• Title/Summary/Keyword: Parallel transformer

Search Result 224, Processing Time 0.024 seconds

Agent based algorithm for detecting sympathetic inrush of a transformer (Agent 기반 변압기의 Sympathetic inrush 판단 방법)

  • Kang, Yong-Cheol;Lee, Byung-Eun;Park, Jong-Min;Hwang, Tae-Keun;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.234-235
    • /
    • 2006
  • The protection relay keeps electric power facilities by using signals of the voltage and current which are input and output terminals of each equipment. Each relay performances protection algorithm by using informations of own protecting zone. To prevent the mal-operation in inrush current, established transformer differential protection method uses the second harmonics as blocking signal. This method is not operate at the initial inrush. However, in case of the parallel operation, if the initial inrush is occurred in one transformer which is generated, the sympathetic inrush Is occurred in adjacent transformer. This paper approach the sympathetic inrush detecting algorithm of a transformer based on agent. Proposed algorithm, when inrush current occurred, distinguish sympathetic inrush or not by using differential current of adjacent transformer. This algorithm have the advantage of the distinguishing initial inrush and sympathetic inrush at operation of parallel transformer

  • PDF

Design of the High Density Power Supply with Flat Transformer (Flat Transformer를 적용한 고밀도 전원장치 설계)

  • Baek J.W.;Kim J.H.;Yoo D.W.;Kim J.S.;Ryu M.H.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.248-256
    • /
    • 2005
  • This paper presents the design method of the DC/DC converter using flat transformer which is suitable for midium or large capacity and high density power supply. Flat transformer module is composed and manufactured of multi-transformers in parallel and has a number of parallel single turn secondary windings. Therefore, its leakage inductance is highly decreased and it is more suitable for high frequency operation than conventional one. In this paper, we manufactured and tested 750W AC/DC converter with variable output powers to verify the performance of the flat transformer.

10kVA high $T_c$ Superconducting Power Transformer with Double Pancake Windings (더블팬케이크 권선형 10kVA 고온초전도 변압기)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Han, Song-Yeop;Ryu, Gyeong-U;Choe, Gyeong-Dang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.65-72
    • /
    • 2001
  • This paper presents the design and test results of a 10kVA single phase HTS transformer which is operating at 77K. Double pancake windings with BSCCO -2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Four double pan cake windings were used in pancake windings are connected in parallel to conduct the secondary current of 45.4A. the rated voltages of each winding are 440/220V. Numerical calculation using Finite Element Method was used to evaluated the performance of each arrangement. Considering the magnetizing reactance, leakage reactance, electrical insulation and the circulating current in low voltage winding which had two windings in parallel, HLLH arrangement was finally chosen. Estimation of the AC loss, magnetizing loss and self field loss, in the design stage, where effects of perpendicular field and parallel field are considered. Room temperature bore type cryostat has been constructed and its heat loss was measured.

  • PDF

A fault current analysis and parallel FCL scheme on superconducting new power system (초전도(신)전력계통 고장전류 분석 및 병렬한류시스템)

  • Yoon, Jae-Young;Lee, Seung-Ryul;Kim, Jong-Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.49-53
    • /
    • 2006
  • This paper specifies the new power supply paradigm converting 154kV voltage level into 22.9kV class with equivalent capacity using superconducting rower facilities and analyze the fault current characteristics with and without HTS-FCL (High Temperature Superconducting-Fault Current Limiter). Superconducting new power system is the power system to which applies the 22.9kV HTS cable in parallel to HTS transformer and HTS-FCL with low-voltage and mass-capacity characteristics replacing 154kV conventional cable and transformer. The fault current of superconducting new power system will increase greatly because of the mass capacity and low impedance of HTS transformer and cable. This means that the HTS-FCL is necessary to reduce the fault current below the breaking current of circuit breaker. This paper analyze the fault current and suggests the parallel HTS-FCL scheme complementing the inherent problem of HTS-FCL, that is recovery after quenching is impossible within shorter than a few seconds.

A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer (압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구)

  • 변재영;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.504-511
    • /
    • 2003
  • In this paper, inverter type neon power supply using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed neon power supply is composed of basic circuit and blocks, such as rectifier part, frequency oscillation part and piezoelectric transformer and resonant half bridge inverters. In this paper for complement the low power limitation, piezoelectric transformer at parallel connected driving by inverter is studied for noon tubes system of high power. When piezoelectric transformer is connected with parallel, LC filter connection method with parallel and selection of inductance L and capacitor C of primary side is suggested for reduce unbalanced current at the terminal of each transformer. Piezoelectric transformers use piezoelectric ceramic devices. Thus it is wireless therefore it has high power density, high Isolation level, low loss, more light, and miniaturization. In addition, high voltage transfer ratio is expected because there is no leakage inductance. Also, it has economic merit that the electrical loss Is low because structure is simple, small and tighter weight.

The Parallel Operation of ZVT-Full Bridge Converter with Dynamic Current Shared Inductor (동적 전류분담 인덕터를 이용한 ZVT 풀 브리지 컨버터의 병렬 운전)

  • Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.15-21
    • /
    • 2002
  • This paper presents parallel operation of ZVT(Zero Voltage Transition) FUll Bridge Converter with Dynamic Current Shared Inductor. In the conventional method, CT(Current Transformer) have been used tn share the load current equally with converters. In this system, at parallel operation of ZVT Full Bridge Converter, dynamic current shared inductor divides the same current of unit converter and ZVT circuit aids to high efficiency. Superiority of the characteristics is verified through the experiment with a 2[㎾], 50[㎑] prototype converter.

Coreless PCB transformer in HB ZVS DC/DC converter for vehicle FPL lamp power circuit (Coreless PCB 변압기를 이용한 자동차 전원 구동 FPL 램프 전원 회로)

  • Lee Wan-Yun;Chung Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.253-256
    • /
    • 2002
  • This paper proposes the application of coreless PCB transformer to Half-Bridge (HB), Zero-voltage-Switched (ZVS) DC/DC converter for FPL lamp with electronic ballast in vehicle. The designed 5 coreless PCB transformers for ballast driving voltage are parallel-connected in primary windings and series-connected in secondary windings. Coreless PCB transformer is designed to have spiral winding in order to transfer higher energy. The computer simulations of the proposed power circuit show coreless PCB transformer to have good performance.

  • PDF

Design of a 1 MVA HTS Transformer with Double Pancake Windings

  • Kim, Woo-Seok;Park, Kyeong-Dal;Joo, Hyeong-Gil;Han, Jin-Ho;Hong, Gye-Won;Park, Jungho;Heesuck Song;Kim, Sung-Hoon;Hahn, Song-yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.48-51
    • /
    • 2003
  • A 1 MVA transformer with BSCCO-2223 high Tc superconducting (HTS) tapes was designed. The rated voltages of each sides of the transformer are 22.0 kV and 6.6 kV respectively. Double pancake HTS windings, which have advantages of insulations and distribution of high voltage, were adopted. Four HTS tapes were wound in parallel fer the windings of low voltage side. Each winding was composed of several double pancake windings made of four parallel conductors were transposed in order to distribute the currents equally in each conductor. A core of the transformer was designed as a shell type core made of laminated silicon steel plate and the core is separated with the windings by a cryostat with a room temperature bore. The operating temperature of HTS windings will be 65K with liquid nitrogen, and a cooling system using a cryocooler was proposed and designed conceptually. This HTS transformer is going to be manufactured in near future based on the design parameters presented in this paper.

An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer (낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.

Design of a IMVA Single-Phase HTS Power Transformer

  • Kim, Sung-Hoon;Kim, Woo-Seok;Park, Chan-Bae;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.86-89
    • /
    • 2002
  • In this paper, the design of a IMVA single-phase high temperature superconducting(HTS) power transformer with BSCCO-2223 HTS tapes is presented. The rated voltages of each sides of the transformer are 22.9 ㎸ and 6.6 ㎸, respectively The winding of 1MVA HTS transformer is consisted of double pancake type HTS windings, which have advantages of insulation and distribution of high voltage, and are cooled by subcooled liquid nitrogen of 65K. Four HTS tapes were wound in parallel for the windings of low voltage side and the four parallel conductors are transposed. The design of 1MVA HTS transformer, a shell type core made of laminated silicon steel plate is chosen, and the core is separated with the windings by a cryostat with a room temperature bore. The cryostat made of non-magnetic and non-conducting material and a liquid nitrogen sub-cooling system is designed in order to maintain the coolant's temperature of 65K. For electromagnetic analysis of 1MVA HTS transformer, a finite element method of an axis of symmetry is used. The maximum perpendicular component of magnetic flux density of pancake windings is about 0.15T. And through analyzing the magnetic field distribution, an optimal winding arrangement of 1MVA HTS transformer is obtained.

  • PDF