• 제목/요약/키워드: Park Wan-Seo

검색결과 405건 처리시간 0.029초

톳 자숙액 에탄올 추출물의 항산화 활성 (Antioxidant Activity on Ethanol Extract from Boiled-water of Hizikia fusiformis)

  • 박기의;장미순;임치원;김연계;서영완;박희연
    • Applied Biological Chemistry
    • /
    • 제48권4호
    • /
    • pp.435-439
    • /
    • 2005
  • Antioxidant activity of the ethanol extract from boiled-water of Hizikia fusiformis (EBH) were compared with those of BHA, L-ascorbic acid, gallic acid, caffeic acid and (-)-catechin. The free radical scavenging ability against DPPH (1,1-diphenyl-2-picrylhydrazyl), authentic peroxynitrite and reducing power were measured as indices of antioxidant activity. EBH showed the potent DPPH radical and peroxynitrite scavenging activities, showing 85.23 and 96.97% at final concentration of $1000{\mu}g/ml$, respectively. The reducing power increased with the increasing amount of EBH (final concentration of 1, 10, 100 and $1000{\mu}g/ml$). Total phenolic content of EBH was 588 mg (-)-catechin/g at the final concentration $1000{\mu}g/ml$. Total phenolic contents correlated with DPPH radical scavenging activity $(R^2=0.766)$ and reducing power $(R^2=0.944)$. These results suggested that EBH could be a natural antioxidative source containing antioxidative components.

PCR Based Detection of Phellinus linteus using Specific Primers Generated from Universal Rice Primer(URP) Derived PCR Polymorphic Band

  • Kang, Hee-Wan;Park, Dong-Suk;Park, Young-Jin;Lee, Byoung-Moo;Cho, Soo-Muk;Kim, Ki-Tae;Seo, Geon-Sik;Go, Seung-Joo
    • Mycobiology
    • /
    • 제30권4호
    • /
    • pp.202-207
    • /
    • 2002
  • This study was carried out to develop specific primers for PCR detection of Phellinus linteus. Diverse genomes of 15 Phellinus spp. including five Phellinus linteus isolates were fingerprinted by Primer Universal rice primer(URP)1F. The URP-PCR pattern differentiated P. linteus isolates from other phellinus spp. A polymorphic band(2.8 kb), which is unique for P. linteus isolates, was isolated and sequenced. Twenty four-oligonucleotide primer pairs were designed based on information of DNA sequence. The primer set(PLSPF2/PLSPR1) amplified single band(2.2 kb) of expected size with genomic DNA from seven Phellinus linteus, but not with that of other Phellinus species tested. The primers could be used identically in both DNA samples from mycelium and fruit bodies. This specific primers could offer a useful tool for detecting and identifying P. linteus rapidly.

단일편파 레이더자료 품질관리기술 특성 분석 (Analysis of Quality Control Technique Characteristics on Single Polarization Radar Data)

  • 박소라;김헌애;차주완;박종서;한혜영
    • 대기
    • /
    • 제24권1호
    • /
    • pp.77-87
    • /
    • 2014
  • The radar reflectivity is significantly affected by ground clutter, beam blockage, anomalous propagation (AP), birds, insects, chaff, etc. The quality of radar reflectivity is very important in quantitative precipitation estimation. Therefore, Weather Radar Center (WRC) of Korea Meteorological Administration (KMA) employed two quality control algorithms: 1) Open Radar Product Generator (ORPG) and 2) fuzzy quality control algorithm to improve quality of radar reflectivity. In this study, an occurrence of AP echoes and the performance of both quality control algorithms are investigated. Consequently, AP echoes frequently occur during the spring and fall seasons. Moreover, while the ORPG QC algorithm has the merit of removing non-precipitation echoes, such as AP echoes, it also removes weak rain echoes and snow echoes. In contrast, the fuzzy QC algorithm has the advantage of preserving snow echoes and weak rain echoes, but it eliminates the partial area of the contaminated echo, including the AP echoes.

LB법에 의한 제막된 poly(3-hexylthiophene)의 발광특성 (Emitting Properties of Poly(3-hexylthiophene) deposited by LB method)

  • 서부완;김주승;구할본;이경섭;박복기;박계춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.962-964
    • /
    • 1999
  • We studied emitting properties of devices fabricated using the spin-coating and Langmuir-Blodgett[LB] technique. The LB technique has the advantage of precise control of the thickness better than spin-coating method. Poly(3-hexylthiophene)[P3HT] LB films used as the emitting layer in light-emitting devices. LB monolayers were deposited 27 layers onto the indium-tin-oxide[ITO] as Y-type films by the vertical dipping method. The thickness is about 80nm. Absorption spectrum of LB films presented that P3HT is regiorandom conformation. Also, current-voltage-luminance characteristics and electroluminescence spectra of light-emitting devices fabricated by LB method is studied. In current-voltage-luminescence characteristics, turn-on voltage of P3HT LB film LEDs is higher than that of spin-coating LEDs. But electroluminescence spectrum is similar to the spin-coating LEDs. The orange-red light was clearly visible in a darkened room.

  • PDF

C12A7계 슬래그와 석유 코크스 연소재를 사용한 수축저감재 및 모르타르의 특성 (Properties of Shrinkage Reducing Agent and Mortar with C12A7-based Slag and Petroleum Cokes Ash)

  • 추용식;박수현;서성관;박재완
    • 한국세라믹학회지
    • /
    • 제50권5호
    • /
    • pp.319-325
    • /
    • 2013
  • In this study, petroleum cokes ash and $C_{12}A_7$-based slag were used for the shrinkage reduction and strength enhancement of mortar. The hydration properties of shrinkage reduction agents were analysed. The flow, change of length and compressive strength were experimented with mortar-added shrinkage reduction agents. As a result of this study, petroleum cokes ash : $C_{12}A_7$-based slag = 60~80% : 20~40% showed excellent results. In the case of mortar with 20% $C_{12}A_7$-based slag, the setting time and change of length were similar to Ref. mortar. The flow and compressive strength were superior to Ref. mortar. In the case of mortar with a 40% $C_{12}A_7$-based slag, the setting time was longer than Ref. mortar. The compressive strength of 3 days and 7 days were superior to Ref. mortar.

교량 건설 문서의 강화된 XML 스키마 매칭을 위한 인공신경망 기반의 요소 가중치 선정 방안 (Artificial Neural Network-based Weight Factor Determination Method for the Enhanced XML Schema Matching of Bridge Engineering Documents)

  • 박상일;권태호;박준원;서경완;윤영철
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.41-48
    • /
    • 2022
  • Bridge engineering documents have essential contents that must be referenced continuously throughout a structure's entire life cycle, but research related to the quality of the contents is still lacking. XML schema matching is an excellent technique to improve the quality of stored data; however, it takes excessive computing time when applied to documents with many contents and a deep hierarchical structure, such as bridge engineering documents. Moreover, it requires a manual parametric study for matching elements' weight factors, maintaining a high matching accuracy. This study proposes an efficient weight-factor determination method based on an artificial neural network (ANN) model using the simplified XML schema-matching method proposed in a previous research to reduce the computing time. The ANN model was generated and verified using 580 data of document properties, weight factors, and matching accuracy. The proposed ANN-based schema-matching method showed superiority in terms of accuracy and efficiency compared with the previous study on XML schema matching for bridge engineering documents.

박막필터형 4- 채널 파장분할 다중화 소자의 제작 및 평가 (Fabrication and Evaluation of Thin Film Filter Type 4-Channel Wavelength Division Multiplexing Device)

  • 박경현;서완석;정영만;박희갑;마동성;강민호
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.400-407
    • /
    • 1987
  • Thin film filter type 4-channel wavelength division multiplexing(WDM) device was designed and fabricated for the application in optical subscriber loop system. It has multi-mode fiber pigtails and four wavelength division consisting of 0.81, 0.89, 1.2 and 1.3 um. The evaluated performances are 1-2d B of insertion loss(connector loss excluded)and 30-35d B of crosstalk attenuation for all channels. The performance of the fabricated device was tested in the wideband optical transmission experiment, where the SNR degradation due to the crosstalk of the device was found to be within a measurement error.

  • PDF

뇌졸중 환자의 보행시간에 대한 현 신호체계 분석 (Analysis of Current Traffic Signals for Pedestrians according to the Walking Times of Stroke Patients)

  • 이동진;나은예;박선미;박세진;박엘림;박완서;배우리;백화신;서경태;서동현;안승우
    • 대한임상전기생리학회지
    • /
    • 제10권2호
    • /
    • pp.7-14
    • /
    • 2012
  • Purpose : This study investigated the validity of crosswalk signal time length with regards to elderly stroke patients. Methods : We recruited 60 elderly adults sixty years of age or older for our study. The participants were divided into three groups.Group A consisted of 20 healthy participants with no walking aids. Group B consisted of 20 stroke patients with no walking aids. Group C consisted of 20 stroke patients using a cane as a walking aid. We measured the walking times of participants for 7 m, 14 m and 21 m lengths. Results : Using an independent t test, there was a statistically significant difference in the walking times between Group A and Group B for all lengths. There was a statistically significant difference in the walking times between Group A and Group C for all lengths. There was no statistically significant difference in the walking times between Group B and Group C. There was a statistically significant difference between the three group when using ANOVA. Conclusion : From the results of this study, we infer that the signal times at crosswalks are inappropriate for elderly stroke participants who use a cane as a walking aid. Therefore further research should be conducted to determine the appropriate amount of additional time needed for the elderly to safely cross the street.

혈우병 소견을 가진 뇌출혈 환자 치험(治驗) 1례(例) (Clinical study on 1 case of Cerebral hemorrhage patient with hemophilia)

  • 정인태;서병관;이현종;하지영;강미경;홍장무;백용현;박동석;최도영
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.237-244
    • /
    • 2003
  • Objective : Hemophilia, a genetically determined disorder, is characterized by abnormality of the coagulation mechanism due to functional deficiency of a specific factor, namely VIII or IX. In this study, the effect of Dong-Si acupuncture therapy on the cerebral hemorrhage patient with hemophilia was evaluated. Methods : We treated him with acupuncture by stimulating Dong-Si acupuncture point(Yuk Wan) and assessed the effect by using manual dynamic evaluation of MRC(Medical Research Council) and Modified Barthel Index. Results : After treatment, the bleeding tendency was grossly reduced and bleeding lesion was absorbed gradually. And manual dynamic evaluation of the upper extremity increased from 4 grade to 5 grade. Conclusions : This result suggest that Dong-Si acupuncture therapy on the cerebral hemorrhage patient with hemophilia was effective. And futher studies are required to concretely prove the effectiveness of Dong-Si acupuncture therapy for treating hemorrhagic diseases.

  • PDF

타일형 프로젝터를 이용한 저주파 능동 반향음 감소 기법 (Low-Frequency Active Echo Reduction Using a Tile Projector)

  • 이재완;우상범;장하다;이근상;김완구;강휘석;엄원석;박영철;윤석왕;서영수
    • 한국음향학회지
    • /
    • 제33권6호
    • /
    • pp.366-374
    • /
    • 2014
  • 저주파 능동 소나를 이용한 잠수함 탐지 기술이 개발됨에 따라, 기존의 수동 무반향 타일을 대치할 새로운 잠수함 스텔스 기술이 요구되는 추세이다. 본 연구에서는 선체 표면과 같은 대면적에 적용 가능한 타일형 프로젝터를 이용하여 능동 임피던스 정합을 구현함으로써 저주파 반향음 감소를 도모하는 기법을 제안한다. 먼저 능동 임피던스 정합 기법의 기술적 타당성을 확인하기 위하여 유한요소 모델을 이용한 저주파 반향음 감소 시뮬레이션을 수행하였다. 이를 바탕으로 타일형 프로젝터를 설계 및 제작하여 음향수조에서 저주파 반향음 감소 실험을 수행하였다.