• 제목/요약/키워드: Partial Correlation

검색결과 1,073건 처리시간 0.026초

광섬유 센서를 이용한 부분방전 측정연구 (A Study on Partial Discharge Measurement using Optical Fiber Sensors)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

유중 부분방전 음향신호의 전달특성 (Propagation Characteristics of Acoustic Signals Produced by Partial Discharges in an Insulation Oil)

  • 박대원;차상욱;조향은;김동건;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.188-188
    • /
    • 2011
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. We fabricated a decoupler and an amplifier to measure acoustic signals produced by PD. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz~1.6 MHz. After a comparative calibration by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil as a function of distance.

  • PDF

초음파 기법에 의한 케이블 접속재 내부파티클 영향 연구 (A Study on the Affection of Conducting Particle in Cable Splice by Ultrasonic Method)

  • 박치영;이동준;권창오;곽희로;송일근;박하용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1853-1855
    • /
    • 1997
  • This paper describes the characteristics of partial discharge generated by conducting particle in cable splice using ultrasonic method. For simulating partial discharges generated by defects, outer semi conductor of cable splice as ring share electrode was used. The conductive particle was attached on the surface of cable insulator(XLPE) to examine the affection of conducting particles in cable splice. The correlation between the partial discharge quantity and the magnitude of the ultrasonic signal was investigated as the number, length, diameter and alignment of particle when applied voltage increased.

  • PDF

태양광 어레이의 출력 특성을 이용한 개선된 전역 최대전력 점 추종 기법 (Improved Global Maximum Power Point Tracking Technique Using Output Characteristics of Solar Array)

  • 유규현;이우철
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.111-117
    • /
    • 2020
  • The photovoltaic module has the characteristic that the output power varies according to the amount of insolation. If partial shading occurs in an environment composed of an array, a number of local maximum power points (LMPPs) may be generated according to the shading state. Photovoltaic arrays require global maximum power point tracking due to variations in output characteristics caused by solar radiation and temperature. Conventional algorithms, such as P&O and Incond, do not follow the global maximum power point in a partial shaded solar array. In this study, we propose a technique to follow the global maximum power point by using the correlation of voltage, current, and power in solar arrays. The proposed control technique 2qw validated through simulation and experiments by constructing a 2-kW solar system.

초음파 신호를 이용한 부분방전 검출 장치 개발에 관한 연구 (Implementation for Partial Discharge Detection using Ultrasonic Signal)

  • 최수안;정형호;곽희로;김재철;정상진;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1993
  • This paper presents a diagnostic technique using ultrasonic for operating power transformer. Two methods are used as a base for detecting a partial discharge. One is a analysis of PD trend using counted ultrasonic signal, the other is a estimation of PD location source using cross-correlation. In this paper we implement detection equipment of partial discharge in power transformer. The desired system is utilized to two methods for PD detection and operated by graphical user interface(GUI). The results of test showed that the system can be adopted to real power transformer.

  • PDF

유치원 유아의 모자간 애착과 어머니의 양육행동 및 유아의 지적발달과의 관계 (The Relationship between Attachment to mother of Kindergarten Children and their mothers' Parenting Behavior and their Cognitive Development)

  • 홍계옥
    • 대한가정학회지
    • /
    • 제32권4호
    • /
    • pp.181-191
    • /
    • 1994
  • The purpose of the present study was to examine the relationship of attachment to their mother of kindergarten children and their mother's parenting behavior and their cognitive development. The subjects were 32 children and their mothers who participated in Hong's study (1993) The instruments were Mother's Child Rearing Questionaire revised by this researcher and Kim's IQ test. The results showed partial significant correlation between mother's parenting behavior and their children's attachment to them. Children's attachment to their mothers has significant correlation to their cognitive development.

  • PDF

Efficient Key Detection Method in the Correlation Electromagnetic Analysis Using Peak Selection Algorithm

  • Kang, You-Sung;Choi, Doo-Ho;Chung, Byung-Ho;Cho, Hyun-Sook;Han, Dong-Guk
    • Journal of Communications and Networks
    • /
    • 제11권6호
    • /
    • pp.556-563
    • /
    • 2009
  • A side channel analysis is a very efficient attack against small devices such as smart cards and wireless sensor nodes. In this paper, we propose an efficient key detection method using a peak selection algorithm in order to find the advanced encryption standard secret key from electromagnetic signals. The proposed method is applied to a correlation electromagnetic analysis (CEMA) attack against a wireless sensor node. Our approach results in increase in the correlation coefficient in comparison with the general CEMA. The experimental results show that the proposed method can efficiently and reliably uncover the entire 128-bit key with a small number of traces, whereas some extant methods can reveal only partial subkeys by using a large number of traces in the same conditions.

METHOD TO REDUCE THE SPURIOUS PEAKS IN THE CROSS-CORRELATION FOR THE PD LOCATING

  • Chung C.S.;Kim, J.C.;Kwak, H.R.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.781-784
    • /
    • 1994
  • Detecting partial discharge(PD) and locating its source are one of many diagnosis methods. Location the PD source is very important to reduce the time and cost of repairing power transformers. And to locate the PD source, the cross-correlation method is a well known one. But there many spurious peaks in cross-correlation, and occasionally, some peaks could be bigger than the true one. In order to analysis these spurious peaks and to reduce them, we have done many experiments and simulations. As the results we could reduce the spurious peaks, and get well defined cross-correlation from which it is easy to locate the PD source accurately.

  • PDF

부분방전 해석 방법으로 PSA(Pulse Sequence Analysis)의 문제점에 대한 고찰 (Some Considerations on the Problems of PSA(Pulse Sequence Analysis) as a Partial Discharge Analysis Method)

  • 김정태;이호근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.327-330
    • /
    • 2004
  • Because of its effectiveness for the PD(partial discharge) pattern recognition, PSA(Pulse Sequence Analysis) has been considered as a new analytic method instead of conventional PRPDA(Phase Resolved Partial Discharge Analysis). However, PSA has a big problem that can misanalyze patterns in case of data missing resulting from poor sensitivity because it analyses the correlation between sequential pulses, which leads to hesitate to apply it to on-site. Therefore, in this paper, the problems of PSA such as data missing and noise adding cases were investigated. For the purpose, PD data obtained from various defects including noise adding data were used and analysed, The result showed that both cases can cause fatal errors in recognizing PD patterns. In case of the data missing, the error depends on the kinds of defect and the degree of degradation. Also, it could be noticed that the error due to adding noises was larger than that due to some data missing.

  • PDF

다양한 결함으로부터 발생되는 절연열화를 검출하기 위한 새로운 접근기법으로써의 카오스 분석 (CHAOTIC ANALYSIS OF PARTIAL DISCHARGE (CAPD) AS A NOVEL APPROACH TO INVESTIGATE INSULATION DEGRADATION CAUSED BY THE VARIOUS DEFECTS)

  • 김성홍;박재준;임윤석;윤정훈;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.221-224
    • /
    • 2001
  • In connection with the monitoring of insulation degradation of large power apparatus in order to predict their unexpected service failures, a statistical treatment, such as phase resolved partial discharge analysis(PRPDA), has been established for the on-line monitoring system during the past decades. However, this method has shown some inconveniences to distinguish the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis(CAPD) is proposed describing the fundamental ideas, outcomes and different view points from conventional PRPDA. In order to make a model for the possible defects causing sudden failures in service, several types of specimen were prepared. And partial discharge signals, originated from those samples, were measured and analysed by means of PRPDA and CAPD respectively. Throughout this paper, it seems that the correlation between the consecutive PD pulses depending on the nature of PD could be investigated by CAPD. Therefore, it could be considered that the nature of PD source can be distinguished more distinctively when the PRPDA is combined with CAPD.