• Title/Summary/Keyword: Parallel-feeding

Search Result 74, Processing Time 0.038 seconds

The comparison and investigation of power supply capability according to feeding schemes in AC electric railway system (교류전기철도시스템에서 급전계통 구성에 따른 급전성능 비교검토)

  • Lee, Chang-Mu;Oh, Kwang-Hae;Chang, Sang-Hun;Han, Mun-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1236-1238
    • /
    • 2001
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the collection voltage of train and supplying power from railway substation are greatly unlike. For simulation of collection voltage and power supply according to feeding scheme, using 6-port network analysis proposed previously simulate collection voltage and supply power according to feeding scheme(Parallel Post feeding system, normal feeding system and tie feeding system) and compare and investigate each characteristics.

  • PDF

Evaluation of the variable TAB Autotransformer for ascending collecting Voltage (집전전압 향상을 위한 가변탭 단권변압기 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

Recent Studies of Laser Metal 3D Deposition with Wire Feeding (와이어 송급 레이저 금속 3차원 적층 연구동향)

  • Kam, Dong-Hyuck;Kim, Young-Min;Kim, Cheolhee
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • Recent developments of Laser metal 3D deposition with wire feeding are reviewed which provide an alternative to powder feeding method. The wire feeding direction, angle and position as well as laser power, wire feeding rate, and deposition speed are found to be key parameters to make quality deposition with high throughput. When compared with the powder feed, the wire feed shows higher material efficiency, higher deposition rate, and smoother surface. Large elongated columnar grains which have epitaxial growth across deposit layers are observed in deposit cross sections. The growth direction is parallel to the thermal gradient during the deposit process. Tensile properties are found to be dependent on the direction due to the anisotropic deposit property. A real-time feedback control is demonstrated to be effective to improve the deposition stability.

A Band Pass Filter with Feeding Structure Using π-Type Transmission Line (π-형 전송선 급전 구조를 갖는 대역 통과 필터)

  • Bae, Ju-Seok;Lim, Jong-Sik;Kim, Kwi-Soo;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.114-120
    • /
    • 2008
  • This paper proposed the band pass filter(BPF) with feeding structure using $\pi$-type transmission line by means of transforming the input/output coupled-lines of the half wavelength parallel coupled-line BPF into K-inverter, then substituting $\pi$-type transmission line equivalence for K-inverter. The proposed method supplies solution with what the half wavelength parallel coupled-line BPF's input/output coupled-lines are realized. Also it can quite reduce efforts and time needed to optimize filter performance when is compared to reported method using tapped line structure because formulas is very simple and accurate. On the basic of the proposed method, the BPF with feeding structure using $\pi$-type transmission line has been designed and fabricated. The validity of proposed method was proven by the measured result.

EFFECT OF TIME AFTER FEEDING ON DISTRIBUTION OF DIGESTA IN THE GASTRO-INTESTINAL TRACTS OF SHEEP

  • Sekine, J.;Oura, R.;Miyazaki, H.;Okamoto, M.;Asahida, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.99-102
    • /
    • 1991
  • To determine effect of time after feeding on distribution of digesta in the gastro-intestinal tracts of sheep given orchardgrass hay once a day, a total of fifteen ewes (mean live weight $51{\pm}12kg$) were slaughtered at 2, 8, 16 and 24 hours after feeding. Contents in the reticulo-rumen, omasum, abomasums, small intestine, cecum, and colon and rectum were totally collected and weighed. Weights of digesta in the reticulo-rumen were about 6 kg which contributed about 75% of the total in the whole tracts. Digesta on dry-matter basis totaled about 1 kg. The dry-matter concentration of digesta in the whole digestive tract was about 107 h/kg of fresh digesta. Distribution of moisture in the digestive tract changed in parallel with that of fresh digesta. There was no significant correlation observed between time after feeding and weights of digesta in the gastro-intestinal tracts. While, feed intake significantly correlated with digesta in the reticulo-rumen, cecum and whole tracts (p<0.01). Thus, time after feeding was inferred to have no influence upon the content of digesta in the digestive tract, but feed intake influenced on the content of digesta in the digestive tract at a low level of feeding.

Average Current Control for Parallel Connected Converters

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1153-1161
    • /
    • 2019
  • A current sharing controller is proposed in this paper for parallel-connected converters. The proposed controller is based on the calculation of the magnitudes of system current space vectors. Good current distribution between parallel converters is achieved with only one Proportional-Integral (PI) compensator. The proposed controller is analyzed and the circulating current impedance is derived for paralleled systems. The performance of the new control strategy is experimentally verified using two parallel connected converters employing Space Vector Pulse Width Modulation (SVPWM) feeding a passive RL load and a 2.2 kW three-phase induction motor load. The obtained test results show a reduction in the current imbalance ratio between the converters in the experimental setup from 53.9% to only 0.2% with the induction motor load.

A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System (국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구)

  • Kim, Hyun-Dong;Cho, Gyu-Jung;Huh, Seung-Hoon;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

Examination of Increasing Power Delivery Capacity with variable Tab Autotransformer (가변탭 변압기를 사용한 급전용량 증가 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Lee, Han-Min;Kim, Ju-Rak;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1163_1164
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing train number, electric load at feeding system are increasing and collecting voltage of train are going down. To increase electric load and collecting voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

The comparison and investigation of harmonic magnification according to power supply schemes in high speed railway (고속철도의 급전계통 구성에 따른 고조파 확대율 비교 검토)

  • Lee, Chang-Mu;Oh, Kwang-Hae;Chang, Sang-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1402-1404
    • /
    • 2000
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the harmonic current flowing into the railway substation are greatly unlike. For simulation of harmonic magnification flowing into the railway substation according to feeding scheme, we propose 6-port network analysis method based on 4-port network, find 6-port equivalent model of each circuit component, and compare and investigate harmonic magnification in the case of parallel post and normal feeding scheme.

  • PDF

The Grinding Machining Characteristics of $ZrO_2$ Ceramics Ferrule in the Chucking Alignment Error (척킹 평형 정렬 오차에 따른 지르코니아 세라믹스 페룰의 연삭 가공 특성)

  • Lee S.W.;Kim G.H.;Choi Y.J.;Choi H.Z.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • As the optical communication industry is developed, the demand of optical communication part is increasing. $ZrO_2$ ceramic ferrule is very important part which can determines the transmission efficiency and information quality to connect the optical fibers. In general $ZrO_2$ ceramic ferrule is manufactured by grinding process because the demands precision is very high. And the co-axle grinding process of $ZrO_2$ ceramic ferrule is to make its concentricity all of uniform before centerless grinding. When co-axle grinding of ferrule supported by two pin, pin chucking alignment accuracy is very important. This paper deals with the analysis of the chucking alignment experiment with parallel error on the micro feeding equipment. Thus, if possible be finding highly good the chucking alignment of two pin.

  • PDF