• Title/Summary/Keyword: Parallel lines

검색결과 399건 처리시간 0.044초

平활材表面 의 微小피勞균열에 관한 基礎的 特性 (Basic Characteristics of Micro-Fatigue-Cracks on the Unnotched Smooth Specimens)

  • 서창민;북천영부;결성양치
    • 대한기계학회논문집
    • /
    • 제7권1호
    • /
    • pp.28-35
    • /
    • 1983
  • Quantitative analysis have been carried out on the micro-cracks on the surface and into the depth of unnotched smooth mild steel specimen under cyclic stains by rotating bending fatigue tests. Some of the results are; (1) Cracks initiate at the early stage of fatigue life N$_{I}$/ N$_{f}$=10 to 20%, and propagate during the rest of fatigue life. (2) Coalescence of highly crowded small fatigue cracks of random distribution seems to induce the final fracture at higher stress level. (3) The curves of crack initiation and the equal crack length on the graph of stress versus number of cycles are parallel to the S-N curve. (3) The curves of crack initiation and the equal crack length on the graph of stress versus number of cycles are parallel to the S-N curve. (4) The distributions of micro-surface crack length and depth show the composite Weibull distributions which are approximated to two straight lines separated by the value of transient region between stage I and stage II crack.k.k.

초고압 송전선로에서 가스관에 미치는 유도 장해 해석 (Analysis of Inductive Interference from EHV Transmission to buried Gas Pipelines)

  • 이승연;고은영;윤석무;박남옥;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.458-460
    • /
    • 2000
  • In this paper, we analyze the inductive coupling between overhead power transmission lines and neighbouring gas pipelines or other conductors, when they parallel to a line section in a phase-to-earth fault is assumed on the transmission line. A numerical procedure employing the finite-element method(FEM) is used in conjunction with Faraday's law, in order to predict the current in a faulted transmission line as well as the induced voltages across points on a pipeline running parallel to the faulted line and remote earth. The results lead to conclusion that may be useful to power system engineers.

  • PDF

평형 2회선 송전 계통의 1선지락시 고장점 표정 알고리즘 (Parallel Transmission Lines Fault location Algorithm for single line-to-ground fault)

  • 양하;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.317-319
    • /
    • 2006
  • This paper proposes a fault location algorithm for two-parallel transmission line in the case of single line-to-ground fault Proposed algorithm is using voltage and current measured in the sending-end. The fault distance is simply determined by solving a second order polynomial equation due to the direct circuit analysis. The simulations by PSCAD/EMTDC have demonstrated the accuracy and effectiveness of the proposed algorithm.

  • PDF

565 Mb/s 광진속 시스템을 위한 병렬 검출방식을 이용한 프레임 동기 시스템 (A Frame Synchronization System Using a Parallel Detection Method for the 565 Mb/s Optical Transmission System)

  • 신동관;고정훈;이만섭;심창섭
    • 대한전자공학회논문지
    • /
    • 제25권8호
    • /
    • pp.859-866
    • /
    • 1988
  • A high speed frame synchronization system has been realized which generates the frame sync clock from 565Mb/s data stream (the DS-5 digital multiplex hierarchy signal). The design of a frame pattern detector using a parallel detection method brings into low speed operation and resolves the problems due to the high speed operation. The frame synchronization algorithm recommended by CCITT is also realized by designing a sync mode controller. Appropriate design procedures are considered for an efficient hardware design and minimized connection lines. The CAD simulation as well as experiment show that the performance of the newly designed frame synchronization system satisfies the relevant requirements.

  • PDF

병렬 처리 구조의 GPU를 이용한 의료 초음파 영상용 에코 신호 처리기 (An Echo Processor for Medical Ultrasound Imaging Using a GPU with Massively Parallel Processing Architecture)

  • 서신혁;손학렬;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.871-872
    • /
    • 2008
  • The method and results of the software implementation of a echo processor for medical ultrasound imaging using a GPU (NVIDIA G80) is presented. The echo signal processing functions are modified in a SIMD manner suitable for the GPU's massively parallel processing architecture so that the GPU's 128 ALUs are utilized nearly 100%. The preliminary result for a frame of image composed of 128 scan lines, each having 10240 16-bit samples, shows that the echo processor can be inplemented at a high rate of 30 frames per second when implemented in C, which is close to the optimized assembly codes running on the TI's TMS320C6416 DSP.

  • PDF

병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석 (Gas pulsation analysis of large reciprocating compressor in parallel operation)

  • 김성준;김현철;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.910-915
    • /
    • 2009
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

  • PDF

A Flexible and Tunable Microwave Photonic Filter Based on Adjustable Optical Frequency Comb Source

  • Tran, Thanh Tuan;Seo, Dongsun
    • 전기전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.27-32
    • /
    • 2015
  • A flexible and tunable microwave photonic filter based on adjustable optical frequency comb source is demonstrated. We use a combination of a dual parallel Mach Zehnder modulator and an intensity modulator to generate fifteen comb lines with proper weights to implement a desired filter. The optical comb weights, corresponding to the tap coefficients of the filter, are flexibly changed by adjusting the operation parameters of the modulators. The achieved bandwidth and stopband attenuation of the tunable filter are 0.7 GHz and 20 dB, respectively. In addition, we overcome the undesired low frequency suppression appeared in a conventional scheme by applying a dual parallel Mach Zehnder modulator for single sideband suppressed carrier modulation.

병렬 운전되는 대형 왕복동 압축기의 가스맥동 분석 (Gas Pulsation Analysis of Large Reciprocating Compressors in Parallel Operation)

  • 김성준;김현재;김현진
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.97-103
    • /
    • 2010
  • For large reciprocating compressors in parallel operation, an analytical study has been carried out on the gas pulsation in associated discharge piping lines. Since the pressure pulsation at a valve, valve dynamics, and the gas flow rate through the valve are interrelated, affecting one another, these need to be solved simultaneously. Acoustic transfer matrix method, which relates acoustic pressure and velocity at one location to those at another location, has been adopted to calculate the effect of the gas flow at one valve location on the gas pulsation at other valve locations.

Zero-one Integer Programming Approach to Determine the Minimum Break Point Set in Multi-loop and Parallel Networks

  • Moirangthem, Joymala;Dash, Subhransu Sekhar;Ramaswami, Ramas
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.151-156
    • /
    • 2012
  • The current study presents a zero-one integer programming approach to determine the minimum break point set for the coordination of directional relays. First, the network is reduced if there are any parallel lines or three-end nodes. Second, all the directed loops are enumerated to reduce the iteration. Finally, the problem is formulated as a set-covering problem, and the break point set is determined using the zero-one integer programming technique. Arbitrary starting relay locations and the arbitrary consideration of relay sequence to set and coordinate relays result in navigating the loops many times and futile attempts to achieve system-wide relay coordination. These algorithms are compared with the existing methods, and the results are presented. The problem is formulated as a setcovering problem solved by the zero-one integer programming approach using LINGO 12, an optimization modeling software.

직병렬아크사고 예방을 위한 마이컴 알고리즘 설계에 관한 연구 (A Study on Micom Algorithm Design for Prevention of Serial Parallel Arc Accident)

  • 최정규;곽동걸;최신형;정도영;김대환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.9-11
    • /
    • 2018
  • This paper studies on the development of an electric fire prevention system with the detection and alarm in case of parallel arc fault occurrence in low voltage distribution lines. The proposed detector has the characteristics of high speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. The line voltage is always feedback, and when an arc or a spark occurs, these are detected by the microcomputer. In addition, we design and develop algorithms using high speed and high precision microcomputer. A new conceptual control technique is adopted that RCD cuts-off by forming a forced short circuit between the phase voltage and ground in the event of an electrical accident. Some experimental tests of the proposed system also confirm practicality and the validity of the analytical results.

  • PDF