• Title/Summary/Keyword: Parallel load control

Search Result 287, Processing Time 0.027 seconds

A Study of Two Phase Chopper System with Four Separate Groups of DC Motors in Powering (타동용 4 분제 2상쵸퍼방식의 특성)

  • 정연택;한경희;김용주;이영일;오봉환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.171-178
    • /
    • 1987
  • A study of two phase chopper system with four separate groups of DC motors in powering. A novel two phase chopper system with four separate groups of DC motors which applies the principles of two phase chopper with two separate groups of DC motors is dealt with this article. The main circuit consists of eight sets of chopping parts, four diodes and four separate groups of DC motors. Four groups of DC motors are driven through the series and parallel connections to each other in accordance with the operating conditions of the choppers. Although the proposed chopper circuit requires more circuit elements than the conventional two phase chopper system with combined output or two phase chopper system with two separate groups of DC motors, it has the following advantages` (1). It is possible to drive twice as much motors as conventional system does, using esisting receiving-and equipments and motors. (2). It is possible to control load voltage continuously from 0 to source voltage by changing time-ratio from 0 to 1. (3). Load current division becomes equalized. Therefore it is possible to drive not only series motors but also shunt and separately exited motors. (4). When smoothing reactor L is small, harmonic components of the proposed circuit is not so large. Therefore, the value of L can be determined from viewpoints of allowable value of ripple-ratio and current unbalance factor.

Instantaneous Reactive Power Compensator using Current Controlled PWM Converter (전류제어형 PWM 컨버터에 의한 순시 무효전력 보상장치)

  • 최재호;김상훈;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.539-548
    • /
    • 1989
  • This paper describes an instantaneous reactive power compensator aimed at the compensation of reactive power and current harmonics of a thyristor load. A new definition of the instantaneous reactive power consisting of both displacement of fundamental current and harmonic distortion current is proposed and the physical meaning is investigated from the viewpoint of an instantaneous power flow. The instantaneous reactive power is calculated from the feedback of instantaneous voltage, current and is compensated by the current controlled PWM converter connected in parallel with the load. The PWM converter operates as a high performance current control scheme, because adopts the excellent current controlled PWM technique based on the current deviation vector. Both simulation and experimental results show good compensating performances in steady and transient state.

Thermal-structural Analysis and Fatigue Life Evaluation of a Parallel Slide Gate Valve in Accordance with ASME B&PVC (패러럴 슬라이드 게이트밸브의 열구조해석 및 ASME B&PVC 기반 피로수명 평가)

  • Kim, Tae Ho;Choi, Jae Seung;Han, Jeong Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.157-164
    • /
    • 2017
  • A parallel slide gate valve (PSGV) is located between the heat recovery steam generator (HRSG) and the steam turbine in a combined cycle power plant (CCPP). It is used to control the flow of steam and runs with repetitive operations such as startups, load changes, and shutdowns during its operation period. Therefore, it is necessary to evaluate the fatigue damage and the structural integrity under a large compressive thermal stress due to the temperature difference through the valve wall thickness during the startup operations. In this paper, the thermal-structural analysis and the fatigue life evaluation of a 16-inch PSGV, which is installed on the HP steam line, is performed according to the fatigue life assessment method described in the ASME B&PVC VIII-2; the method uses the equivalent stress from the elastic stress analysis.

Fuzzy-based Processor Allocation Strategy for Multiprogrammed Shared-Memory Multiprocessors (다중프로그래밍 공유메모리 다중프로세서 시스템을 위한 퍼지 기반 프로세서 할당 기법)

  • 김진일;이상구
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.5
    • /
    • pp.409-416
    • /
    • 2000
  • In the shared-memory mutiprocessor systems, shared processing techniques such as time-sharing, space¬sharing, and gang-scheduling are used to improve the overall system utilization for the parallel operations. Recently, LLPC(Loop-Level Process Control) allocation technique was proposed. It dynamically adjusts the needed number of processors for the execution of the parallel code portions based on the current system load in the given job. This method allocates as many available processors as possible, and does not save any processors for the parallel sections of other later-arriving applications. To solve this problem, in this paper, we propose a new processor allocation technique called FPA(Fuzzy Processor Allocation) that dynamically adjusts the number of processors by fuzzifYing the amounts ofueeded number of processors, loads, and estimated execution times of job. The proposed method provides the maximum possibility of the parallism of each job without system overload. We compare the performances of our approaches with the conventional results. The experiments show that the proposed method provides a better performance.

  • PDF

A Quasi Z-Source AC-AC Converter with a Low DC Voltage Distribution Capability Operating as a Power Electronic Transformer (전력전자 변압기로 동작하는 저전압 직류배전 기능을 갖는 Quasi Z-소스 AC-AC 컨버터)

  • Yoo, Dae-Hyun;Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.358-366
    • /
    • 2014
  • This paper proposes a quasi Z-source AC-AC converter with the low DC voltage distribution capability operating as a power electronic transformer. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel, also their output terminal are connected in series. Simple control method of duty ratio was proposed for the in phase buck-boost AC voltage mode and the DC output voltage control. DSP based experiment and PSIM simulation were performed. As a result, the PSIM simulation results were same with the measured results. By controlling the duty ratio under the condition of 100 [${\Omega}$] load, quasi Z-source AC-AC converter could buck and boost the AC output voltage in phase with the AC input voltage, and the same time, the constant DC voltage could be output without affecting the AC output characteristics. And, the DC output voltage 48[V] was constantly controlled in dynamic state in case while the load is suddenly changed ($50[\Omega]{\rightarrow}100[\Omega]$). From the above result, we could know that the quasi Z-source AC-AC converter can act as a power electronic transformer with a low DC voltage distribution capability.

Technology Development for Stabilization of PV Independent System (태양광발전시스템 독립계통 안정화 기술개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.181-186
    • /
    • 2019
  • In order to reduce the fossil fuels consumed in conventional commercial independent diesel generators in the same environment as the island area, it is necessary to develop a photovoltaic system that will bear more than 40% of the independent system capacity. For this development, it is necessary to develop a high-capacity inverter that can improve the stability of the independent system installed in the island area and supply high-quality power to the load. In addition, the EMS power generation control system for the independent grid photovoltaic power generation system is a parallel operation power control system of the diesel generator connected with the solar power generation system. It controls the output of the diesel generator according to the load ratio and the solar power generation, A stable supply system is needed. This independent grid photovoltaic generation system can increase the solar power supply to the independent system area and increase the power stability of the independent system and further reduce the use of fossil fuel due to the ineffective power control of the independent system. It is expected that the economy will be secured early.

A Comparative Study on the Bus Voltage Control Effect of STATCOM and UPFC in Power Flow Analysis of Power Systems (전력계통의 조류해석에서 STATCOM과 UPFC의 모선전압 제어효과에 대한 비교연구)

  • 김덕영;국경수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an comparative study on the effect of STATCOM and UPFC to power flow analysis of power systems. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for power flow analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

Auto Regulated Data Provisioning Scheme with Adaptive Buffer Resilience Control on Federated Clouds

  • Kim, Byungsang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5271-5289
    • /
    • 2016
  • On large-scale data analysis platforms deployed on cloud infrastructures over the Internet, the instability of the data transfer time and the dynamics of the processing rate require a more sophisticated data distribution scheme which maximizes parallel efficiency by achieving the balanced load among participated computing elements and by eliminating the idle time of each computing element. In particular, under the constraints that have the real-time and limited data buffer (in-memory storage) are given, it needs more controllable mechanism to prevent both the overflow and the underflow of the finite buffer. In this paper, we propose an auto regulated data provisioning model based on receiver-driven data pull model. On this model, we provide a synchronized data replenishment mechanism that implicitly avoids the data buffer overflow as well as explicitly regulates the data buffer underflow by adequately adjusting the buffer resilience. To estimate the optimal size of buffer resilience, we exploits an adaptive buffer resilience control scheme that minimizes both data buffer space and idle time of the processing elements based on directly measured sample path analysis. The simulation results show that the proposed scheme provides allowable approximation compared to the numerical results. Also, it is suitably efficient to apply for such a dynamic environment that cannot postulate the stochastic characteristic for the data transfer time, the data processing rate, or even an environment where the fluctuation of the both is presented.

A Comparative Study on the Effect of SSSC and UPFC in Static Analysis of Power Systems (전력계통의 정태해석에 미치는 SSSC와 UPFC의 영향에 대한 비교 연구)

  • Kim, Deok-Young;Cho, Eon-Jung;Lee, Kun-Jae;Lee, Ji-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.155-157
    • /
    • 2001
  • This paper presents an comparative study on the effect of SSSC and UPFC to the power system static analysis. SSSC is used to control active power flow in transmission lines by controlling the phase angle of the injected voltage source which is in rectangular to the line current. UPFC is used to control the magnitude and phase of the injected voltage sources which are connected both in series and in parallel with the transmission line to control power flow and bus voltage. To compare the effect of SSSC and UPFC in power system static analysis, the PSS/E simulation program is used. As the FACTS device model such as SSSC and UPFC is not provided in PSS/E yet, an equivalent load model is used. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to improve bus voltage than SSSC in power system static analysis.

  • PDF

Experimental Study on the Characteristics of Misaligned Self-equalizing Tilting Pad Thrust Bearing (자려 평형 틸팅 패드 스러스트 베어링의 정렬불량에 따른 베어링 특성에 관한 실험적 연구)

  • Song, AeHee;Jo, HyunJun;Choi, SeongPil;Kim, SeonJin
    • Tribology and Lubricants
    • /
    • v.36 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Self-equalizing tilting pad thrust bearings are usually employed in turbomachines to achieve high stability and reliability. A tilting pad bearing can incorporate self-equalizing links to handle the misalignment between the bearing and the thrust collar. In this popular design method, the pads sit on the upper-level plates and the lower-level plates stay on the retainer base. With misalignment, the pads that are heavily loaded are pushed down. Consequently, the link pushes up the pads on the opposite side, keeping the bearing surface parallel to the thrust collar surface. The self-equalizing link is used to handle the misalignment from the thermal and mechanical effects. In this study, the experimental investigation deals with the performance of self-equalizing tilting pad thrust bearings. The test rig for evaluating the performance of bearing is developed which can control the misalignment angle. Simultaneous measurements are taken for the force acting on each pad. Pad metal temperature and oil film thickness are functions of the shaft speed, bearing load, misalignment angle, and design of leveling plates. The effect of misalignment on bearing performance is discussed. The results demonstrate that the load on each pad depends on the test conditions(especially misalignment angle), and the load influences the performance of bearings.