• Title/Summary/Keyword: Park cooling

Search Result 1,846, Processing Time 0.032 seconds

Fluid Inclusion Studies of the Fluorite Deposits in Korea (우리나라 형석광상(螢石鑛床)의 유체포유물(流體包有物) 연구(硏究))

  • Park, Hee In
    • Economic and Environmental Geology
    • /
    • v.9 no.1
    • /
    • pp.27-43
    • /
    • 1976
  • The flourite in Hwacheon, Hwanggangri and Keumsan district are major fluorite producing areas in Korea. The fluorite deposits of Hwacheon district are wholly fissure filling hydrothermal veins embedded in Precambrian gneiss and schists and Jurassic granites. Also some fluorite deposits are emplaced in felsite whose age is unknown. Emplacement of most fluorite veins of the district are controlled by EW fracture system. Fluorites are generally accompanied to chalcedonic quartz and also kaolinite, montmorillonite, dickite and calcite in parts. Vertical and lateral mineral zonings are not distinct. The fluorite deposits in the Hwanggangri district are wholly embedded in limestone and other calcareous sediments of Paleozoic Yeongweol Group. Most of the fluorite deposits belong to one of two categories which are steeply. dipping veins and gently dipping replacement deposits adjacent to Late Cretaceous(83-90mys) granite bodies. The strikes of fluorite veins of Hwanggangri district mostly occupy the fractures of $N30^{\circ}-40^{\circ}E$ and $N30^{\circ}-40^{\circ}W$ system. Fluorites are accompanied to calcite, milky quartz, chalcedonic quartz, and also montmorillonite, kaolinite in parts. But in some deposits, scheelite, various sulfide minerals and barite are accompanied. Emplacement of fluorite deposits are largely controlled by lithology and structures of this district. In some deposits fluorite veins gradate to scheelite veins and also telescoping of the mineral zones are found in this district. In the Keumsan district, fissure-filled fluorite veins and replacement deposits are mostly emplaced in limestone of Paleozoic Yeongweol Group, late Cretaceous quartz-porphyry, granite and sandstone. Some deposits are emplaced in Precambrian metasediments. Mineralogy and other characteristics of the deposits in this district is similar to those of Hwanggangri district. Fluid inclusion studies reveal the difference of salinities, $CO_2$ contents of ore fluid and temperatures during fluorite mineral deposition in the these districts. In Hwacheon district, ore-fluids were comparatively dilute brine and low $CO_2$ content. Filling temperatures ranges $104^{\circ}C$ to $170^{\circ}C$. In the Chuncheonshinpo mine, most deeply exploited one in this district, salinitles range 0.5-2. 2wt. % NaCl and filling temperatures range from $116^{\circ}C$ to $143^{\circ}C$. In the Hwanggangri district, ore fluids were complex and filling temperature ranges very widly. In the contact metasomatic fluorite deposits, ore fluid were NaCl rich brines with moderate $CO_2$ content and filling temperatures range from $285^{\circ}C$ to above $360^{\circ}C$. Fluids inclusions in tungsten and sulfide minerals bearing fluorite veins show high $CO_2$ content up to 31wt. %. Filling temperature ranges from $101^{\circ}C$ to $310^{\circ}C$. Fluids inclusions In mainly fluorite bearing veins were more dilute brine and low $CO_2$ contents. Filling temperatures range from $95^{\circ}C$ to $312^{\circ}C$. Filling temperature of fluid inclusions of Keumsan district are between $95^{\circ}C$ and $237^{\circ}C$. Data gathered from geologic, mineralogic and fluid inclusion studies reveal that fluorite mineralization in H wacheon district proceeded at low temperature with dilute brine and low $CO_2$ content. In Hwangganri district, fluorite mineralization proceeded by several pulse of chemically distinct ore fluids and formed the mineralogically different type of deposits around cooling granite pluton which emplaced comparatively shallow depth.

  • PDF

Physicochemical Properties of Starch in Water Chestnut (Eleocharis kuroguwai Ohwi) (올방개 괴경 전분의 이화학적 특성)

  • Kim, Sang-Kuk;Shin, Jong-Hee;Kim, Su-Yong;Kim, Hak-Yoon;Park, Shin-Young
    • Korean Journal of Weed Science
    • /
    • v.32 no.3
    • /
    • pp.204-210
    • /
    • 2012
  • The physicochemical properties of tuber starch in water chestnut have been studied. Peak viscosity, hot paste viscosity and cooling peak viscosity were 5679, 3146 and 4262 RVU, respectively. In three transition parameters, onset temperature ($T_o$), peak temperature ($T_p$), and conclusion temperature ($T_c$) were 64.1, 68.5 and $72.3^{\circ}C$, respectively. Gelatinization enthalpy (${\Delta}H$ gel) was 4.48 J/g. A-type starch has a smaller proportion (11.4%) of short chains ($DP{\geq}12$) and a larger proportion (57.2%) of short chains ($13{\leq}DP{\geq}24$). The tuber starch of water chestnut displayed an A-type X-ray diffraction pattern showing a strong diffraction peak at $2{\Theta}$ values of $15.18^{\circ}$, $17.13^{\circ}$, and $23.1^{\circ}$, and a weak peak at $2{\Theta}$ values of $18.1^{\circ}$, $20.06^{\circ}$, and $26.69^{\circ}$. Their crystallinity was 28.6% and the mean starch granule size was 21.5 ${\mu}m$.

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.

Petrologic and Mineralogic Studies on the Origin of Paleolithic Obsidian Implements from Wolseongdong, Korea (월성동 구석기 유적 출토 흑요석제 석기의 암석 및 광물학적 연구를 통한 원산지 추정)

  • Jang, Yun-Deuk;Park, Tae-Yoon;Lee, Sang-Mok;Kim, Jeong-Jin
    • Journal of the Korean earth science society
    • /
    • v.28 no.6
    • /
    • pp.733-742
    • /
    • 2007
  • Petrological, mineralogical, and geochemical analyses were carried on the paleolithic obsidian implements excavated at Wolseongdong, Daegu, Korea. The obsidians has a homogeneous glassy texture that can be observed in a typical obsidian formed from a rapid cooling of silicic magma. Major element composition of the obsidians represent calc-alkaline series. Comparing those with other obsidians from domestic local excavation sites, Mt. Baekdu, and Kyusu of Japan, the Wolseongdong obsidians show similar element distribution pattern with others in spite of small difference in trace and rare Earth element contents. Sr isotopes of the obsidians considerably differ from those of the obsidians from southern part of the Korean Peninsula or from Mt. Baekdu. K-Ar age is approximately 30 Ma, which is much older than Mt. Baekdu (10 Ma). Therefore, considering the characteristics of obsidians found in the Korean Peninsula including mineralogy, petrology, trace element, and isotopes chronology, the obsidians can be divided into four groups: Mt. Baekdu, southern part of Korea (Kyusu of Japan), middle part of Korea, and Wolseongdong region. These groups suggest a possibility of more than four different origins of the obsidians found in the Korean Peninsular.

Evaluation of Residual Radiation and Radioactivity Level of TRIGA Mark-II, III Research Reactor Facilities for Safe Decommissioning (TRIGA Mark-II, III 연구로 시절의 폐로를 위한 시설의 잔류 방사선/능 평가)

  • Lee, B.J.;Chang, S.Y.;Park, S.K.;Jung, W.S.;Jung, K.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.109-120
    • /
    • 1999
  • Residual radiation and radioactivity level in TRIGA Mark-II, III research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, have been measured, analyzed and evaluated to know the current status of radiation and radioactivity level and to establish and to provide the technical requirements for the safe decommissioning of the facilities which shall be applied in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. Radiation dose rate and surface radioactivity contamination level on the experimental equipments, floors, walls of the facilities, and the surface of the activated materials within the reactor pool structure were measured and evaluated. Radioactivity and radionuclides in the pool and cooling water were also analyzed. In case of the activated reactor pool structures which are very difficult to measure the radiation and radioactivity level, a computer code Fispin was additionally used for estimation of the residual radioactivity and radionuclides. The radiation and radioactivity data obtained in this study were effectively used as basic data for decontamination and dismantling plan for safe decommissioning of TRIGA Mark-II, III facilities.

  • PDF

A Survey of Preference for Commercial Makgeolli among Chinese Students in Korea (국내 시판 막걸리에 대한 중국인 유학생의 기호도 조사)

  • Jeon, Ki-Suk;Park, Shin-In
    • Culinary science and hospitality research
    • /
    • v.20 no.4
    • /
    • pp.115-126
    • /
    • 2014
  • The purpose of this study was to offer primary information for development of Makgeolli adapted to the tastes of Chinese and marketing strategies for promoting consumption of Makgeolli in the Chinese market. This study was intended to investigate the Makgeolli drinking behavior through a survey and the sensory properties and preference of fresh and sterilized Makgeolli through sensory evaluation focusing on the Chinese students in Korea, becoming potential consumers of Makgeolli. The survey was conducted from October 9th to October 30th, 2013, and then 117 copies were adopted for the analyses. The results are as follows. 71.8% of the subjects liked Makgeolli, 56.4% drank 5-6 times a week, and 25.7% drank more than 2 bottles at a time. 61.5% of the subjects had purchasing experience. The routes of collecting information about Makgeolli were acquaintances(66.7%) and media sources(28.2%). In the sensory evaluation, sterilized Makgeolli(BS) that has a fresh odor, sweet and sour taste, cooling sensation, and good aftertaste got the best score in the overall acceptability, and fresh Makgeolli(KD) that has a strong nuruk odor, turbidity, bitter taste, and heavy mouthfeel got the lowest score in the overall acceptability. These results show that sweet, fresh, and refreshing Makgeolli suits Chinese's taste and word of mouth marketing through the expansion of tasting events would promote Makgeolli consumption in the Chinese market.

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.