• Title/Summary/Keyword: Park Disk

Search Result 1,035, Processing Time 0.031 seconds

Analysis of a Novel MR Rotary Brake with Permanent Magnet (영구자석을 이용한 새로운 MR 브레이크의 해석)

  • Yun, Dong-Won;Park, Jung-Ho;Son, Young-Su;Park, Hee-Chang;Park, Cheol-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.1
    • /
    • pp.34-41
    • /
    • 2009
  • In this paper, a novel MR brake with permanent magnet is developed. This system consists of rotary disk, permanent magnet, spring and MR fluid. Permanent magnets are attached to the rotary disk and moves in the direction of radius. The magnets are linked to rotor axis by spring. As rotation speed increases, the magnets move outward from the center of the system by centrifugal force in the MR fluid. A proper design of stator or case makes the system have unique torque characteristics. The research is performed like following procedures. First, the electromagnetic characteristic of the system is analyzed using Maxwell. Next, torque is calculated using the results of the electromagnetic analysis. Finally, the performance of various types of the brake systems are investigated and compared with each other.

Analysis of Dynamic Characteristics on the L/UL Ramp Using Advanced FE Model (FE모델을 사용하여 램프상의 로드-언로드 동적특성에 대한 해석)

  • Jung, Moon-Gyo;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.413-418
    • /
    • 2004
  • Recently, the development of mobile devices demands information storage systems to use micro drive devices. 1-inch micro drive hard disk uses the load/unload(L/UL) technology to increase area recording density and reduce power consumption. Because micro drive has light actuator, effects of the flexible cable that is ignored in 3.5-inch hard disk drive is important to load/unload performances. In this paper, effects of flexible cable on load/unload performances are studied.

  • PDF

Improved Velocity Control in Ramp Load/Unload HDD (램프 로드/언로드 HDD에서의 향상된 속도 제어)

  • Song, Yeon-Chul;Park, Sung-Won;Jeong, Jun;Park, Tae-Wook;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.586-591
    • /
    • 2004
  • A load/unload mechanism is applied to most small form factor hard disk drives. Loading velocity is ones of the most important factors to ensure the reliability of the load/unload operations. Especially, the lower the flying height of the head becomes, the more important the accuracy of the loading velocity control becomes. Because there is no sensor during the load/unload operations, BEMF voltage is used to sense the head velocity. To measure BEMF voltage, a simple circuit is added to the load/unload HDD control system. Overall acceptable results are obtained by using the simple PI controller but the errors from the target velocity occur when the head moves along the ramp and then reaches the disk. Feedforward profile and disturbance observer are used to remove those errors effectively.

  • PDF

Comparison of static MRI and pseudo-dynamic MRI in tempromandibular joint disorder patients (측두하악관절장애 환자에서의 static MRI와 pseudo-dynamic MRI의 비교연구)

  • Lee, Jin-Ho;Yun, Kyoung-In;Park, In-Woo;Choi, Hang-Moon;Park, Moon-Soo
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.199-206
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. Materials and Methods: In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. Results: No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P<0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). Conclusion: This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  • PDF

A Study on the Separation and Extraction of Polycyclic Aromatic Hydrocarbons in Water Sample by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석법에 의한 물시료 중 Polycyclic Aromatic Hydrocarbons의 분리 및 추출에 관한 연구)

  • Lee, Won;Hong, Jee-Eun;Park, Song-Ja;Pyo, Hee Soo;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.321-331
    • /
    • 1998
  • The separation and sample extraction methods of 19 polycyclic aromatic hydrocarbons (PAHs) in water samples were investigated by gas chromatography/mass spectrometry (GC/MS) and some extraction methods involved liquid-liquid extraction, disk extraction and solid-phase extraction methods. The separation of 19 PAHs was possible by partial variation of oven temperature of GC/MS in temperature range $80{\sim}310^{\circ}C$. Extraction procedures of PAHs in water samples were somewhat modified and compared as extraction recoveries and the simplicity of methods. Extraction recoveries of PAHs were 71.3~109.5% by liquid-liquid extraction method. By using disk extraction, good extraction recoveries (80.7~94.9%) were obtained in case of $C_{18}$ disk extraction method by filtration. And extraction recoveries of PAHs by $C_{18}$ solid-phase were in the range of 51.8~77.9%. Method detection limits (S/N=5) of 19 PAHs were in the range of 0.25~6.25 ppb by liquid-liquid extraction and solid-phase extraction and 0.05~1.25 ppb by disk extraction methods.

  • PDF

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF