• Title/Summary/Keyword: Parallel Head

Search Result 129, Processing Time 0.026 seconds

Numerical Study on the Inlet Head Configuration of Multi-Phase Separator for Modularization (다상유동 분리기 모듈화를 위한 유입구 형상 설계에 관한 수치해석적 연구)

  • Hong, Chang-Ki;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.9
    • /
    • pp.571-577
    • /
    • 2017
  • In this numerical study, the separation efficiency of three-phase separator in an oil-sand plant was studied with various inlet head configurations. The free water knockout (FWKO) vessel was designed with a flow rate of $15.89m^3/day$ (100 bbl/day) and the SOR(stream-to-oil ratio)=3.5 was derived using Stokes' law. For modularization, optimization of the design of the inlet head configuration was performed with parallel-connected dual FWKO vessels. The feed condition of bitumen emulsion was API=17, $T_{in}=150^{\circ}C$ and $P_{in}=50bar$. A mean residence time was determined the time when 95% of the oil and water in FWKO vessel was separated. The combination between the volume of fluid (VOF) and the discrete phase model (DPM) was used to simulate the phase separation phenomenon in a multi-phase separator. Furthermore, in order to calculate multi-phase flow the pseudo-transient method was adopted.

Effects of Neck and Pelvic Exercise Using Swiss Ball on Spinal Curve in Adults with Forward Head Posture (전방머리자세 대상자에 대한 목운동과 골반운동이 척추 굽이에 미치는 효과)

  • Bae, Won-Sik;Jang, Chel
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.193-201
    • /
    • 2021
  • Purpose : The purpose of this study was to compare the effect of pelvic exercise on the CVA and spinal curve in adults with forward head posture compared to the group using only neck exercise when pelvic exercise was performed in parallel with conventional neck exercise. Methods : GPS 400 and Formetric were used to identify craniovertebral angle (CVA), thoracic kyphosis, lumbar lordosis, and pelvic torsion and were measured by an experienced research manager. Forward head posture (FHP) was selected for people whose angle between the line connecting the ear ball and the seventh cervical spine and the horizontal line is 50 degrees or less. The 30 selected students were randomly divided into 15 experimental groups and 15 control groups. Mackenzie exercise and sling exercise were performed for neck exercise in both the experimental group and the control group, and pelvic exercise using a Swiss ball was additionally performed in the experimental group. All data collected in this study were analyzed using SPSS statistics 21.0. Cervical vetebral angle (CVA), thoracic kyphosis, lumbar lordosis, and pelvic torsion were compared at 0 weeks, 3 weeks, and 6 weeks for each measurement factor using ANOVA with repeated measures. For the statistical significance test, the significance level of α was set to .05. Results : The changes of pelvic torsion, thoracic kyphosis and CVA due to pelvic exercise using Swiss Ball and neck exercise were changed over time, but lumbar lordosis were not changed. And there were no significant differences among the groups. Conclusion : In conclusion, the pelvic correction exercise is considered to be an effective exercise for correcting the FHP and requires regular pelvic correction exercises. We expect the results to be used in clinical trials.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

A STUDY OF HOLOGRAPHIC INTERFEROMETRY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO THE MAXILLARY PROTRACTION USING THE ANTENNA TYPE MODIFIED PROTRACTION HEAD GEAR (Modified Protraction Headgear를 이용한 상악골 전방 견인시 악안면골의 초기반응에 관한 Holographic Interferometry 연구)

  • Lee, Kong-Geun;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.531-556
    • /
    • 1992
  • The majority of the commonly used protraction headgears for the protraction of small and/or retropositioned maxilla not allow a change in the point of force application or direction of the force delivery to attain predictable results because of the position of the upper and lower lips to avoid discomfort to the patient. The purpose of this study was to investigate the initial reaction of maxillofacial complex according to the change of force variables such as direction and point of force application with designing an antenna type-modified protraction head gear. A macerated human skull with well aligned upper teeth was used to experimental model and the investigation was done by double exposure holographic interferometry. Fringe patterns of each protraction conditions were compared and analized. The results were as follows. (Frontal view) 1. The Counterclockwise rotation of the maxilla was showed by parallel protraction to occlusal plane and the fringe was decreased in number as higher point of force application. 2. Generally, the number of fringe was increased in 500gm of protraction force than in 300gm. 3. When apply the protraction force to the maxilla with rapid palatal expansion, the direction of fringe patterns was differed from the protraction without expansion. 4. In most of cases, the counterclockwise rotation was decreased in case of the direction of the force is $20^{\circ}$ downward to occlusal plane compared to the parallel direction. 5. At the point of force application is 15mm above and the direction of force is 20 downward to occlusal plane , the translation of the maxillary complex was showed. (Lateral view) 6. The direction of fringe patterns of the facial bones were differed each other by the sutures, and showed almost parallel when apply the 300gm and 500gm of protraction force. 7. In case of rapid palatal expansion with protraction of the maxilla, the fringe patterns between the maxillary area and the area from the posterior of the maxillary first molar to the pterygomaxillary fissure were differed. In case without rapid palatal expansion, the changes of direction and point of the force application did not affect to the direction and the number of the fringe patterns.

  • PDF

Test of Headed Reinforcement in Pullout

  • Park, Dong-Uk;Hong, Sung-Gul;Lee, Chin-Yong
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.102-110
    • /
    • 2002
  • Results of an experimental study on the pullout behavior of the headed reinforcement are presented. A total of 48 pullout tests was performed to evaluate pullout strengths and load-displacement behaviors in pullout of the headed bars. The square steel heads had gross area of 4 $A_{b}$ and thickness of $d_{b}$ The test program consisted of three pullout test groups: Simple and Edge pullout tests using plain concrete slabs, comparison of pullout performances between the standard hooks and the headed reinforcement, and pullout tests of headed reinforcement using reinforced concrete columns. Test variables included concrete strengths ( $f_{c}$' = 27.1MPa, 39.1MPa), reinforcing bar diameters (D16~D29), embedment depths (6 $d_{b}$~12 $d_{b}$), edge conditions, column reinforcement, and single-vs.-multiple bar pullout. Test results revealed that the heads effectively provided the pullout resistances of the deformed bars in tension. The load-displacement behaviors were similar between the 90-degree hooks and the headed reinforcement. When a multiple number of headed bars installed with small head-to-head spacings was pulled out, reinforcement designed to run across the concrete failure surface in a direction parallel to the headed bars helped improve the pullout performances of the headed reinforcement.t.ement.t.

  • PDF

Inspection of Calandria Reactor Area of Wolsung NPP using Thermal Infrared and CCD Images (CCD와 적외선 열영상의 다중영상을 이용한 월성원자력발전소의 칼란드리아 전면부 점검)

  • Cho, Jai-Wan;Choi, Young-Soo;Kim, Chang-Hoi;Seo, Yong-Chil;Kim, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.711-714
    • /
    • 2002
  • Thermal infrared camera have poor image qualities compared to commercial CCD cameras, as in contrast, brightness, and. resolution. To compensate the poor Image quality problems associated with the thermal infrared camera, the technique of superimposing thermal infrared image into real ccd image is proposed. The mobile robot KAEROT/m2, loaded with sensor head system at the mast, is entered to monitor leakage of heavy water and thermal abnormality of the calandria reactor area in overhaul period. The sensor head system is composed of thermal infrared camera and cod camera In parallel. When thermal abnormality on observation points and areas of calandria reactor area is occurred, unusual hot image taken from thermal infrared camera is superimposed on real CCD image. In this inspection experiment, more accurate positions of thermal abnormalities on calandria reactor area can be estimated by using technique of mapping thermal infrared image into CCD image, which include characters arranged in MPOQ order.

  • PDF

Determining Optimal Locations of an Artificial Recharge Well using an Optimization-coupled Groundwater Flow Model (지하수 모델링 기법을 이용한 인공함양정 최적 위치 평가)

  • Lee, Hyeonju;Koo, Min-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.66-81
    • /
    • 2014
  • A Fortran program was developed to determine the optimal locations of an artificial recharge well. Three objective functions were considered: (1) maximizing the recovery rates, (2) maximizing the injection rates, and (3) minimizing the coefficient of variation of the increased pumping rates. We also suggested a new aggregate objective function which combined the first and the third objective functions. The model results showed that locating the injection well inside the cluster of pumping wells was desirable if either the recovery or the injection rate was taken into account. However, the injection well located outside the cluster evenly increased the pumping rates in existing pumping wells. Therefore, for clustered pumping wells, installing an injection well at the center or the upstream of the pumping wells seems beneficial. For linear arrangement of pumping wells parallel to the constant head boundary, locating the injection well in the upstream was recommended. On the contrary, in case of the linear arrangement perpendicular to the constant head boundary, the injection well installed on both sides of the central part of the pumping wells was preferable.

Two Cases of Mucosal Bridge Crossing the Membrane of Vocal Folds (양측 성문 점막 부위를 연결하는 성대 점막교(Mucosal Bridge) 2예)

  • Jung, Chan Min;Lee, Eun Jung;Lim, Jae-Yol;Choi, Hong-Shik
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.11
    • /
    • pp.619-623
    • /
    • 2018
  • Mucosal bridges of vocal fold have been described as a parallel band to vocal folds with the presence of sulcus vocalis. However, the type of mucosal bridge crossing each vocal fold has not been well documented in the literature. Herein, we present two cases of mucosal bridge found in the vocal fold connecting the mid-portions of true vocal folds. Two patients who had no history of laryngeal trauma, surgery or oro-tracheal intubation visited our clinic due to voice change. Laryngoscopic examination revealed that they had a mid-portion mucosal band without any other mucosal lesions. Two patients underwent laryngomicrosurgery with pulsed dye laser. After the surgery, they showed significant improvement of voice quality.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.