• Title/Summary/Keyword: Parallel Plate

검색결과 601건 처리시간 0.03초

Understanding of Non-Thermal Atmospheric Pressure Plasma Characteristics Produced in Parallel Plate Type Geometry

  • Choe, Wonho;Moon, Se Youn;Kim, Dan Bee;Jung, Heesoo;Rhee, Jun Kyu;Gweon, Bomi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.144-144
    • /
    • 2013
  • Non-thermal atmospheric pressure plasmas have recently garnered much attention due to their unique physical and chemical properties that are sometimes significantly different from those of low pressure plasmas. It can offer many possible application areas including nano and bio/medical areas. Many different types of plasma sources have been developed for specific needs, which can be one of the important merits of the atmospheric pressure plasmas since characteristics of the produced plasma depend significantly on operating parameters such as driving frequency, supply gas type, driving voltage waveform, gas flow rate, gas composition, geometrical factor etc. Among many source configurations, parallel plate type geometry is one of the simplest configurations so that it can offer many insights for understanding basic underlying physics. Traditionally, the parallel plate type set up has been studied actively for understanding low pressure plasma physics along with extensive employment in industries for the same reason. By considering that understanding basic physics, in conjunction with plasma-surface interactions especially for nano & bio materials, should be pursued in parallel with applications, we investigated atmospheric pressure discharge characteristics in a parallel plate type capacitive discharge source with two parallel copper electrodes of 60 mm in diameter and several millimeters in gap distance. In this presentation, some plasma characteristics by varying many operating variables such as inter-electrode distance, gas pressure, gas composition, driving frequency etc will be discussed. The results may be utilized for plasma control for widening application flexibility.

  • PDF

평행판 도파관을 이용한 유전율 측정 방법 (A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide)

  • 조규영;박위상
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.199-203
    • /
    • 2012
  • 평행판 도파관에 진행하는 TEM mode를 이용한 평판형 유전체의 유전율을 측정하는 방식을 소개한다. 이는 양 옆이 열린 구조적 장점으로 실험 절차 및 측정 샘플의 가공이 매우 간편한 장점이 있다. 샘플의 유무에 따라 변화하는 도파관 내에서 전파하는 TEM mode의 위상 속도의 차이를 전자기적으로 해석하였고 이를 이용하여 유전체판의 유전율을 측정하였으며, 샘플에 대한 측정 결과는 기존에 알려진 유전율과 일치하였다.

플랜지된 평행평판도파관으로 급전된 슬릿의 등가 어드미턴스 및 좁은 슬릿을 통한 최대결합 메커니즘 (Equivalent Admittance of a Slit Fed by a Flanged Parallel-Plate Waveguide and Maximum Coupling Mechanism through a Narrow Slit)

  • 이종익;김강욱;조영기
    • 한국전자파학회논문지
    • /
    • 제15권11호
    • /
    • pp.1116-1122
    • /
    • 2004
  • 플랜지된 평행 평판 도파관의 슬릿을 통한 전자기적인 결합문제를 고려하였다. 결합 슬릿 근처 도파관 내 $.$외부의 무효전력을 반영한 슬릿의 등가 어드미턴스를 구하고, 슬릿의 폭이 매우 좁은 경우에서의 최대결합 메커니즘을 규명하였다. 도파관의 높이, 슬릿의 폭 및 슬릿의 변위 등과 같은 구조적인 파라미터들이 복사 특성에 미치는 영향을 관찰하였다.

Wideband Suppression of Radiated Emissions from a Power Bus in High-Speed Printed Circuit Boards

  • Shim, Yujeong;Kim, Myunghoi
    • Journal of information and communication convergence engineering
    • /
    • 제14권3호
    • /
    • pp.184-190
    • /
    • 2016
  • We present experimental demonstrations of electromagnetic bandgap (EBG) structures for the wideband suppression of radiated emissions from a power bus in high-speed printed circuit boards (PCBs). In most of the PCB designs, a parallel plate waveguide (PPW) structure is employed for a power bus. This structure significantly produces the wideband-radiated emissions resulting from parallel plate modes. To suppress the parallel plate modes in the wideband frequency range, the power buses based on the electromagnetic bandgap structure with a defected ground structure (DGS) are presented. DGSs are applied to a metal plane that is connected to a rectangular EBG patch by using a via structure. The use of the DGS increases the characteristic impedance value of a unit cell, thereby substantially improving the suppression bandwidth of the radiated emissions. It is experimentally demonstrated that the DGS-EBG structure significantly mitigates the radiated emissions over the frequency range of 0.5 GHz to 2 GHz as compared to the PPW.

평행평판 장하에 의한 슬릿 침투 전자파의 저감 특성 (EDUCATION OF ELECTROMAGNETIC PENETRATION THROUGH NARROW SLOTS IN CONDUCTING SCREEN BY PARALLEL PLATE LOADING)

  • 박은정;주창현;김기채
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.66-68
    • /
    • 2005
  • This paper presents the reduction characteristics of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel plate connected on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. An integral equation for the aperture electric field on narrow slots is derived and solved by applying Galerkin's method of moments. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel plate on the slot aperture.

  • PDF

평행판 도파관내의 산란 도체에 의한 산란파 해석 (Analysis of scattering fields by conductors with arbitrary cross-section in parallel-plate waveguide)

  • 정봉식;김현정;김응수;조규완
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.65-73
    • /
    • 1995
  • In this paper, new algorithm which calculates transmission coefficient of electromagnetic wave by numerical analysis of scattered field by conductors with arbitrary cross-sections in parallel-plate waveguide is proposed. Proposed algorithm assumes magnetic current distribution on the boundary of scattering conductors, and applies Image theorem to perfect conductor surfaces of parallel-plate waveguide. Integral equations for fictitious magnetic currents on conducting boundary are set up. Magnetic current distributions on conducting boundary are expanded as exponential basis function, and using Galerkin method matrix equations are set wp. To compute matrix elements this method utilizes Fourier transform which is faster than numerical integration. Finally, frequency and incidence-angle characteristic of transmission coefficient are calculated and compared with experimental results.

  • PDF

평행 평판 정전형 구동기를 이용한 가변 광 감쇠기 (Variable Optical Attenuator using Parallel Plate Electrostatic Actuator)

  • 김태엽;허재성;문성욱;신현준;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.448-452
    • /
    • 2004
  • The micromachined variable optical attenuator(VOA) was presented in the paper. The VOA has two single mode fiber(SMF) aligned with free space and symmetric parallel plate actuator with microshutter, which can control a amount of light by driving the actuator. In the paper, analysis on driving performances of the VOA was performed and can be reduced threshold voltage through the decreasing displacement actuating range. This paper presents a VOA that is fabricated using bosch deep silicon etching process with silicon on insulator(SOD wafer. The VOA consists of driving electrode, ground electrode, actuating microshutter, and mechanical stopper. In this VOA, actuating shutter is driven by electrostatic force and the threshold voltage is close to 28V, 46V come along with the spring width of 5${\mu}{\textrm}{m}$, 7${\mu}{\textrm}{m}$ respectively. Attenuation range is measured from 2.4㏈ to 16.7㏈.

수직휜이 부착된 평행평판 채널내의 유동 및 열전달에 관한 수치해석 (Numerical Analysis of Fluid Flow and Heat Transfer in a Parallel-Plate Channel with Transverse Fins)

  • 황기영;김홍제;모정하
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.642-653
    • /
    • 1995
  • An analysis is made of the laminar fluid flow and heat transfer characteristics in a parallel-plate channel to whose walls are fitted with a series of equidistant staggered fins placed transversely to the flow direction. The governing equations are solved numerically by a finite-volume method for elliptic flows. Based on the obtained solutions of flow and temperature fields, the effects of Reynolds number and various geometric parameters on the heat transfer performance and pressure drop are evaluated. A comparson of the heat transfer characteristics between the channels with and without staggered fins is also made.

  • PDF

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

여유구동 병렬기구의 기구학적 보정 (Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms)

  • 정재일;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF