• Title/Summary/Keyword: Paper reduction

Search Result 10,302, Processing Time 0.035 seconds

The Mechanical Properties of Concrete Usinga Large Amount of Fly Ash for Replacement Method (치환방법에 따른 플라이애쉬를 다량 치환한 콘크리트의 공학적 특성)

  • Kim, Tae-Wan;Kim, Tae-Sik;Jin, Chi-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.105-113
    • /
    • 2006
  • This paper presents the results of an experimental investigation carried out to evaluate the mechanical properties of concrete mixtures in which fine(S) and coarse(G) aggregate was fully replaced with fly ash(FA). And flowability reduction problem in a large amount of fly ash concrete settled addition water($W_f$) in concrete mixture. In the test, water-cement ratio($W_c/C$) was 0.35, 0.45, and water-fly ash ratio($W_f/FA$) was 0.35, 0.45. The fly ash replacement is two different method of P and Q. The P method is mix property that the fly ash and addition water($W_f$) weight is equal to the aggregate weight [ $FA+W_f$ = G (or S)]. The Q method is mix property that fly ash is equal to aggregate weight, and added addition water($W_f$) [$FA+W_f$ > G (or S)]. Test were performed for properties of fresh concrete and compressive strength were determined at 3, 7, 28 and 91 days. The result, compressive strength was improvement that $W_c/C=0.35$, $W_f/FA=0.35$ and fine aggregate replacement in P method series than others. The flowability at Q method was improvement result than P method, but compressive strength was not. Test results indicate significant improvement in the strength properties and flowability of plain concrete by the inclusion of fly ash as fully replacement of fine and coarse aggregate, and can be effectively the fly ash replacement method.

Spalling Properties of the High Strength Concrete Containing PP Fiber Subjected to Fire Mixture Factors and Drying Condition (배합요인 및 건조상태 변화에 따른 PP섬유 혼입 고강도 콘크리트의 폭렬특성)

  • Han, Cheon-Goo;Han, Min-Cheol;Song, Yong-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.115-122
    • /
    • 2008
  • This paper is to investigate the affecting factors on spalling of the high strength concrete including W/B, air content and moisture condition as well as PP fiber contents subjected to fire. An increase with 0.05% of PP fiber resulted in a reduction of slump flow by as much as 11%. Ten percent of air contents due to excessive amounts of AE agent does not lead to variance of slump flow, regardless of PP fiber content. For the effect of the compressive strength, high strength concrete with 15, 25 and 35% of W/B gained 60 MPa~100 MPa of the compressive strength. High strength concrete with H-air had half of compressive strength of that with L-air due to large amount of air. Fire test was conducted in accordance with KS F 2257-1 for 1 hour. Spalling did not occur with all specimens containing more than 0.10% of PP fiber except those with 15% of W/B. Moreover, it is interesting to note that the specimens with more than 10% of air content and with oven dried condition, respectively, had no spalling even if the content of PP fiber is 0.05 vol.%.

Audit by Big4 Accounting Firms and Earnings Management of Shipping Companies (Big4 회계법인의 감사와 해운사의 이익조정)

  • Soon-Wook Hong
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.321-326
    • /
    • 2024
  • The purpose of this study is to investigate whether Big 4 accounting firms contribute to the reduction of earnings management when auditing shipping companies. Generally, it is understood that companies audited by the Big 4 accounting firms engage in minimal earnings management and maintain high audit quality. However, these factors may vary depending on industry and firm size. As a result, this study empirically analyzes the impact of audits conducted by large accounting firms on earnings management within the shipping industry. The Big 4 accounting firms, namely PwC, KPMG, Deloitte, and EY, are the focus of this research. Discretionary accruals are employed as a proxy for earnings management, with the modified J ones model and the performance matched model used to measure discretionary accruals. The analysis, which covers shipping companies listed on KOSP I from 2001 to 2023, reveals that audits conducted by the Big 4 accounting firms do not significantly influence earnings management in the shipping industry. Unlike the general case, it is evident that audits by the Big 4 accounting firms do not play a role in reducing earnings management in shipping companies. This paper is significant as it examines the role of auditors within the shipping industry and presents findings that deviate from commonly known information. Shipping companies should take into consideration that the audit quality of the Big 4 accounting firms may not always be guaranteed when selecting an auditor. Furthermore, supervisory authorities such as the Financial Supervisory Service should engage in oversight based on an accurate understanding of the audit quality offered by the Big 4 accounting firms.

Sound Pressure and Vibration Characteristics of Reinforced Concrete Slab with Heavy Weight Mortar for Cross-section Recovery (단면 회복용 중량 모르타르를 사용한 철근콘크리트 슬래브의 음압 및 진동 특성)

  • Jae-Sung Kim;Jin-Man Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.3
    • /
    • pp.298-305
    • /
    • 2024
  • This paper is a basic study to improve floor impact noise of reinforced concrete slabs. Considering the case where thickness differences occur due to construction, changes in sound insulation characteristics were analyzed when the cross section of a reinforced concrete slab was restored with mortar. The houses subject to analysis were divided into two types, 84 type and 59 type, with different floor plans. When pre-mortaring was done with heavy mortar to restore the cross section on the reinforced concrete slab, the case was when pre-mortaring was done with the reinforced concrete slab alone and with general mortar. Compared with, the difference between vibration acceleration level and sound pressure was measured. As a result of measuring the vibration acceleration level of the slab after pouring the mortar, the CS mortar was 66.4 dB and the ES mortar was 66.1 dB at 84 type 63 Hz, which was more than 2 dB lower than that of regular mortar. In addition, compared to the reinforced concrete slab alone, CS mortar was reduced by 5.5 dB and ES mortar was reduced by 4.6 dB, showing relatively excellent values. As for the floor impact sound pressure, the 84B type was similar at 63 Hz for CS mortar and general mortar at 67.3 dB, and the reduction compared to the reinforced concrete slab alone was 3.6 dB for CS mortar, 2.7 dB for ES mortar, and 2.7 dB for general mortar was reduced by 1.4 dB. By pouring mortar to compensate for the thickness of the reinforced concrete slab, the vibration acceleration level and floor impact noise were reduced, and when a heavy mortar using copper smelting slag fine aggregate was used, relatively excellent performance was found.

Citation Trend and Suggestions for Improvement of Impact Factor of Journal of Korean Therapeutic Radiology and Oncology (대한방사선종양학회지의 학술인용 변화 추이 및 학술 영향력 지수 개선을 위한 제안: 한국의학학술지 인용색인 자료 분석)

  • Kim, Seong-Hwan;Ahn, Myeong-Im;Jeong, So-Na;Hwang, Seong-Su
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.309-316
    • /
    • 2006
  • $\underline{Purpose}$: To analyze the recent citation trend and to find a way to improve impact factor (IF) of the Journal of Korean Therapeutic Radiology and Oncology (JKSTRO) by analysis of Korean Medical Citation Index (KoMCI) citation data of JKSTRO and comparison with that of mean citation data of all journals enlisted on KoMCI (KoMCI journals) during 2000-2005. $\underline{Materials\;and\;Methods}$: All citation data of entire journals enlisted on KoMCI and JKSTRO from 2000 to 2005 were obtained from KoMCI. The trend of total and annual number of published articles and reference citations, total citations and self-citations per paper, IF and impact factor excluding self-citations (ZIF) were described and compared on both KoMCI journals and JKSTRO. $\underline{Results}$: Annual number of published articles was decreased for 6 years on both KoMCI journals and JKSTRO (32% and 38% reduction rate). The number of Korean journal references per article is 1.6 papers on JKSTRO comparing to 2.0 papers on KoMCI journals. The percentage of Korean references/total references increased from 5.0% in 2000 to 7.7% in 2005 on JKSTRO and from 8.5% in 2000 to 10.1% on KoMCI journals. The number of total citations received/paper on JKSTRO (average 1.333) is smaller than that of KoMCI journals (average 1.694), there was an increased rate of 67% in 2005 comparing to 2000. The percentage of self-citations/total citations (average 72%) on JKSTRO is slightly higher than that of KoMCI journals (average 61%). IF of JKSTRO was gradually improved and 0.144, 0.125, 0.088, 0.107, 0.187, and 0.203 in 2000-2005 respectively. However, ZIF of JKSTRO is steadily decreased from 0.038 in 2000 to 0.013 in 2005 except 0.044 in 2004. $\underline{Conclusion}$: IF of JKSTRO was slightly improved but had some innate problem of smaller number of citations received. To make JKSTRO as a highly cited journal, the awareness of academic status of JKSTRO and active participation of every member of JKSTRO including encouraging self-citations of papers published recent 2 years and submission of English written papers, and active academic cooperation with related academic societies.

Local Shape Analysis of the Hippocampus using Hierarchical Level-of-Detail Representations (계층적 Level-of-Detail 표현을 이용한 해마의 국부적인 형상 분석)

  • Kim Jeong-Sik;Choi Soo-Mi;Choi Yoo-Ju;Kim Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.11A no.7 s.91
    • /
    • pp.555-562
    • /
    • 2004
  • Both global volume reduction and local shape changes of hippocampus within the brain indicate their abnormal neurological states. Hippocampal shape analysis consists of two main steps. First, construct a hippocampal shape representation model ; second, compute a shape similarity from this representation. This paper proposes a novel method for the analysis of hippocampal shape using integrated Octree-based representation, containing meshes, voxels, and skeletons. First of all, we create multi-level meshes by applying the Marching Cube algorithm to the hippocampal region segmented from MR images. This model is converted to intermediate binary voxel representation. And we extract the 3D skeleton from these voxels using the slice-based skeletonization method. Then, in order to acquire multiresolutional shape representation, we store hierarchically the meshes, voxels, skeletons comprised in nodes of the Octree, and we extract the sample meshes using the ray-tracing based mesh sampling technique. Finally, as a similarity measure between the shapes, we compute $L_2$ Norm and Hausdorff distance for each sam-pled mesh pair by shooting the rays fired from the extracted skeleton. As we use a mouse picking interface for analyzing a local shape inter-actively, we provide an interaction and multiresolution based analysis for the local shape changes. In this paper, our experiment shows that our approach is robust to the rotation and the scale, especially effective to discriminate the changes between local shapes of hippocampus and more-over to increase the speed of analysis without degrading accuracy by using a hierarchical level-of-detail approach.

Study of Motion Effects in Cartesian and Spiral Parallel MRI Using Computer Simulation (컴퓨터 시뮬레이션을 이용한 직각좌표 및 나선주사 방식의 병렬 자기공명 영상에서 움직임 효과 연구)

  • Park, Sue-Kyeong;Ahn, Chang-Beom;Sim, Dong-Gyu;Park, Ho-Chong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Purpose : Motion effects in parallel magnetic resonance imaging (MRI) are investigated. Parallel MRI is known to be robust to motion due to its reduced acquisition time. However, if there are some involuntary motions such as heart or respiratory motions involved during the acquisition of the parallel MRI, motion artifacts would be even worse than those in conventional (non-parallel) MRI. In this paper, we defined several types of motions, and their effects in parallel MRI are investigated in comparisons with conventional MRI. Materials and Methods : In order to investigate motion effects in parallel MRI, 5 types of motions are considered. Type-1 and 2 are periodic motions with different amplitudes and periods. Type-3 and 4 are segment-based linear motions, where they are stationary during the segment. Type-5 is a uniform random motion. For the simulation, Cartesian and spiral grid based parallel and non-parallel (conventional) MRI are used. Results : Based on the motions defined, moving artifacts in the parallel and non-parallel MRI are investigated. From the simulation, non-parallel MRI shows smaller root mean square error (RMSE) values than the parallel MRI for the periodic (type-1 and 2) motions. Parallel MRI shows less motion artifacts for linear(type-3 and 4) motions where motions are reduced with shorter acquisition time. Similar motion artifacts are observed for the random motion (type-5). Conclusion : In this paper, we simulate the motion effects in parallel MRI. Parallel MRI is effective in the reduction of motion artifacts when motion is reduced by the shorter acquisition time. However, conventional MRI shows better image quality than the parallel MRI when fast periodic motions are involved.

  • PDF

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

The Situation and the Tasks of UK Rail Privatization, Focusing on after the Hatfield Accident (영국 철도 민영화의 현황 및 과제 (Hatfield사고 이후의 변화를 중심으로))

  • Lee, Yong-Sang
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.2 s.88
    • /
    • pp.91-100
    • /
    • 2006
  • This paper examines the situation and tasks of UK rail privatization, especially focusing on after the Hatfield rail accident. Earlier research which focused on the UK's Privatization had little knowledge of the explanations for recent changes. Moreover they had difficulty making a direct comparison between national rail and the privatized rail. Therefore we aye left without a good explanation which has a comprehensive perspective. I attempt to show the change in the rail privatization Process and its outcome, focusing on after the Hatfield rail accident. This Paper argues that the UK's vail privatization process has a regulatory framework which is too complicated with overlapping responsibilities that brought about inefficiency, increasing costs and a superficial safety regime. Especially the planning of rail and infrastructure maintenance did not come to play an appropriate role. However after 2000, the government took charge of setting the strategy for railways, and the Office of Rail Regulation covered safety performance and cost. explain that these changes present a good opportunity to solve the problem of passing the buck for poor performance. Through the analysis, I find that the passenger rail network is well-suited to deliver long distance business and commuters and that the subsidy from the government is decreasing. However, performance, for example punctuality and reliability. should be improved. Especially the Hatfield rail accident caused a reduction in the satisfaction of passengers. In future. the problems of rising costs and monopoly franchise system should be addressed.

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF