• 제목/요약/키워드: Parallel transformer

검색결과 224건 처리시간 0.026초

액체질소 중에서의 연면방전 특성 (Characteristics of Surface flashover in LN2)

  • 정종만;백승명;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2003
  • For the development of superconducting power apparatus, it is necessary to establish the dielectric technology in coolant like L$N_2$. Therefore in this paper we conducted experiment of surface flashover that could occur in the windings of HTS transformer which will be developed in the pancake coil type. First, we distinguished two types of surface flashover by electrode alignment, such as parallel and vertical, and then compared with each characteristics of surface flashover. The flashover voltage was more affected by thickness of spacer than by surface length when the thickness of spacer is over 1 mm. And the surface flashover with metallic particle attached on the spacer was tested, it was affected by the particle position. The more close to the electrodes, the worse the characteristics. Also the experiment was conducted when the electrode was immersed in liquid nitrogen(L$N_2$) partially. The surface flashover characteristics of spacer was, when immersed partially in 50%, rapidly decreased.

LED 조명용 구동장치에서 열간 전류의 불평형 감소방법 (The Reduction Method of Strings Current Unbalancing in LED Lighting Driving System)

  • 박종연;송재욱;유진완
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.26-32
    • /
    • 2013
  • The LED has the proportional characteristic between the flux of light and its current and has caused voltage-current deviation on production process. Thus the unbalancing of each LED strings current occurred by its characteristic deviation. This unbalancing reduce a uniformity of the flux of light. Therefore, we researched to design method the LED driver based on DSP and the balancing transformer for a LED current balancing. These are applied to 50W LED module consist of 4 parallel strings. We analyzed the reduction of LED currents unbalance by experimental result from each method.

345[kV] 전력용 변압기 %임피던스 변화에 따른 계통영향 분석 (A Study on the Impact of the Impedance Change of 345[kV] Power Transformers on Overall System Performance)

  • 신정훈;남수철;이재걸;백승묵;송지영;김태균
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.140-149
    • /
    • 2011
  • This paper deals with the impact analysis of the impedance change of 345/154[kV] power transformers on the KEPCO system's overall performance. Through the steady-state and dynamic analysis of power system, the maximum available impedance of power transformers were determined. Checking violation of short-circuit current ratings and transformer overload, parallel operation of power transformers, calculation of voltage variation ratio according to the impedance changes of power transformers are included in the steady-state analysis. In addition, transient and voltage stability analysis are also performed in the study. Available magnitudes to be able to change the impedance of the transformers in KEPCO system are finally determined in the paper.

낮은 커플링 변압기를 갖는 개선된 고효율 공진 컨버터 (An improved high efficiency resonant converter with low coupling transformer)

  • 공영수;김은수;양승철;박진영;김종무;강도현;조정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1166-1168
    • /
    • 2004
  • The high frequency series resonant converter has been widely used for the non-contact power supply system with the large air gap and the increased leakage inductance of the non-contact transformer. However. the high frequency series resonant converter has the disadvantages of high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, unit voltage gain is revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation results and the 5kW experimental prototype.

  • PDF

A Study of a Simple PDP Driver Architecture using the Transformer Network

  • Kim, Woo-Sup;Shin, Jong-Won;Chae, Su-Yong;Hyun, Byung-Chul;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.148-155
    • /
    • 2008
  • In this paper, a cost-effective PDP driving circuit using the transformer network is proposed. Compared with the previous works, the half-bridge type energy recovery circuit recovers the reactive energy not to the capacitor but to the source. A single sustain board architecture removes the blocking switches which are placed on the discharge path in parallel, thus reducing the number of devices. A simple reset circuit generates the same waveforms as the previous approaches. The circuit configuration and modified driving waveforms are compared with the previous works. The validity of the proposed simplified driver is verified through tests using a 6-inch panel.

무접점 전력용 변환기의 다중공진형 토폴로지 비교 (Comparison of Higher-Order Resonant Topologies for Contact-less Power Converter Systems)

  • 다니엘;박종후
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.323-324
    • /
    • 2014
  • A higher-order power converter topology for an extremely low coupling (less than 0.15) transformer with high efficiency and wide air-gap (23 mm) is presented in this paper. Among the typical resonant converter topologies for contact-less power transferring systems, Series-Series Resonant Converter (SSRC) and Series-Parallel Resonant Converter (SPRC) are widely used in number of power electronic applications. However, when coupling coefficient of a transformer is seriously low (k<0.5), the series-series resonant converter will possibly operate at short circuited condition because of the small magnetizing impedance. To solve this problem, a modified and improved topology of seventh-order resonant converter for contact-less power converter system is proposed and the results are presented.

  • PDF

PRACTICAL EVALUATIONS OF PARASITIC RESONANT PWM DC-DC CONVERTERS FOR HIGH-POWER MEDICAL USE

  • H. Takano;J. Takahashi;Sun, J.M.;L... Gamage;M. Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.701-708
    • /
    • 1998
  • This paper presents a novel non-resonant PWM DC-DC converter for X-ray high-voltage power generator using the parasitic impedances of the high-voltage high-frequency link transformer with its output high-voltage control scheme and steady-state characteristics compared to the conventional series-parallel resonant DC-DC converter. The key point of this approach is to evaluate effectiveness of reduction of the turn ratio of the high-voltage high-frequency transformer on improvements in power conversion efficiency and the power factor applying a boost AC-DC converter as DC voltage source, especially in the long exposure term and light output load ranges.

  • PDF

단상 GTO PWM CONVERTER의 병렬운전 (Parallel Operation of Single-Phase GTO PWM Converters)

  • 이현동;이동춘;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.415-418
    • /
    • 1994
  • In this paper, a parallel operation of two single-phase GTO PWM converters is presented. The current ripples on the primary side of the transformer can be much reduced by shifting one modulation period from the other one by a half period. Also, a simple power factor control scheme is presented by which the reactive component of converter input current is controlled. Simulations and experimental results for a laboratory system confirm the validity of the purposed algorithm.

  • PDF

Individual Charge Equalization Converter with Parallel Primary Winding of Transformer for Series Connected Lithium-Ion Battery Strings in an HEV

  • Kim, Chol-Ho;Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-Hui
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.472-480
    • /
    • 2009
  • In this paper, a charge equalization converter with parallel-connected primary windings of transformers is proposed. The proposed work effectively balances the voltage among Lithium-Ion battery cells despite each battery cell has low voltage gap compared with its state of charge (SOC). The principle of the proposed work is that the equalizing energy from all battery strings moves to the lowest voltage battery through the isolated dc/dc converter controlled by the corresponding solid state relay switch. For this research a prototype of four Lithium-Ion battery cells is optimally designed and implemented, and experimental results show that the proposed method has excellent cell balancing performance.

Coupled Inductor-Based Parallel Operation of a qZ-Source Full-Bridge DC-DC Converter

  • Lee, Hyeongmin;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2015
  • This study presents a novel transformer isolated parallel connected quasi Z-source (qZ-source) full-bridge DC-DC converter that uses a coupled inductor in both the qZ-source network and output filter inductor. Unlike traditional voltage-fed or current-fed converters, the proposed converter can be open- and short-circuited without damaging switching devices. Therefore, the desired buck and boost functions can be achieved and converter reliability can be significantly improved. All the bulky inductors in the qZ-source network and output filter can also be minimized with the proposed inductor structures. A 4 kW prototype DC-DC converter is built and tested to verify the performance of the proposed converter.