• 제목/요약/키워드: Parallel-feeder

검색결과 15건 처리시간 0.018초

지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구 (Analysis of Harmonic Effects on Substation Power System and its Countermeasure)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

주기적인 슬릿을 갖고 유전체층으로 덮힌 평행평판 도파관에서의 누설파 복사 및 표면파 launching (Leaky Wave Radiation and Surface Wave Launching Problem in a Dielectrically Covered Periodically Slitted Parallel-Plate Waveguide)

  • 이종익;이철훈;조영기
    • 전자공학회논문지D
    • /
    • 제36D권4호
    • /
    • pp.25-33
    • /
    • 1999
  • 유전체로 덮혀 있고 주기적인 슬릿을 갖는 평행평판 도파관에서의 누설파 복사 및 표면과 TEM파가 입사되는 경우에 대하여 고려하였다. 모멘트 방법을 이용하여 무한한 주기적인 구조와 유한한 주기적인 구조를 해석하였다. 유전체 커버가 슬릿을 갖는 누설파 안터나의 성능에 미치는 영향을 보이기 위하여 유전체의 두께에 대한 도파관 내부에서의 반사전력과 투과전력, 자유공간으로의 복사효율, 유전체슬램으로의 표면파 launching 효율, 안테나 이득, 그리고 복사패턴 등의 수치해석결과들을 제시하였다. 또한 제안된 주기적인 구조를 이용한 표면파 lauching 효율의 개선방법을 기술하엿으며 최대효율은 이론적으로 97.5%에 이르렀다. 따라서 이 구조는 image 도파관이나 유전체 격자 안테나의 효과적인 급전기로서 유망하리라 사료된다.

  • PDF

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

랫드에서 매미눈꽃동충하초, Paecilomyces sinclairii의 13주 반복투여 독성에 관한 연구 (Thirteen-Week Repeated Oral Toxicity Study of Paecilomyces sinclairii in Sprague-Dawely Rats)

  • 안미영;지상덕;김지영;한재웅;이용기;이용우;류강선;이병무;정나진;김성남
    • Toxicological Research
    • /
    • 제20권4호
    • /
    • pp.339-348
    • /
    • 2004
  • Paecilomyces sinclairii was administered ad libitum feeding at percentage levels of 0, 1.25, 2.5, 5 and 10 percentage (calculated about 8 g/kg)/feeder for a period of 3 months. There was no observed clinical signs or deaths related to treatment in all groups tested. Therefore, the approximate lethal dose of P. sinclairii was considered to be higher than 8 g/kg in rats. Mild decreases in body weight gain were observed dose-dependently in P. sinclairii treated groups in dose response manner after 2 weeks. Interestingly, the weight of abdominal adipose tissues surrounding epididymides were greatly reduced by this Dongchunghacho, in parallel with the mild increase in body weight gain. However, the absolute weight change of other organs was not observed. There were not significantly different from the control group in urinalysis, ocular examination, hematological, serum biochemical value and histopathological examination. From these results, it is concluded that the no-observed-adverse-effect level (NOAEL) of P. sinclairii is less than 1.25% (1 g/kg) in rats in the present study.

선로전압조정장치(SVR)가 설치된 고압배전선로에서 전기저장장치(ESS)의 최적운용 및 적정용량 산정방안 (Optimal Operation Method and Capacity of Energy Storage System(ESS) in Primary Feeders with Step Voltage Regulator(SVR))

  • 김병기;유경상;김대진;장문석;고희상;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.9-20
    • /
    • 2018
  • 최근 국가의 3020정책에 따라 신재생에너지전원의 도입이 활발히 이루어지고 있는 상황이다. 하지만 신재생에너지전원중의 하나인 태양광전원이 대규모로 배전계통에 도입되어 운용될 경우, 태양광전원의 간헐적 특성에 의한 출력변동과 역조류에 의하여 수용가 전압은 규정범위($220V{\pm}6%$)를 벗어날 수 있는 문제점을 가지고 있다. 이를 해결하기 위한 방안 중 하나로, 배전선로에 기설된 선로전압조정장치를 이용한 수용가 전압조정 방안이 제안되고 있으나, 기계적으로 동작하는 선로 전압조정장치의 특성으로 인하여, 탭 변경 시간동안 수용가의 전압이 규정범위를 벗어날 가능성을 가지고 있다. 이에 본 논문에서는 선로전압조정장치 탭 변경시, 기계적인 특성에 의하여 탭 동작이 지연되는 시간동안 전기저장장치를 도입하여 전압 문제를 해결할 수 있는 전기저장장치의 최적운용전략을 제시하고, 파라메타 분석법을 이용하여 선로전압조정장치와 협조하여 운용되는 전기저장장치의 적정위치 및 적정용량 산정방안을 제안하였다. 본 논문에서 제안한 선로전압장치와 전기저장장치의 상호동작에 대한 최적운용 전략과 전기저장장치의 산정 알고리즘을 바탕으로 시뮬레이션을 수행한 결과, 선로전압조정 장치의 탭 변경 시간동안 수용가의 규정전압($220V{\pm}6%$) 여부를 검증함으로써, 본 논문에서 제안한 수법이 계통의 전압안정화에 기여할 수 있는 방안임을 확인하였다.