• Title/Summary/Keyword: Parallel Head

Search Result 128, Processing Time 0.03 seconds

Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

Intensity-modulated radiotherapy for stage I glottic cancer: a short-term outcomes compared with three-dimensional conformal radiotherapy

  • Cho, Ick Joon;Chung, Woong-Ki;Lee, Joon Kyoo;Lee, Min-Cheol;Paek, Jayeong;Kim, Yong-Hyub;Jeong, Jae-Uk;Yoon, Mee Sun;Song, Ju-Young;Nam, Taek-Keun;Ahn, Sung-Ja;Lee, Dong Hoon;Yoon, Tae Mi;Lim, Sang-Chul
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To investigate the differences in treatment outcomes between two radiation techniques, intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: We retrospectively analyzed 160 (IMRT = 23, 3DCRT = 137) patients with stage I glottic cancer treated from January 2005 through December 2016. The IMRT was performed with TomoTherapy (16 patients), volumetric-modulated arc therapy (6 patients), and step-and-shoot technique (1 patient), respectively. The 3DCRT was performed with bilateral parallel opposing fields. The median follow-up duration was 30 months (range, 31 to 42 months) in the IMRT group and 65 months (range, 20 to 143 months) in the 3DCRT group. Results: The 5-year overall survival and 3-year local control rates of the 160 patients were 95.7% and 91.4%, respectively. There was no significant difference in 3-year local control rates between the IMRT and 3DCRT groups (94.4% vs. 91.0%; p = 0.587). Thirteen of 137 patients in the 3DCRT group had recurrences. In the IMRT group, one patient had a recurrence at the true vocal cord. Patients treated with IMRT had less grade 2 skin reaction than the 3DCRT group, but this had no statistical significance (4.3% vs. 21.2%; p = 0.080). Conclusion: IMRT had comparable outcomes with 3DCRT, and a trend of less acute skin reaction in stage I glottic cancer patients.

A simple technique for repositioning of the mandible by a surgical guide prepared using a three-dimensional model after segmental mandibulectomy

  • Funayama, Akinori;Kojima, Taku;Yoshizawa, Michiko;Mikami, Toshihiko;Kanemaru, Shohei;Niimi, Kanae;Oda, Yohei;Kato, Yusuke;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.16.1-16.6
    • /
    • 2017
  • Background: Mandibular reconstruction is performed after segmental mandibulectomy, and precise repositioning of the condylar head in the temporomandibular fossa is essential for maintaining preoperative occlusion. Methods: In cases without involvement of soft tissue around the mandibular bone, the autopolymer resin in a soft state is pressed against the lower border of the mandible and buccal and lingual sides of the 3D model on the excised side. After hardening, it is shaved with a carbide bar to make the proximal and distal parts parallel to the resected surface in order to determine the direction of mandibular resection. On the other hand, in cases that require resection of soft tissue around the mandible such as cases of a malignant tumor, right and left mandibular rami of the 3D model are connected with the autopolymer resin to keep the preoperative position between proximal and distal segments before surgical simulation. The device is made to fit the lower border of the anterior mandible and the posterior border of the mandibular ramus. The device has a U-shaped handle so that adaptation of the device will not interfere with the soft tissue to be removed and has holes to be fixed on the mandible with screws. Results: We successfully performed the planned accurate segmental mandibulectomy and the precise repositioning of the condylar head by the device. Conclusions: The present technique and device that we developed proved to be simple and useful for restoring the preoperative condylar head positioning in the temporomandibular fossa and the precise resection of the mandible.

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.

