• Title/Summary/Keyword: Parallel-series feed

Search Result 15, Processing Time 0.024 seconds

Precise Modeling and Adaptive Feed-Forward Decoupling of Unified Power Quality Conditioners

  • Wang, Yingpin;Obwoya, Rubangakene Thomas;Li, Zhibo;Li, Gongjie;Qu, Yi;Shi, Zeyu;Zhang, Feng;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.519-528
    • /
    • 2019
  • The unified power quality conditioner (UPQC) is an effective custom power device that is used at the point of common coupling to protect loads from voltage and current-related PQ issues. Currently, most researchers have studied series unit and parallel unit models and an idealized transformer model. However, the interactions of the series and parallel converters in AC-link are difficult to analyze. This study utilizes an equivalent transformer model to accomplish an electric connection of series and parallel converters in the AC-link and to establishes a precise unified mathematical model of the UPQC. The strong coupling interactions of series and parallel units are analyzed, and they show a remarkable dependence on the excitation impedance of transformers. Afterward, a feed-forward decoupling method based on a unified model that contains the uncertainty components of the load impedance is applied. Thus, this study presents an adaptive method to estimate load impedance. Furthermore, simulation and experimental results verify the accuracy of the proposed modeling and decoupling algorithm.

Input Series-Output Parallel Connected Converter Configuration for High Voltage Power Conversion Applications

  • Kim, Jung-Won;You, J.S.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.201-205
    • /
    • 1998
  • In this paper, the charge control with the input voltage feed forward is proposed for the input series-output parallel connected converter configuration for high voltage power conversion applications. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input-series connected modules for all operating conditions including the transients. It also offers the robustness for the component value mismatches among the modules.

  • PDF

Corporate-Series Fed Microstrip Array Antenna with Yagi Elements for 5G

  • Kim, Geun-Sik;Choi, Dong-You
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.3
    • /
    • pp.162-166
    • /
    • 2020
  • The present paper presents an array antenna of a microstrip patch for 5G applications. Four rectangular microstrip patch elements are arranged in parallel and series to form an array antenna. Two insets are made on both sides of each patch element to achieve a wide frequency bandwidth of 23.97-31.60 GHz. To attain a high gain and wider bandwidth, the microstrip patch antenna is fed using series and corporate feeding networks. Further, three director elements on top of the top-most patch elements, and one reflector element at the open end of each patch element, are added. The addition of the Yagi elements improved the overall gain and acquired a higher radiation efficiency throughout the operating frequency bandwidth, with the array antenna achieving a maximum peak gain of 8.7 dB. The proposed antenna is built on a low-loss and low-cost substrate of FR4-eproxy. The proposed antenna design with a simple structure is suitable for Internet of Things and 5G applications.

Integrative Control of Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction (전원 불평형과 역률을 보상하는 직렬형 능동전력필터의 통합적 제어)

  • Jang, Jeong-Ik;Seok, Jul-Ki;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.5
    • /
    • pp.258-264
    • /
    • 2006
  • This paper presents an integrative control scheme for series-type active power filters combined with shunt passive filters not only to compensate for the source voltage unbalance and current harmonics but also to correct the power factor. To reduce the power capacity of the active filters, passive filters are connected in parallel. Diode rectifiers are replaced by the PWM converters in order to feed the real power back to the source. Power factor control is performed by changing the phase of the load voltage so that the phase of the source current coincides with that of the source voltage. The resultant voltage reference is the addition of the voltage component compensating for the source voltage unbalance and harmonic currents and the voltage component correcting the power factor. The validity of the proposed algorithm has been verified by experimental results.

Small Broadband Rectangular Disk-Loaded Monopole Antenna with Electromagnetically Coupled Feed (전자기적 결합 급전 소형 광대역 사각 디스크-로디드 모노폴 안테나)

  • 정종호;박익모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.7
    • /
    • pp.653-660
    • /
    • 2004
  • This paper presents monopole antenna with electromagnetically coupled feed and its equivalent circuit model. The proposed structure is consists of a rectangular disk-loaded monopole and a probe with rectangular spiral strip line feed. The rectangular disk-loaded monopole is represented by parallel RLC resonant circuit and the probe with rectangular spiral strip line feed is represented by series RLC resonant circuit. Therefore broad bandwidth can be achieved through electromagnetic coupling between these structures that generate two resonances within close frequency range. The antenna with electrical dimensions of only 0.075λ$\sub$0/${\times}$0.075λ$\sub$0/${\times}$0.075λ$\sub$0/ has 16.5 % fractional bandwidth for VSWR$\leq$2 at a center frequency of 2.038GHz.

Study on the Effect of Membrane Module Configuration on Pervaporative Performance through Model Simulation (모델모사를 이용한 막모듈 연결 및 배열이 투과증발 막성능에 끼치는 영향에 관한 연구)

  • Yeom, Choong-Kyun;Yoon, Seok-Bok;Park, You-In
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.294-305
    • /
    • 2008
  • This study was focused on the investigation of the effects of membrane module configuration and the temperature of feed retentate flowing along with module length on membrane performance through model simulation. A simulation model of pervaporative dehydration through membrane module assemble in which a number of unit modules are connected in parallel or in series has been established. In this study, ethanol/water mixture was used as model mixture. Some of permeation parameters in the model were quantified directly from the real dehydration pervaporation of ethanol through a lab-made membrane. By adopting the coefficients determined empirically the simulation model could be of more practical value. The simulation of pervaporation with two basic module configurations, that is, parallel connection and series connection, could present the importance of process parameters such as feed rate, module connection mode, number of stages, and inter-stage heating.

System dynamics of scanning tunneling microscope unit

  • Yamada, Hikaru;Endo, Toshiro;Tsunetaka-Sumomogi;Fujita, Toshizo;Morita, Seizo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.794-797
    • /
    • 1988
  • G. Binnig and H. Rohrer introduced the Scanning Tunneling Microscope (STM) in 1982 and developed it into a powerful and not to be missed physical tool. Scanning tunneling Microscopy is a real space surface imaging method with the atomic or subatomic resolution in all three dimensions. The tip is scanned over the surface by two piezo translators mounted parallel (X-piezo and Y-piezo) to the surface and perpendicular to each other. The voltage applied to the third piezo (Z-piezo) translator mounted perpendicular to the surface to maintain the tunneling current through the gap at a constant level reflects then the topography of the surface. The feed back control loop for the constant gap current is designed using the automatic control technique. In the designing process of the feed back loop, the identification of the gap dynamics is very complex and has difficulty. In this research, using some suitable test signals, the system dynamics of the gap including the Z-piezo are investigated. Especially, in this paper, a system model is proposed for the gap and Z-piezo series system. Indicial response is used to find out the model. The driving voltage of the Z-piezo and the tunneling current are considered as input and output signals respectively.

  • PDF

Design of a Circular Polarization Microstrip $12\times12$ Series-Parallel Array Antenna at 10 GHz (원형 편파 마이크로스트립 $12\times12$ 직-병렬 배열 안테나 설계)

  • 이영주;정명숙;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.26-36
    • /
    • 2000
  • A circularly polarized $12\times12$ array with application in the satellite communications is designed at 10 GHz. The radiator is an aperture-coupled ring patch, which is suitable of large arrays. The element spacing of the array is chosen to be $0.7\lambda_0$to maintain the main beam in the broadside direction. The array is a sequential array constructed on a series-parallel feed network to obtain high gain and low axial ratio. Measurement results for the array, acquired by experiments in the compact range of POSTECH, showed a directivity of 27.88 dB, a high gain of 25.55 dB, an efficiency of 60%, an axial ratio of 1.74 dB, and a side-lobe level of -13 dB. The bandwidth of the array was 43% when the VSWR was 2, and the bandwidth of the axial ratio was 16%.

  • PDF

Design of an Aperture-Coupled Dual Beam Microstrip Array Antenna (개구면 결합 급전 방식의 이중 빔 마이크로스트립 배열 안테나의 설계)

  • 이영주;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.738-746
    • /
    • 1999
  • In this paper, a microstrip $18\times2$ dual beam array antenna is designed at 10 GHz. The radiating element is an aperture-coupled patch, and it is analyzed by the transmission line model. The feed is a tapered parallel-series type to reduce the side lobe level. To obtain dual beam at $\pm45^{\circ}$, The difference in phase excitation between the elements is $180^{\circ}$. In conclusion, the side lobe level is 25 dB, and the beam width $8^{\circ}$with two main lobes at $\pm44.5^{\circ}$.

  • PDF

Study on the Fly-back Topology of New Power Feed-back Method for Active Cell Balancing (엑티브 셀 밸런싱을 위한 새로운 전력 피드백 방식의 플라이백 토폴로지에 관한 연구)

  • Seong-Yong Kang;Myeong-Jin Song;Seong-Mi Park;Sung-Jun Park;Jae-Ha Ko
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1083-1095
    • /
    • 2023
  • Recently, the demand for low-voltage, high-capacity ESS is rapidly increasing due to the revitalization of the e-mobility industry, which is mainly powered by electricity. In addition, the demand for portable power banks is rapidly increasing due to the revitalization of leisure industries such as camping and fishing. The ESS with this structure consists of a small number of series cells and many parallel cells, resulting in a system with a large rated current. Therefore, the number of power devices for cell balancing configured in series is small, but a balancing device with a large current capacity is required. Construction of a constant temperature device in such a low-voltage, high-current ESS is difficult due to economic issues. The demand for an active balancing system that can solve the passive balancing heating problem is rapidly increasing. In this paper, propose a power feedback fly-back topology that can solve the balancing heating problem. The characteristic of the proposed topology is that a series-connected voltage sharing voltage is used as the input of the flyback converter, and the converter output is connected to one transformer. In this structure, the converter output for cell voltage balancing shares magnetic flux through one high-frequency transformer, so the cell voltage connected to the converter automatically converges to the same voltage.