의한 질소산화물 배출 증가에 원인으로 작용하였다. 배기밸브 열림 시기를 진각할 경우 팽창일 감소와 펌핑손실 증가에 의해 연료 소비율이 악화되었다.
본 연구에서 사용되는 발전기용 커먼레일 디젤엔진은 흡 배기 밸브의 작동을 위해 기계적으로 구동되는 캠축을 이용하고 있으며, 차량 운전조건 알맞게 밸브의 개폐시기가 고정되어 있다. 그러나 발전기용 엔진은 회전속도가 일정하고 부분부하에서 운전된다. 따라서, 발전용 커먼레일 디젤엔진의 최적화 설계를 위해 밸브 타이밍의 변화에 따른 디젤연소와 배출가스의 특성을 고찰하여 연비 측면에서 계산하였다. 디젤엔진의 밸브 타이밍은 흡배기 유동을 변화시킴으로서 연소특성에 영향을 주었으며 발전기의 연비 개선이 가능하다고 판단되었다.
본 연구에서는 특수가스용기용 밸브의 안전성에 관한 실험적 연구를 수행하였다. 시험용 밸브는 특수가스용기에 부착되었던 것을 무작위로 수거한 것으로 가스누출 및 작동 안전성에 대한 시험을 실시하였다. 실험결과에 의하면, 밸브의 몸체, 나사 체결부, 안전판, 방출구, 스템부, 핸들에서 가스누출 안전성에 영향을 미칠 정도의 크랙, 마모, 부식, 변형이 발생하지 않았다. 다만, 핸들의 페인트 일부가 벗겨지고, PT나사와 몸체에서 녹이 국부적으로 형성되어 있지만, 가스누출 안전성에 영향을 미칠 정도는 아니었다. 또한, 탈거한 밸브에서 가스누출은 발생되지 않았다. 다만, 밸브스템의 영구변형과 오링의 마찰표면 일부에서 손상이 관찰되었다. 따라서, 탈거된 밸브의 가스누출 안전성을 보장하기 위해서 밸브시트와 오링 교체하는 것이 바람직함을 알 수 있다. 또한, 핸들의 조임력을 주기적으로 점검하는 것이 필요함을 알 수 있었다.
This study examines whether engine fuel efficiency is improved by optimization of the exhaust valve timing in a state where the intake valve timing has been optimized in a small turbo gasoline engine that has intake cams and exhaust cams with fixed valve opening periods. When the exhaust valve is opened late, the expansion stroke is longer, and the efficiency can be improved. A 2-cylinder turbo gasoline engine with 0.8 liters of displacement and an MPI (Multi Point Injection) fuel system was used. The engine was operated at 1,500 and 3,000 rpm, and the load conditions included a partial load of 50 N·m and a high load of 70 N·m. Data was recorded as the exhaust valve timing was controlled, and this was used to calculate the efficiency of combustion using a heat release, the fuel conversion efficiency, and the pumping loss. Results and the hydrocarbon concentrations in the exhaust gas were compared for each condition. Experiment results confirmed that additional fuel efficiency improvements are possible through exhaust valve timing control at 1,500 rpm and 50 N·m. However, in other operating conditions, fuel efficiency improvements could not be obtained through exhaust valve timing control because cases where the pumping loss and fuel/air mixture slip increased when the exhaust valve timing changed and the fuel efficiency declined.
Congenital coronary artery fistula is a rare condition, and with widespread use of cardiac catheterization, angiography and selective coronary arteriography are being recognized with increasing frequency. Fistula originating from the right coronary artery are more common then those from the left coronary artery. The fistula empties into the right side of the heart in 90% of the cases with the right ventricle being the most common recipient chamber followed by the right atrium and the pulmonary artery. Recently we experienced two cases of congenital coronary artery fistula which originated from the left coronary artery each other. The first case was 17 moth-old-male, who have had the symptoms of frequent URI, dyspnea and continuous murmur in physical examination. The fistulous communication was noted between the left circumflex coronary artery and the right ventricle with aneurysmal dilation of RV wall. The proximal opening of the fistulous tract was directly close with partial aneurysmorrhaphy of RV wall. Also the termination site of fistulous tract in RV chamber was closed. The second case was 35-year-old female, who have had the symptom of exertional dyspnea and continuous murmur in physical examination. The tortuous and dilated fistulous tract was noted between the left anterior descending coronary artery and the pulmonary artery. The proximal opening of the fistula was ligated near the left anterior descending coronary artery with preservation of normal continuity of coronary artery. And the dilated tortuous vessel was excised. Also the terminal site in pulmonary artery was directly closed just above the pulmonic valve. Postoperative hospital courses of two patients were uneventful without any specific complications and discharged without problems.
This paper deals with an empirical model for decoupling control to control the refrigeration system effectively. The conventional control schemes of the system are mainly focused on representative two control methods, superheat control and capacity control. The capacity control is basically conducted to respond partial loading conditions on the purpose of energy saving. The superheat control is mainly carried out to maintain maximum coefficient of performance (COP). In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. The capacity and superheat can not be controlled independently because of interfering loop when the compressor speed and opening angle electronic expansion valve is varied. Therefore, we suggest decoupling model to eliminate the interfering loop at first. Next, each transfer function in decoupling control model is obtained from number of experiments.
The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchanger with R410A. This study carried out experimental and numerical analysis for indoor heat exchangers. In the experimental study, capacity of the indoor unit was estimated 8.3 kWh with the valve opening rate of 95% for the 50% partial operation condition. The air temperatures were measured using 80 thermocouples. This study also compared experimental data with the calculated data for the outlet temperature and the tube length. It is found that the relative errors between the experiment data and the calculated result are 4.2% and 0.5% for the outlet temperature and the tube length, respectively.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.