• Title/Summary/Keyword: Park facility

Search Result 2,304, Processing Time 0.04 seconds

Development of System Repairing & Reinforcing for Irrigation & Draingage Structure (농업기반 수리구조물의 보수보강 공법 시스템 구축)

  • Kim, Kwan-Ho;Park, Kwang-Su;Kim, Myeong-Won;Lee, Joon-Gu;Kim, Han-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.153-156
    • /
    • 2005
  • It is not feasible for agricultural facility managers to estimate how severe damages are and what are causes of them when agricultural hydraulic facilities get damaged for some reasons. Moreover, it is nearly impossible for agricultural facility managers to take immediate actions to repair and reinforce the damaged structures. Thus, there have been needs for well-established systems to help agricultural facility managers understand its severity and causes, and take proper actions to reduce speed of deterioration and to repair/reinforce them. Thus repairing and reinforcing systems of agricultural hydraulic structures based on agricultural facility management policies, developed in this study, can be efficiently used in field works to determine top priority location and the budget of repairing and reinforcing projects if detailed information of damages in concrete structures and damage types are well compiled and classified with standardized image data complemented.

  • PDF

The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility (하나로 유동모의 시험설비의 노심채널 유동분포 해석)

  • Park Y C.;Kim K. R.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF

Develop Test Facility of High Altitude Environment for Kick Motor (Kick Motor용 고공환경 모사 시험 설비 개발)

  • Kim, Sang-Heon;V.A, Bershadskiy;Yu, Byung-Il;Kim, Yong-Wook;Oh, Seung-Hyub;Park, Jeong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.707-710
    • /
    • 2008
  • The method suggested in this thesis is the safe and economic method when testing rocket engine because ground test facility copies high altitude. We have decided to use the schematic of testing facility based on already known design method and test result, and we have decided the test condition for ground firing test of solid fuel. In addition the pressure of nozzle exit area is 0.1bar, we have designed the testing facility structure to test in this condition. Moreover, we have designed to reduce the accident probability.

  • PDF

Development of Short-circuit Testing Facility for Distribution Transformers (배전용 변압기 단락강도 시험설비 개발)

  • Park, Ji-Hun;Min, Yun-Hong;Kang, Young-Hak;You, Ho-Keun;Ahn, Kyu-Sun;Ham, Gil-Ho;Oh, Chang-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.64-67
    • /
    • 2002
  • To increase the short-circuit testing capacity of distribution transformers, testing facility has been installed for KEPCO in Vi-wang. The power supply of testing facility is directly supplied from the network substation located closely. Testing can be performed up to 300 kVA for single-phase transformers, 500 kVA for three-phase transformers. Operating with this facility, the distribution company is able to maintain the reliable supply of electricity. Also the critical quality of transformers from manufacturers can be verified by short-circuit testing. This paper describes the design concept and specification of newly developed equipment and the procedure of short-circuit test.

  • PDF

Development of Reducer for Generating Facility of Electric Power for Low Noise/vibration (소음/진동을 고려한 발전설비용 감속기 개발)

  • Lee, Hyoung-Woo;Park, Chul-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2008
  • A dynamic model of reducer for generating facility of electric pourer having bevel gear pair and planetary gear train is developed by lumped method. The model accounts for the shaft and bearing flexibilities, gyroscopic effects and the force couplings among the transverse and torsion motions due to gearing. Vibration/noise analysis as well as strength of bevel gear pair and planetary gear train are considered. Exciting forces of high reducer for generating facility of electric power areconsidered as the mass unbalance of the rotors, misalignment and a function of gear transmission error. A Campbell diagram, in which the excitation sources caused by the mass unbalance of the rotors, misalignment and the transmitted errors of the gearing are considered, shows that, at the operating speed, there are not critical speed.

Measurements of In-phantom Neutron Flux Distribution at the HANARO BNCT Facility

  • Kim Myong Seop;Park Sang Jun;Jun Byung Jin
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.203-209
    • /
    • 2004
  • In-phantom neutron flux distribution is measured at the HANARO BNCT irradiation facility. The measurements are performed with Au foil and wires. The thermal neutron flux and Cd ratio obtained at the HANARO BNCT facility are $1.19{\times}10^9\;n/cm^{2}s$ and 152, respectively, at 24 MW reactor power. The measured in-phantom neutron flux has a maximum value at a depth of 3 mm in the phantom and then decreases rapidly. The maximum flux is about $25\%$ larger than that of the phantom surface, and the measured value at a depth of 22 mm in the phantom is about a half of the maximum value. In addition, the neutron beam is limited well within the aperture of the neutron collimator. The two-dimensional in-phantom neutron flux distribution is determined. Significant neutron irradiation is observed within 20 mm from the phantom surface. The measured neutron flux distribution can be utilized in irradiation planning for a patient.

Development of system repairing & reinforcing for irrigation & draingage structure (농업기반 수리구조물의 보수보강 공법 시스템 구축)

  • Kim, Kwan-Ho;Park, Kwang-Su;Kim, Myeong-Won;Lee, Joon-Gu;Kim, Han-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.289-292
    • /
    • 2005
  • It is not feasible for agricultural facility managers to estimate how severe damages are and what are causes of them when agricultural hydraulic facilities get damaged for some reasons. Moreover, it is nearly impossible for agricultural facility managers to take immediate actions to repair and reinforce the damaged structures. Thus, there have been needs for well-established systems to help agricultural facility managers understand its severity and causes, and take proper actions to reduce speed of deterioration and to repair/reinforce them. Thus repairing and reinforcing systems of agricultural hydraulic structures based on agricultural facility management policies, developed in this study, can be efficiently used in field works to determine top priority location and the budget of repairing and reinforcing projects if detailed information of damages in concrete structures and damage types are well compiled and classified with standardized image data complemented.

  • PDF

A Study on Residential Facility Based on the Characteristics of Behavior and Motion for People with visual Impairments (주거 공간 계획을 위한 시각장애인의 행위에 따른 동작특성에 관한 연구)

  • Kim, Min-Gyeong;Keum, Yo-Chan;Park, Yong-Hwan
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.2 s.55
    • /
    • pp.99-107
    • /
    • 2006
  • People with visual impairments are difficult to go to education facility by themselves, because of their limited visual ability, orientation, and usability field, so they prefer dormitories. Those dormitories playa role in living space, education, communication and culture function. Therefore those facilities planned more user centered design, since they are influenced by user actability and their values. User centered designs that match between the user and space are understood as well as their characteristics and behavior. Especially for understanding their activity, observation is conducted about their behavior in dormitories. Thus the purpose of this study is suggested to be a basic source that planning about residential facility for people with visual impairments through interview and observation investigation by analysis that they resident in space motion and performance.

A Case Study on the Safety Assessment for Groundwater Pathway in a Near-Surface Radioactive Waste Disposal Facility

  • Park, Joo-Wan;Chang, Keun-Moo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.232-241
    • /
    • 2002
  • A safety assessment is carried out for the near-surface radioactive waste disposal in the reference engineered vault facility. The analysis is mainly divided into two parts. One deals with the release and transport of radionuclide in the vault and unsaturated zone. The other deals with the transport of radionuclide in the saturated zone and radiological impacts to a human group under well drinking water scenario. The parameters for source-term, geosphere and biosphere models are mainly obtained from the site specific data. The results show that the annual effective doses are dominated by long lived, mobile radionuclides and their associated daughters. And it is found that the total effective dose for drinking water is far below the general criteria of regulatory limit for radioactive waste disposal facility.

A Study on the User Satisfaction of Pedestrian Environment in the Underground Public Pedestrian Facility - Focusing on the Yeongnam province - (지하공공보도시설 보행환경의 사용자 만족도연구 - 영남지역 사례를 중심으로 -)

  • Park, Jung-Ho;Choi, Jae-Won;Choi, Young-Oh;Lee, Ho-Young
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.129-134
    • /
    • 2013
  • This study is to search for improvement of Pedestrian Environment through User Satisfaction on Underground Public Pedestrian Facility. Development of large scale underground spaces has been increased by urban multi-dimensional. However, concern for practical users is in lack because the aim of the development is to obtain profit. Thus, this study have tried to find consideration of architectural factors of underground public pedestrian facility in Yeongnam province for pedestrians. Also, the study have tried to find improvement for the architectural factors depending on an evaluation index of pedestrian environment and satisfaction of the practical users.