• 제목/요약/키워드: Parallel link

검색결과 249건 처리시간 0.041초

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

1.5Gbps 직렬 에이티에이 전송 칩 구현 (Implementation of 1.5Gbps Serial ATA)

  • 박상봉;허정화;신영호;홍성혁;박노경
    • 대한전자공학회논문지SD
    • /
    • 제41권7호
    • /
    • pp.63-70
    • /
    • 2004
  • 본 논문에서는 PC 의 스토리지 인터페이스로 사용되는 병렬 ATA를 대체하게 될 새로운 표준인 직렬 ATA 의 링크 층과 물리 층을 설계하였다. 링크층에서는 CRC 생성 및 오류 감지, 스크램블링 회로, 8b/10b 복호화/부호화 회로 및 프리미티브 생성/검파 회로로 구성되었다. 물리 층은 직렬화/병렬화 회로와 전원 초기 인가시의 리셋 발생회로, OOB 신호 발생/검파 회로, 데이터로부터 클록을 복원하는 회로, 스?치 회로 및 임피이던스 조정 회로와 콤마 발생/감지 회로로 설계하였나. 또한 불리 층과 링크층의 동작을 확인하기 위한 테스트 제어 블록과 BIST(Built In Self Test) 블록을 설계하였다. UMC 사의 0.18㎛ 표준 CMOS 공정을 이용하여, 칩으로 제작 후 특성을 검증하였다. 링크 층에서 요구하는 모든 기능 및 특성은 사양을 만족하였고, 물리 층의 출력 전압 및 드라이버 출력 지터, OOB 신호등의 특성도 만족하였다. 데이터 전송 율은 1.5Gbps 속도의 사양목표치에 비해서, 실제 측정된 데이터 전송 속도는 1.28Gbps로 측정되었다. 회로 시뮬레이션에 의한 확인 결과, 레이아웃에서의 배선에 대한 기생 성분의 영향에 의한 것으로 분석되었다.

에너지 저장장치를 갖는 고 전력밀도 및 저가격형 태양광 인버터 시스템 (High Power Density and Low Cost Photovoltaic Power Conditioning System with Energy Storage System)

  • 금문환;장두희;홍성수;한상규;사공석진
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.587-593
    • /
    • 2011
  • 본 논문에서는 고 전력밀도 및 저가형으로 구성 가능한 새로운 구조의 계통 연계형 태양광 인버터 시스템을 제안한다. 제안 시스템은 태양전지의 최대 전력점 추종기능과 배터리의 충 방전 기능을 단일 전력단으로 구성함으로써, 고 전력밀도 및 저가격형 시스템 구성이 가능하다. 또한, 제안 시스템은 배터리를 링크 캐패시터에 직렬 연결함으로써 링크 캐패시터의 전압 스트레스를 배터리 전압만큼 저감할 수 있으므로 가격저감 효과가 크다. 최종적으로 제안 시스템의 우수성과 신뢰성 검증을 위하여 1.5kW급 태양광 인버터 시스템의 시작품을 제작하였고, 이를 이용한 실험결과를 바탕으로 제안 시스템의 타당성을 검증한다.

통신부담을 감소시킨 영상처리를 위한 병렬처리 방식 ASIC구조 설계 (Design of an Image Processing ASIC Architecture using Parallel Approach with Zero or Little)

  • 안병덕;정지원;선우명훈
    • 한국통신학회논문지
    • /
    • 제19권10호
    • /
    • pp.2043-2052
    • /
    • 1994
  • 본 논문에서는 근접한 Processing Element(PE)들간의 통신 부담을 경감시켜 영상신호를 실시간 처리할 수 있는 새로운 병렬처리 방식 ASIC 구조를 설계한다. 하나의 Sliding Memory Plane (SliM) Image Processor chip을 병렬처리 방식을 사용 $3\times3$ PE를 격자 형태로 연결한다. 제안하는 Image Processor를 구현할 수 있다. Sliding 개념은 별도의 보조 프로세서나 DMA를 사용치 않고 또한 PE들을 interupt 걸지 않고 모든 화소가 이웃 PE로 이동됨을 의미한다. 따라서 근접 통신과 계산이 동시에 일어나 기존의 격자 연결 병렬 컴퓨터의 결정적 단점인 근접 통신 부담을 경감시킬 수 있다. 또한 하나의 PE에 두 개의 입출력용 레지스터 plane을 사용, buffer를 제공하여 입출력 부담을 감소시킨다. SliM Image Processor에서는 단지 4개의 통신 link만으로 8가지 방향의 통신경로를 제공하는 by-passing path에 의해 통신 부담없이 대각선 통신을 수행할 수 있다. 제안하는 유일한 특성들로 인해 영상 신호 처리시 성능을 향상시킬 수 있다. 영상신호 처리를 위한 알고리즘들을 효율적으로 수행키 위한 PE, Image Processor 구조 및 명령어를 설계한다.

  • PDF

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF

웨이브릿 기반 비디오 신호의 멀티 스트림 전송 기법 (Multi-stream Delivery Method of the Video Signal based on Wavelet)

  • 강경원;류권열;권기룡;문광석;김문수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(3)
    • /
    • pp.101-104
    • /
    • 2001
  • Over the last few years, streaming audio and video content on Internet sites has increased at unprecedented rates. The predominant method of delivering video over the current Internet is video streaming such as SureStream or Intelligent Stream. Since each method provides the client with only one data stream from one server, it often suffers from poor qualify of pictures in the case of network link congestion. In this paper, we propose a novel method of delivering video stream based on wavelet to a client by utilizing multi-threaded parallel connections from the client to multiple servers and to provides a better way to address the scalability functionalities. The experimental results show that the video quality delivered by the proposed multithreaded stream could significantly be improved over the conventional single video stream methods.

  • PDF

다중 프로세서를 갖는 SoC 를 위한 CDMA 기술에 기반한 통신망 설계 (A CDMA-Based Communication Network for a Multiprocessor SoC)

  • 천익재;김보관
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.707-710
    • /
    • 2005
  • In this paper, we propose a new communication network for on-chip communication. The network is based on a direct sequence code division multiple access (DS-CDMA) technique. The new communication network is suitable for a parallel processing system and also drastically reduces the I/O pin count. Our network architecture is mainly divided into a CDMA-based network interface (CNI), a communication channel, a synchronizer. The network includes a reverse communication channel for reducing latency. The network decouples computation task from communication task by the CNI. An extreme truncation is considered to simplify the communication link. For the scalability of the network, we use a PN-code reuse method and a hierarchical structure. The network elements have a modular architecture. The communication network is done using fully synthesizable Verilog HDL to enhance the portability between process technologies.

  • PDF

인터리빙 방식을 이용한 3병렬 풍력 발전 시스템의 직류단 전류 리플 저감 기법 (DC-Link Current Ripple Reduction with an Interleaving Scheme in Three-Parallel Wind Power System)

  • 정민교;아나톨리;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.249-250
    • /
    • 2016
  • 본 논문에서는 3병렬 풍력발전 시스템의 직류단 전류 리플을 저감하기 위한 인터리빙 기법을 제안한다. 병렬 구조의 풍력발전 시스템은 각 발전기 측 컨버터의 전류 고조파로 인해 직류단에 전류 리플이 발생한다. 이러한 전류 고조파들의 합과 관련된 전류 리플은 직류단 커패시터의 수명 단축 및 전체 시스템의 손실을 유발한다. 이를 방지하기 위해 3병렬 풍력발전 시스템에서의 전류 고조파를 분석하고, 전류 리플을 최소화하기 위한 최적의 인터리빙 각을 구하여 전류 리플을 저감하는 기법을 제안한다. 제안하는 기법의 타당성을 PSIM 시뮬레이션을 통해 확인한다.

  • PDF

중대형 리튬폴리머 2차전지용 충방전기 개발 (Design of a cycler system for large capacity lithium-polymer battery)

  • 오동섭;오성업;이종윤;박민호;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.82-86
    • /
    • 2004
  • In this paper, a cycler system for the Lithium-Polymer battery with the large capacity of 120Ah is presented. This system is constituted as the two units for the charging and discharging. The Lithium-Polymer battery should be charged in CC and CV mode, and it is required a very high precision control of the voltage and current for the charging unit. To decrease the switching noises and harmonics, parallel operation method is adopted and utilized in the power conversion module. The discharging unit has a link AC system function to return the discharging energy of battery to AC line and has comparatively less thermal loss. These units are designed to be controlled and monitored by personal computer. The total system for the battery charging and discharging is described and presented.

  • PDF

고온 초전도 자속흐름 트랜지스터에 적용된 전자냉각 특성 시뮬레이션 (Characteristics Simulation of Electronics Cooling for a High-Temperature Superconducting Flux Flow Transistor Circuit)

  • 고석철;강형곤;임성훈;두호익;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1063-1066
    • /
    • 2002
  • An equivalent circuit for the superconductor flux flow transistor(SFFT) was combined with high temperature cooling device, based on the analogy between thermal and electrical variables using the high-temperature superconductor(HTS), is proposed. The device is composed of parallel weak links with a nearby magnetic control line. A model has been developed that is based on solving the equation of motion of Abrikosov vortices subject to Lorentz viscous and pinning forces as well as magnetic surface barriers. The use of thermal models the global performance of thermal cooling circuit and signal system to be checked by using electrical circuit analysis programs such as SPICE.

  • PDF