A Study on the Use of 10 MV X-Ray with Lead Absorber for Treatment of Head and Neck Tumors (10MV X선(線)을 이용(利用)한 경부(頸部) 방사선(放射線) 치료시(治療時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kim, Hyung Sik;Kang, Wee Saing;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.25-28
    • /
    • 1983
  • Anterior and posterior parallel opposed field technique covering entire neck is desirable for elimination of junctional problems in treating upper neck with bilateral parallel opposed fields and lower neck with anterior one field. For good dose distribution in neck, dose in build-up region should be high for anterior field and should be low for posterior field. And so, with 10 MV X-ray, lead absorber was used for anterior field only. The adequate thickness of lead absorber, absorber-skin separation, width of central cord block for posterior field and anterior & posterior field weight were studied using film dosimery. The results are as follows. 1. As the thickness of the lead absorber increased the dose in build-up region increased. 2. As the absorber-skin separation decreased the dose in build-up region increased. 3. The adequate thickness of lead absorber was around 5.6mm. 4. The adequate absorber-skin separation was around 5cm. 5. The adequate posterior cord block width was 3cm. 6. 4:1 weighting for anterior and posterior field was adequate. And so with this technique, adequate dose distribution could be made as well as elimination junction problems.

  • PDF

A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger- (원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 -)

  • 이찬규;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.251-258
    • /
    • 1990
  • Optimal design of heat exchanger for closed CO$_{2}$ gas turbine plant of three processes selected from the result of cycle analysis have been discussed previously paper(I) has been carried out under specified inlet and outlet conditions. Independent variables such as number of parallel connection, tube diameter, shell side and tube side pressure loss as well as dependent variables such as shell diameter, number of tubes, number of serial connections were all characterized according to the standardization or so. Search method was used to construct a computer simulation together with the calculation of heat transfer rate by logarithmic mean temperature difference method. Strength analysis of major parts was carried to examine their dimensions satisfying heat transfer and pressure loss requirements.

The maxillary incisor labial face tangent: clinical evaluation of maxillary incisor inclination in profile smiling view and idealized aesthetics

  • Naini, Farhad B.;Manouchehri, Shaadi;Al-Bitar, Zaid B.;Gill, Daljit S.;Garagiola, Umberto;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.31.1-31.7
    • /
    • 2019
  • Background: To test the hypothesis that in profile smiling view, for ideal aesthetics, a tangent to the labial face of the maxillary central incisor crowns should be approximately parallel to the true vertical line and thereby perpendicular to the true horizontal line. Methods: An idealized female image was created with computer software and manipulated using the same software to construct an "ideal" female profile image with proportions, and linear and angular soft tissue measurements, based on currently accepted criteria for idealized Caucasian profiles. The maxillary incisor labial face tangent was altered in 5° increments from 70 to 120°, creating a range of images, shown in random order to 70 observers (56 lay people and 14 clinicians), who ranked the images from the most to the least attractive. The main outcome was the preference ranks of image attractiveness given by the observers. Results: The most attractive inclination of a tangent to the labial face of the maxillary incisor crowns in profile view in relation to the true horizontal line was 85°, i.e. 5° retroclined from a perpendicular 90° inclination. The most attractive range appears to be between 80 and 90°. Excessive proclination appeared to be less desirable than retroclination. Beyond 105° most observers recommend treatment. Conclusion: In natural head position, the ideal inclination of the maxillary incisor crown labial face tangent in profile view will be approximately parallel to the true vertical line and thereby approximately perpendicular to the true horizontal line.

An experimental study on influence of wearing seal groove shape to performance of the pump (마모 실 홈 형상이 펌프 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Jun-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.285-291
    • /
    • 2014
  • This paper is related to the improvement of efficiency for high performance centrifugal pumps by reducing leakage loss, which is achieved by applying the grooved seal as a non-contact seal to the pumps. Various combinations of grooved seal types, including the spiral and the parallel groove in the rotor and/or in the stator, were tested by the experiment. And the corresponding hydraulic performance and the magnitude of axial thrust were measured and calculated for ten cases. From the results, the type with the spiral groove(spiral angle : $0.98^{\circ}$) in both the rotor and the stator was found to be most effective. In this case, the head and the efficiency were improved from the original design by 2.1% and 2.3% respectively at design capacity($340m^3/h$), and the axial thrust was decreased by 10%.

A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD (인체 두부에서 Dynamic Tomogram의 응용에 관한 연구)

  • Choi Eui Whan;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF