• Title/Summary/Keyword: Park lighting

Search Result 733, Processing Time 0.033 seconds

A Fundamental Study on the Corrention of Image by Different CCT - Using Photoshop CS2 (색온도에 따른 이미지 보정에 관한 기초적 연구 -Photoshop CS2 활용-)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.97-100
    • /
    • 2007
  • Recently, since adjustment systems of various CCT(Correlated Color Temperature) are much developed, lighting environment of indoor has created by such various CCT lighting systems. If an indoor image of fixed CCT will quickly correct images of various CCT, lighting or interior designers can utilize it to persuade his or her clients in the indoor lighting planning process. Therefore, this paper presents fundamental data which are RGB data of seven color images for the correction of image by three different CCT.

  • PDF

Development of a Measurement and Verification Scheme for Efficient Lighting Program (고효율조명기기 프로그램 성과의 계량 및 검증 기법의 개발)

  • Cho, Ki-Seon;Park, Jong-Jin;Rhee, Chang-Ho;Kim, Hoi-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.795-797
    • /
    • 2005
  • This paper describes a measurement & verification scheme for the high efferent lighting program in Demand Side Management (DSM), which was Introduced in the beginning of the 1980's in Korea With the dramatic changes in the circumstance of power industry in Korea. It is required the reviewing for the existing process of DSM programs and the development of the new process methods/standards on the evaluation of DSM programs. To design an accurate evaluation scheme for the high efficient lighting program. In this paper, we develop an evaluation prototype for the high efficient lighting program using measurements and stipulated factors. The proposed scheme is tested by practical measurements and modified stipulated factors Results from the case studios show the proposed scheme could provide the practical performance evaluation results with promising accuracy.

  • PDF

15-4 : Development of an Advanced Double-Sided LCD Using a Single LC Panel and Two Lighting Systems for Mobile Applications

  • Kang, Seung-Gon;Cho, Yong-Ku;Hong, Han-Young;Hwang, Hyun-Ha;Kim, Sung-Ho;Park, Jong- Sool
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.294-297
    • /
    • 2006
  • Using a single LC panel and two lighting systems, we have developed an advanced LCD system called "Double-Sided LCD." It has only one LC panel and two lighting systems, but it can display images of the same size and resolution on both the front and the rear side. Furthermore, utilizing a simple and thin lighting system we have reduced dramatically its module thickness up to 3.0mm, much thinner than that of conventional dual-type LCD, which is quite appropriate for the use of mobile applications.

  • PDF

A Study on the R.G.B LEDs for the Natural Color Realization (R,G,B LED 조명기구를 이용한 Natural Color 구현에 관한 연구)

  • Jung, Yeon-Hong;Kim, Yu-Sin;Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.93-96
    • /
    • 2008
  • Recently, as development of the luminaire industry, many people are interest of the outdoor and indoor lighting environment. Also, as increasing of people activity at night, the role of lighting is more important. In these days, the issue of LEDs lighting environment is using loud colors of LEDs which are the most of primary colors (R, G, B). It is often disliked by same people. Therefore, it is necessary to use of natural color in lighting design using LEDs. The colors of the LEDs are composed of combination of R, G, B diodes. This paper performs to investigate preference of various colors and color patterns of LEDs. The purposes of this study are to suggest standardization and natural colors instead of primary colors using LEDs.

  • PDF

Leakage Current Analysis of 18 kV Lighting Arrester (18kV 배전용 피뢰기의 누설전류 분석)

  • Park, J.N.;Lee, Y.H.;Shin, Y.S.;Su, J.M.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1906-1908
    • /
    • 2002
  • In general, ZnO lighting arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage. In addition, since the resistive leakage current caused by deterioration of ZnO lighting arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. So, in this paper, we presents a leakage current measuring and analysis system of 18[kV] ZnO lighting arrester.

  • PDF

Development of 40W Portable lighting system using ELS (ELS을 이용한 40W lighting system 개발)

  • Kim, Jin-Hong;Park, Joung-Wook;Kim, Gi-Hoon;Cheon, Woo-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.161-164
    • /
    • 2008
  • ELS(Edge Light System)을 이용한 40W조명 시스템을 개발하기 위하여, ELS에 적합한 LED를 선정하고, 색온도 제어라 광색제어를 위한 구동회로 및 제어회를 설계 제각 하였으며, 0.5W R,G,B 4 IN 1 Package 를 적용하여 LED 180EA를 사용하여 LED Lighting System을 개발하였다. ELS LED Lighting System은 40W급 LED SMPS 구동회로 및 광색/색온도 제어회로 설계, 면발광을 위한 ELS 설계, 방열 설계 및 기구 구조 설계를 통하여 개발되었으며, 직접 시제품을 제작하고 그 성능을 측정하였다.

  • PDF

The Study based on Accelerated Degradation Test of General Lighting 4W LED Lamp using External Converter (조명용 4W 컨버터 외장형 LED램프의 가속열화시험평가)

  • Park, Chang-Kyu;Oh, Geun-Tae
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.267-279
    • /
    • 2011
  • LEDs have been used extensively in the mobile device, automobile, and general lighting because they are semi-permanent, long life, less power consumption, reliable and environmentally friendly. In this paper, the accelerated degradation test(ADT) for a general lighting 4W LED Lamp using external converter is considered. The conditions of ADT are high temperature and high humidity. We show that its life time is log-normally distributed with same parameters under both a normal condition and an accelerated condition, and also derive an accelerated factor.

A Case study on Exterior lighting effect of new and reconstruction works at the Station after Beginning Korea Train Express (고속 철도 개통 후 역사 신축 및 증. 개축에 따른 경관 조명 연출 방식에 관한 연구)

  • Seo Myoung-In;Lee In-Hwa;Jang Woo-Jin;Park Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.637-642
    • /
    • 2005
  • April, 2004, Korea Train Express construction project has accomplished and opened over 10 year terms of huge works. This is a case study focused on the Exterior lighting effect of new & reconstruction works at the Central station opened recently, and the lighting display process of the subsidiary facilities. The comparison with the renowned international stations would be provided for the better installation methods. And the result of case study, it will go far toward improving the Lighting display process.

  • PDF

Reliability Assessment Criteria of Power Light Emitting Diodes for Lighting fittings (조명용 Power LED의 신뢰성평가기준)

  • Park, Chang-Kyu;Jeong, Hee-Suk;Jeong, Hai-Sung;Baik, Jai-Wook
    • Journal of Applied Reliability
    • /
    • v.9 no.3
    • /
    • pp.219-231
    • /
    • 2009
  • Power light emitting diodes(LED) for lighting fittings are so much environment-friendly, highly reliable and consume less energy that they are widely used at home and in industries such as electronics, telecommunications and industrial machineries. However, they are exposed to a very diverse environment and consists of complex components and, therefore needs careful approach to the enhancement and assessment of reliability of the item. In this article reliability assessment criteria for LED are established in terms of performance assessment test, reliability assessment test and accelerated test.

  • PDF

Electrical and Optical properties of Xe gas in flat lighting source (제논(Xe) 가스를 사용한 평판형 광원에서의 전기 및 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2190-2192
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF