• 제목/요약/키워드: Parallel Flow Type

검색결과 146건 처리시간 0.025초

2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions)

  • 손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

450自由衝突 噴射 의 亂流流動 에 관한 實驗的 硏究 (An Experimental Study on the Turbulent Flow of a 45$^{\circ}C$ Free Cross Jet)

  • 노병준;김장권
    • 대한기계학회논문집
    • /
    • 제8권5호
    • /
    • pp.442-449
    • /
    • 1984
  • 본 연구에서는 두 분류가 교우되어 배합이 이루어지는 유동역에서 3차원 방향 에 대하여 평균속도분포, 난류강도분포, 난류전단응력분포, 상관계수의 분포 및 난류 운동에너지와 운동량의 변화 등을 측정 분석하였다.

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 - (A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-)

  • 이찬규;이종원
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.251-258
    • /
    • 1990
  • 본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.

차량에서 배출되는 대기 오염 물질의 빅 데이터에 대한 병렬 데이터 처리 모델의 강화 및 성능 최적화에 관한 연구 (A study on the enhancement and performance optimization of parallel data processing model for Big Data on Emissions of Air Pollutants Emitted from Vehicles)

  • 강성인;조성윤;김지환;김현정
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.1-6
    • /
    • 2020
  • 도로이동 오염원 대기환경 빅데이터는 상시 교통량 조사장비인 AVC, VDS, WIM, DTG를 활용한 차종, 속도, 하중 등 실시간 교통류 데이터와 GIS를 활용한 도로형상(오르막, 내리막, 회전구간) 데이터를 연계한 교통류 데이터로 구성되어 있다. 또한, 일반적인 데이터와 달리 단위시간 당 데이터가 많이 발생하고, 다양한 포맷을 가지고 있다. 특히, 이들 상세 교통류 정보로 수집되는 대용량의 실시간 데이터들은 약 총 740만 건/시간 이상이 수집되어 저장 및 가공되기 때문에 효율적으로 데이터를 처리할 수 있는 시스템이 필요하다. 따라서 본 연구에서는 도로이동 오염뭔 대기환경 빅데이터 시각화를 위한 오픈소스 기반의 데이터 병렬처리 성능 최적화 연구를 수행한다.

스크레이퍼형 아이스슬러리 제빙기의 열전달 특성 연구 (A Study on the Heat Transfer Characteristics of Ice Slurry Generator with Scraper)

  • 김민준;김종하;윤재호;박일환;조형석;안성국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1974-1979
    • /
    • 2007
  • In this study, Ice slurry generator heat transfer characteristics are experimentally investigated for the ice slurry generating system with scraper which is pneumatically operated. The ice slurry generator has the same shape as the vertical double tube type heat exchanger. Refrigerant is flowing in the outside tube and ethylene glycol solution in the inside tube. Refrigerant and solution water are parallel flow type which entering bottom of generator and leaving top of generator. The experimentations are conducted under the various test conditions such as compressor speed and cooling water temperature. For the above experimental conditions, heat transfer characteristics of the ice slurry generating system are evaluated in terms of the overall heat transfer coefficient and the heat transfer rate. And the experimental results show that the heat transfer rate of the system is increased as the compressor speed increases and the cooling water temperature decreases.

  • PDF

분리판식 유수분리기의 평행판 배열과 유수분리 효율에 관한 실험적 연구 (An Experimental Study on the Parallel plate Arrangement and Oil/water Separation Efficiency for Plate type Oily water Separator)

  • 한원희;김광수;이진열
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제4권2호
    • /
    • pp.52-60
    • /
    • 2001
  • 갈수록 강화되고 있는 해양오염 기준에 맞추어 유성 빌지 배출시 포함된 기름의 함유량을 제어하기 위한 방법 중의 하나로 중력 분리 방식의 유수분리기가 개발되어왔다. 중력분리 방식 중 분리판식 유수관리기는 고비중을 가진 다량의 농후유를 처리하는데 있어서 효과적이기 때문에, 현재 IMO 기준인 15ppm에 부합하는 필터여과방식의 보완장치로서 사용이 가능하다. 이 논고의 목적은 분리판의 배열에 따른 유수분리 효율에 대해 검토하는 것이다. 유량, 유입유분농도 그리고 분리판 사이의 간격 등을 포함한 여러 가지 운용상의 변수가 있는 유성혼합물에 대한 효율적인 처리를 알아보기 위해 실험적 연구를 수행하였다. 실험결과 얻은 결론에서 격리판 사이의 간격이 분리효율에 지대한 영향을 미치고 있음을 알 수 있었고, 가장 좋은 분리 효율은 분리판과 내통 사이 간격과의 비율(H/Ci)이 2일 때 유입유분농도가 낮고 유량이 작은 경우에 얻어졌다.

  • PDF

음파 가진을 이용한 2차원 웨이크 유동 제어에 관한 연구 (A study on 2-D wake flow control by acoustic excitation)

  • 김현진;김재호;김명균
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.860-873
    • /
    • 1998
  • In a low speed open-type wind tunnel, a group of parallel wakes downstream of two dimensional grid model consisting of several circular cylinders were experimentally investigated to study the response of the wake flows to the acoustic excitation, in hoping to promote the understanding of the underlying mechanism behind the gross flow change due to artificial excitation. In the unexcited wake flows, the development of the individual wakes behind cylinders was almost uniform for the ratio of the spacing to the cylinder diameter of s/d.geq.1.5. For smaller s/d, however, the jet streams issued through the gaps between the cylinders became biased in one side and the cylinders had wakes of different sizes. At s/d=1.25, the gap flow directions change in time, leading to unstable wake patterns. Further reduction in s/d made this unstable flip-flopping of the jets stable. The most effective excitation frequency was found to be in the Strouhal number range of St=0.5-0.6. This frequency was related to the vortex shedding. At s/d=1.75, the excitation frequency was 2 or 4 times the vortex shedding frequency. When the flow was excited at this frequency, the vortex sheddings were energized, and pairings between neighboring vortices were generated. Also, the merging process between individual wakes was accelerated. The unstable and unbalanced wake patterns at s/d=2.15 were made stable and balanced. The unstable and unbalanced wake patterns at s/d=2.15 were made stable and balanced. For smaller spacing of s/d .leq,1.0, the acoustic excitation became less effective in controlling the flow.

용암류 특성에 의한 제주도 폭포의 유형화 (Classification of Waterfalls in Jeju Island Based on Properties of a Lava Flow)

  • 김태호
    • 한국지역지리학회지
    • /
    • 제18권2호
    • /
    • pp.129-140
    • /
    • 2012
  • 제주도 폭포의 지형 특성을 파악하기 위하여 한라산 산록과 서귀포 해안지대에 소재하는 26개 폭포를 대상으로 용암류의 형태와 물리적 성질에 의해 폭포를 분류하고, 후퇴프로세스를 검토하였다. 폭포벽과 폭호를 구성하고 있는 용암류 유형과 매수에 근거하여 단일 용암류형, 복수 용암류형, 기저부 연암형 및 용암류 암괴형으로 유형화할 수 있다. 단일 용암류형 폭포는 조면암이나 조면안산암 분포지역에, 복수 용암류형 폭포와 기저부 연암형 폭포는 현무암이 나 조면현무암 분포지역에 잘 발달하여 폭포 유형에 용암류의 암질이 반영되고 있다. 폭포의 후퇴프로세스는 단일 용암류형 폭포에서는 감경사적 후퇴나 교체후퇴가 나타나는 반면 기저부 연암형 폭포는 전형적인 평행후퇴를 한다. 복수 용암류형 폭포는 용암류의 물리적 성질에 따라 세 후퇴 유형을 모두 보인다. 수직절리가 잘 발달한 용암류가 폭포벽을 만들고 있으므로 대부분의 폭포는 수직에 가까운 폭포벽을 지닌다.

  • PDF

단일 균열 평판 모델에서 가스-물 균열 상대투과도 측정에 관한 실험적 연구 (Experimental Study on Gas-Water Fracture Relative Permeability Measurement in a Single-Fractured Parallel Plate Model)

  • 이원석;성원모;한일영
    • 한국지반공학회논문집
    • /
    • 제16권1호
    • /
    • pp.221-226
    • /
    • 2000
  • 단일 균열시스템에서 간극 크기에 따른 상대투과도의 변화 특성을 측정하기 위해 본 연구에서는Hele-Shaw평판 형태의 유리 평판을 제작하여 실험을 수행하였다. 평판의 재질은 유동 양상 관찰을 위해 유리를 사용하였고, 간극 크기는 실제 현장에서 관측되는 30에서 $120\mum$ 사이의 범위에서 7가지 경우를 설정하여 정상유동법에 의한 실험을 수행하였다. 또한 실험 측정결과에 대한 보다 정확한 포화도 계산 및 분석의 편의를 위해 디지털 영상 편집법 (digital image process technique)을 이용한 해석모델을 개발ㆍ이용하였으며, 균열에서의 2상 유체유동 양상에 직접적인 영향을 미치는 간극크기와 매질의 표면 특성을 나타내는 임계포화도를 이용하여 단일 균열에 대한상대투과도 실험관계식을 도출하였다.

  • PDF