A development of facility management system providing alarm function for fault effect and replacement of each component (부품별 고장 영향 및 교체 알람을 제공하는 시설물 관리 시스템의 개발)

  • Hwang, Hun-Gyu;Park, Dong-Wook;Park, Jong-Il;Lee, Jang-Se;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.456-462
    • /
    • 2014
  • In this paper, we develop a facility management system which provides fault effect and replacement alarm function of each component for supporting effective maintenance of facility. To do this, we use weighting method to each component, calculate importance of each component, and make them to hierarchy structure using bill of materials of facility. Also, we draw fault cause and fault effect of components based on failure modes effects and criticality analysis, and define criteria of severity, occurrence and detection to get risk priority number. To apply these concepts, we develop and test the facility management system to verify its practicality. In the future, we expect the developed system to apply many domains such as maintenance of ship and offshore plant.

Anomaly Detection System in Mechanical Facility Equipment: Using Long Short-Term Memory Variational Autoencoder (LSTM-VAE를 활용한 기계시설물 장치의 이상 탐지 시스템)

  • Seo, Jaehong;Park, Junsung;Yoo, Joonwoo;Park, Heejun
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.4
    • /
    • pp.581-594
    • /
    • 2021
  • Purpose: The purpose of this study is to compare machine learning models for anomaly detection of mechanical facility equipment and suggest an anomaly detection system for mechanical facility equipment in subway stations. It helps to predict failures and plan the maintenance of facility. Ultimately it aims to improve the quality of facility equipment. Methods: The data collected from Daejeon Metropolitan Rapid Transit Corporation was used in this experiment. The experiment was performed using Python, Scikit-learn, tensorflow 2.0 for preprocessing and machine learning. Also it was conducted in two failure states of the equipment. We compared and analyzed five unsupervised machine learning models focused on model Long Short-Term Memory Variational Autoencoder(LSTM-VAE). Results: In both experiments, change in vibration and current data was observed when there is a defect. When the rotating body failure was happened, the magnitude of vibration has increased but current has decreased. In situation of axis alignment failure, both of vibration and current have increased. In addition, model LSTM-VAE showed superior accuracy than the other four base-line models. Conclusion: According to the results, model LSTM-VAE showed outstanding performance with more than 97% of accuracy in the experiments. Thus, the quality of mechanical facility equipment will be improved if the proposed anomaly detection system is established with this model used.

A Study on Thermal Satisfaction of Domestic Heat Wave Reduction Facilities (국내 폭염 저감 시설의 온열 만족도에 대한 연구)

  • Jun, Yong-Joon;Park, Lyool;Park, Kyung-Soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • As abnormal climates occur due to the increase in greenhouse gases at home and abroad, various problems such as human casualties, crop damage, energy depletion, and economic loss due to heat diseases, which are one of the extreme climate phenomena, are following one after another. In response, the government has established the 'Climate Crisis Response Special Committee' since 2018, when it recorded the greatest damage in history due to heat waves, and has been carrying out budget formation and reform of laws and systems every year to respond to heat waves. However, in relation to the heat wave damage reduction facility that is being expanded with a large budget, there is no prior research related to the degree of heat loss due to the use of the facility, the difference in effects between specific groups, and the economic effect that comes back compared to the invested budget. Therefore, from a midto long-term perspective, it is expected that it will be difficult to establish a clear direction for policy making. Therefore, in this study, representative facilities were selected according to the principle of heat reduction among the currently expanded heat damage reduction facilities, and a questionnaire survey was conducted for users of each reduction facility (waterfall, awning, pond, and elastic pavement). Accordingly, the change in the sense of heat according to the use of the heat damage reduction facility was checked, and the change in the sense of heat according to the group characteristics (gender, age, metabolic rate) was analyzed to examine the characteristics of the relationship between the facility and the users.

A Simple Model for RAM Analysis and Its Application to DUPIC Fuel Fabrication Facility

  • Ko, Won-Il;Park, Jong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.505-510
    • /
    • 1996
  • A simple model for RAM (Reliability, Availability and Maintainability) analysis and its computer code are developed for application to DUPIC fuel fabrication system. The approach is obtained by linking the allocation model (top-down method) to bottom-up method for RAM analysis. As a result, the availability requirement of subsystem, as well as the buffer storage requirement between processes, are evaluated for the DUPIC facility..

  • PDF

Trend Analysis on Facility Monitoring of Korea National Parks (국립공원 시설모니터링 변화추이 분석)

  • Lee, Ju-Hee;Bae, Min-Ki;Sim, Kyu-Won
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.4
    • /
    • pp.487-500
    • /
    • 2010
  • The purpose of this study was to provide direction for national parks management policies by analyzing national park facility monitoring data collected every 2 years from 2002 to 2006. The results of this study showed the following. Firstly, 16 mountainous national parks showed increasing values in importance and performance in IPA. The trend analysis results showed that the location and capacity of parking lots as well as the number of rest rooms need to be improved. Secondly, two marine national parks indicated increasing values in campground and coastal facilities in IP value. Also, the location, number, and cleanliness of rest rooms, safety and surface condition of trail, guard rail and warning signs, information signs, drinking water fountains and shower facilities were priorities for improvement. The implications of this study will be able to help by providing guidelines for installation and maintenance of park facilities which in turn will improve visitor satisfaction and establish national park facility operation policies.

The study on relation between ocular function and accommodative facility (시기능과 조절 용이성과의 관계 연구)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • To assess convergence and accommodation at a short distance, 92 selected subjects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT 10) at a short distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA). BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D flipper. Bernell Co., USA), vergence facility(prism flipper, Bernell Co., USA). There were such test results as MEM retinoscopy(R/L)($+1.05{\pm}0.87/1.02{\pm}0.80$ D). BELL retinoscopy ($17.89{\pm}12.12/17.94{\pm}11.72cm$), binocular accommodative facility (R/G)($7.69{\pm}6.48cpm$). binocular accommodative facility(polaroid)($11.76{\pm}5.22cpm$), monocular accommodative facility(R/L) ($13.9{\pm}6.27/13.8{\pm}5.96cpm$), vergence facility($13.5{\pm}6.40cpm$).

  • PDF

Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Yang, Heejeong;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Construction and Application of Urban Foundation Facility Electronic Library in Ubiquitous Computing Environment (유비쿼터스 시대의 도시기반시설물전자라이브러리 구축 및 활용 방안)

  • Jin, Hai-Ming;Kim, Byung-Guk;Sung, Jung-Gon;Park, In-Man
    • Journal of Korea Spatial Information System Society
    • /
    • v.8 no.3
    • /
    • pp.27-37
    • /
    • 2006
  • It defined the standard list of the urban foundation facility which from the local self-government it is managing with commonness and standard items and standard option and a construction plan it drew up "Urban Foundation Facility Electronic Library" it researched. "Urban Foundation Facility Electronic Library" defines with the aggregate of the component DB which lets to collect the organization, quality and form of the urban Foundation facility back attribute item system from the Geographic Information System(GIS). Consequently after the "Urban Foundation Facility Electronic Library" is constructed, it presented the application plan from on-the-spot inspection. Also it applied in the ubiquitous environment which is actualized quickly the plan which it does in the RFID and sensor network and electronic library grafting it presented. The connection use of the RFID and was possible from the Facility civil official test which applies the RFID.