• Title/Summary/Keyword: Paralleling technique

Search Result 29, Processing Time 0.031 seconds

A Comparative Study on Rate of Error with Bisecting Angle Technique and Paralleling Technique (등각촬영법과 평행촬영법에서의 실책 비교 연구)

  • Lee, Kyeong-Hee;Park, Il-Soon;Jung, Jung-Ock
    • Journal of dental hygiene science
    • /
    • v.11 no.3
    • /
    • pp.155-161
    • /
    • 2011
  • The purpose of this study was to obtain data necessary for guiding students in the future by grasping which rate of error is made how much depending on a shooting technique in the filming of periapical radiograph. 14,402 films, which were instructed targeting students for the Department of Dental Hygiene at D Health College and S Health College, were analyzed. The following results were obtained by conducting questionnaire survey targeting 263 students who completed the shooting practice lesson of bisecting angle technique and paralleling technique. 1. In case of having shot with bisecting angle technique, the ratio of error was the highest in both maxillary and mandibular first molar. 2. In case of having shot with paralleling technique, the ratio of error was the highest in the maxillary bicuspid and the mandibular first molar. 3. As for ratio of error in light of a shooting technique, both bisecting angle technique and paralleling technique were indicated to be the highest in inaccuracy of film position. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 4. As for ratio of error in light of the processing technique, both bisecting angle technique and paralleling technique were indicated to be the highest in dark image and light image. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 5. Students were indicated to feel it to be most difficult for grasping the processing level in the film-developing process. As the above results, to reduce ratio of error given the periapical radiography, a method of reducing ratio of error given the periapical radiography is considered to be what correctly understands the morphological and anatomical structure inside the mouth and what acquires the shooting technique by filming several times with having enough time.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Comparison of the Rate of Error with the Bisecting Angle Technique and the Paralleling Technique (등각촬영법과 평행촬영법에 따른 실책율 비교)

  • Lee, Yeong-Ae;Jo, Min-jung
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.97-102
    • /
    • 2004
  • In order to find out the rate of error according to intraoral standard radiographic techniques, this study analyzed 3,251 standard films, and conducted a questionnaire with 120 Daegu Health College students who have used the bisecting angle technique and the paralleling technique. Followed are the results of the study: 1. The rate of error was the highest in canine from both maxilla and mandible when used by the bisecting angle technique. 2. The rate of error was the highest in premolar from both maxilla and mandible when used by the paralleling technique. 3. The technical error was occurred most frequently in elongation. 4. The rate of error and distortion was higher in the bisecting angle technique than in the paralleling technique. 5. The processing error was occurred most frequently in light film. 6. In applying radiographic techniques, the subjects indicated that the vertical angulation of central radiation in the bisecting angle technique and the oral fixation of film holder in the paralleling technique were the most difficult.

  • PDF

SKIN ABSORBED DOSES FROM FULL MOUTH STANDARD INTRAORAL RADIOGRAPHY IN BISECTING ANGLE AND PARALLELING TECHNIQUES (각이등분법 및 평행법에 의한 전악 구내 표준 촬영시 두경부 피부 흡수선량 비교)

  • Kim Ae-Ji;Nah Kyung-Soo;Doh Shi-Hong;Kim Hyun-Ja;Yoo Meong-Jin
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.315-333
    • /
    • 1990
  • This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography (l4 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator(60㎜ in diameter, 20㎝ in length) and rectangular collimator(35㎜ × 44㎜, 40㎝ in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rates of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling techniuqe, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  • PDF

A survey study on recognition of periapical radiography in dental hygiene students (치위생과 학생의 치근단 촬영법 인식에 관한 조사 연구)

  • Park, Il-Soon;Jung, Jung-Ock;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.5
    • /
    • pp.987-997
    • /
    • 2012
  • Objectives : This study was carried out in order to obtain basic data for students' efficient acquirement and instruction of radiography technology in the future by surveying dental hygiene students' recognition of periapical radiography. Methods : This study carried out a questionnaire survey targeting dental hygiene students from December 2009 to December 2010, and obtained the following results. Results : 1. As a result of examining recognition on periapical radiography, the bisecting angle technique was indicated to be averagely $3.84{\pm}0.566$ points. The paralleling technique was indicated to be $2.66{\pm}0.701$ points. 2. As a result of examining about problems given the bisecting angle technique, what had been most difficult given the bisecting angle technique was indicated to be the highest in cone positioning with 34.2%. The most difficulty given deciding on the X-ray vertical-angel irradiation direction was indicated to be the highest with 66.9% in adjusting the cone direction on the virtual bisector. 3. As a result of examining about problems given the paralleling technique, what had been most difficult in the process of the paralleling technique was indicated to be the highest with 56.7% in fixing the film immobilization device inside the mouth. Conclusions : Examining the above results, it is considered that there is a need of understanding morphological and anatomical structure inside the mouth in order to reduce the mistake rate given the periapical radiography, and that it is important to increase skill level by repetitively shooting several times with having enough time.

TECHNICAL ERRORS IN COMPLETE MOUTH RADIOGRAPHIC SURVEYS ACCORDING TO RADIOGRAPHIC TECHNIQUES AND FILM HOLDING METHODS (구내전악표준방사선사진 촬영시 촬영법과 필름유지법에 따른 촬영상의 실책)

  • Choi Karp-Shik;Byun Chong-Soo;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.103-112
    • /
    • 1986
  • The purpose of this study was to investigate the numbers and causes of retakes in 300 complete mouth radiographic surveys made by 75 senior dental students. According to radiographic techniques and film holding methods, they were divided into 4 groups: Group Ⅰ: Bisecting-angle technique with patient's fingers. Group Ⅱ: Bisecting-angle technique with Rinn Snap-A-Ray device. Group Ⅲ: Paralleling technique with Rinn XCP instrument (short cone) Group Ⅳ: Paralleling technique with Rinn XCP instrument (long cone) The most frequent cause of retakes, the most frequent tooth area examined, of retakes and average number of retakes per complete mouth survey were evaluated. The obtained results were as follows: Group Ⅰ: Incorrect film placement(47.8%), upper canine region, and 0.89 Group Ⅱ: Incorrect film placement (44.0%), upper molar region, and 1.12. Group Ⅲ: Incorrect film placement (79.2%), upper molar region, and 2.05 Group Ⅳ: Incorrect film placement (67.7%), upper molar region, and 1.69. The average number of retakes per complete mouth survey of paralleling technique (Group Ⅲ+Ⅳ) was higher than that of bisecting-angle technique (Group Ⅰ + Ⅱ) (p<0.01). There was no difference between Group Ⅰ and Group Ⅱ, and between Group Ⅲ and Group Ⅳ in the average number of retakes per complete mouth survey (p>0.05).

  • PDF

Dental Hygienists' Perception of the Usefulness of Clinic Practice Training (임상실습 내용 및 활동의 유용성에 대한 치과위생사의 인식)

  • Jang, Gye-Won;Kang, Yong-Ju;Won, Boak-Yeon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.6 no.3
    • /
    • pp.203-218
    • /
    • 2006
  • The purpose of this study was to measure dental hygienists' perception of the usefulness of clinical practice training. A total of 195 dental hygienists participated in the study. The findings of the study were analyzed according to age, the type of hospitals where respondents were working, experience in clinical practices and educational level as follows: 1. There were statistically significant differences in perception of the usefulness of the practice of amalgam filling preparation performed for dental operation among subjects at different ages (p<.01). 2. There were statistically significant differences in perception of the usefulness of the practice of paralleling technique(p<.001), the practice of amalgam filling preparation(p<.01) and the practice of trauma treatment preparation(p<.05) among subjects working at different clinics 3. Significant differences were observed in perception of the usefulness of the practice of sterilization(p<.05), the practice of suction(p<.05), the practice of history taking preparation (p<.01) and the practice of halitosis patient management preparation(p<.05) among subjects with different years of experience in clinical practices. 4. Significant differences were found in perception of the usefulness of the practice of paralleling technique among subjects with different education levels. The findings of the study suggest the need for strengthening education programs for clinical training content and practices which subjects considered important for their job. At the same time, the study emphasizes the need for developing training programs designed to produce dental hygiene preceptor who can provide dental hygienists with practical clinical training in cooperation with college and dental clinics.

  • PDF

COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY (전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구)

  • Kang Mi-Ae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

Analysis of oral radiography practice (구강방사선 실습내용에 관한 분석)

  • Ahn, Geum-Sun;Kim, Hyo-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.5
    • /
    • pp.783-790
    • /
    • 2011
  • Objectives : The purpose of this study was to examine students' difficulties in the process of oral radiography practice, to raise awareness of the importance and necessity of oral radiography and decipher, and to provide some information on effective ways of oral radiography practice. Methods : The subjects in this study were 285 dental hygiene students at K college, who included 153 sophomores and 132 graduates-to-be from June to November, 2010. Results : 1. The parts of the anatomy structure that they found it most difficult to decipher were maxillary molar(25.3%) and lower molar(22.1%). 2. They made during oral radiography was an improper film positioning(35.1%). 3. The part of bisecting technique was adjusting vertical and horizontal angles(53.0%). 4. The part of paralleling technique was positioning XCP in the oral cavity(44.2%). 5. The part of bite-wing technique was adjusting vertical and horizontal angles(38.2%). 6. The part of occlusion technique was positioning film and tube head(36.5%). 7. The part of panorama technique was finding out program setting(42.5%). Conclusions : The findings of the study indicated that in terms of anatomy structure decipher, it's especially difficult to decipher maxillary molar and lower molar, and that film positioning was difficult to do in the process of oral radiography. What difficulties they faced in applying each kind of oral radiography techniques and which part of the oral cavity they found it hard to radiograph were analyzed as well in this study. Given the findings of the study, more intensive practice is required to help students to acquire accurate oral radiography techniques to ensure their successful job performance in the future.

A Study of phase controlled rectifier design of excitation system for thermal power plant (화력발전소 여자시스템 위상제어 정류기 설계에 관한 연구)

  • Lee, J.H.;Ryu, H.S.;Lim, I.H.;Song, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1015-1017
    • /
    • 2002
  • This is the study on static excitation system of synchronous generator of large capacity in new model, which was developed by KEPRI using triple redundant digital method, associate three bridges of thyristor phase controlled rectifier. This paper will discuss the design conception and the application results of system which includes the power control devices(thyristors, GTO) and power excitation potential transformer. The multi-paralleling thyristor bridge converters of N+1 method have firing circuit. The initial product manufactured by proposed design in the study is in commercial operation, completing installation and commissioning in 400MW Thermal Power Plant. The performance test is done in practical technique.

  • PDF