• 제목/요약/키워드: Paramagnetic

검색결과 358건 처리시간 0.029초

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

상자성 풋쉬플메이서의 반전화 (On Inversion Rations for Push-Pull Paramagnetic Masers)

  • 조철
    • 전기의세계
    • /
    • 제21권3호
    • /
    • pp.53-56
    • /
    • 1972
  • Electron paramagnetic resonance is one of the concrete forms of magnetic resonance and the superposition of an external magnetic field causes an orientation of the magnetic moment of an atom. On the assumption that both pumped levels be saturated and all relaxation times equal the inversion ratio for a push-pull paramagnetic maser is obtained and compared with those of three-level paramagnetic masers and the magnetic field intensities for 9 and 10 Gc push-pull ruby maser oriented with an angle of 54.deg.44' between the caxis and the magnetic field are, also, obtained.

  • PDF

Study on multi-stage magnetic separation device for paramagnetic materials operated in low magnetic fields

  • F. Mishima;Aoi Nagahama;N. Nomura;S. Nishijima
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.13-17
    • /
    • 2023
  • Magnetic separation technology for small paramagnetic particles has been desired for the volume reduction of contaminated soil from the Fukushima nuclear power plant accident and for the separation of scale and crud from nuclear power plants. However, the magnetic separation for paramagnetic particles requires a superconducting high gradient magnetic separation system applied, hence expanding the bore diameter of the magnets is necessary for mass processing and the initial and running costs would be enormous. The use of high magnetic fields makes safe onsite operation difficult, and there is an industrial need to increase the magnetic separation efficiency for paramagnetic particles in as low a magnetic field as possible. Therefore, we have been developing a magnetic separation system combined with a selection tube, which can separate small paramagnetic particles in a low magnetic field. In the previous technique we developed, a certain range of particle size was classified, and the classified particles were captured by magnetic separation. In this new approach, the fluid control method has been improved in order to the selectively classify particles of various diameters by using a multi-stage selection tube. The soil classification using a multi-stage selection tube was studied by calculation and experiment, and good results were obtained. In this paper, we report the effectiveness of the multi-stage selection tube was examined.

Electron Paramagnetic Resonance Study of Al-incorporated ZnO:Mn Diluted Magnetic Semiconductors

  • Park, Jun Kue;Lee, K.W.;Choi, D.M.;Lee, Cheol Eui
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1884-1888
    • /
    • 2018
  • We have employed electron paramagnetic resonance spectroscopy and magnetization measurements in order to study the effect of Al-incorporation on the magnetic interactions in ZnO:Mn diluted magnetic semiconductors. Al-doping is shown to decrease the antiferromagnetic correlation and to increase the ferromagnetic interaction, which is attributed to the hydrogen-mediated ferromagnetic Mn complexes in our Mn-doped ZnO samples.

MR조영제와 분자영상 (MR Contrast Agents and Molecular Imaging)

  • 문우경
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

Retrospective dosimetry using fingernail electron paramagnetic resonance response

  • Noori, Abbas;Mostajaboddavati, Mojtaba;Ziaie, Farhood
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.526-530
    • /
    • 2018
  • Human fingernails were used to estimate the radiation dose via electron paramagnetic resonance measurements of radiation-induced radicals. The limiting factors in this research were mechanically induced electron paramagnetic resonance signals due to the mechanical stress during the preparation of the samples. Therefore, different treatment methods of fingernails were used to reduce the mechanically induced signals. The results demonstrate that the mechanically induced and radiation-induced signals have apparently different microwave power saturation behaviors. In addition, the mechanically induced signal shows a fading evolution over time and reaches a constant value. Chemical treatment using the different reagents showed that the minimum mechanically induced signal was obtained using the dithiothreitol reagent. The dose-response curves of the samples treated with dithiothreitol for 30 minutes demonstrated a greater linearity than those of samples treated for 5 minutes. Therefore, to find an unknown absorbed dose in a fingernail sample using a calibration curve, we recommend adopting the mentioned chemical treatment procedure to reduce the uncertainty.

Electron Paramagnetic Resonance of the I2-Doped PBMPV Conducting Polymers

  • Lee, C. H.;Lee, Cheol-Eui;J.-I. Jin;S.-J. Chung
    • Journal of Magnetics
    • /
    • 제2권4호
    • /
    • pp.123-125
    • /
    • 1997
  • We have studied a series of I2-doped poly [2-buthoxy-5-methoxy-1, 4-phenylenevinylene] (PBMPV) conducting polymers by means of electron paramagnetic resonance (EPR) measurements. In this work, the EPR linewidth and spin density were obtained from the EPR intensity and studied as a function of the degree of doping.

  • PDF

Rapid Mapping of Active Site of KSI by Paramagnetic NMR

  • Joe, Yong-Nam;Cha, Hyung-Jin;Lee, Hyeong-Ju;Choi, Kwan-Yong;Lee, Hee-Cheon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권9호
    • /
    • pp.2981-2984
    • /
    • 2012
  • Active site mapping has been done for ${\Delta}^5$-3-ketosteroid isomerase (KSI) by analyses of paramagnetic effect on $^1H-^{15}N$ HSQC spectra using 4-hydroxyl-2,2,6,6-tetramethylpiperidinyl-1-oxy (HyTEMPO) and an intermediate analog (equilenin). Our result revealed that residues in hydrophobic cavity of KSI, particularly active site region, mainly experienced a high line-broadening effect of NMR signal with HyTEMPO, while they experienced full recovery of a lineshape upon the addition of equilenin. The mapped region was very similar to the active site of KSI as described by the crystal structure. These observations indicate that a combined use of paramagnetic reagent and substrate (or analog) could rapidly identify the residues in potential active site of KSI, and can be applied to the analysis of both active site and function in unknown protein.