• Title/Summary/Keyword: Paper and salt

Search Result 514, Processing Time 0.165 seconds

Retention and Drainage Characteristics with Inverse Emulsion Type C-PAM

  • Son, Dong-Jin;Kim, Bong-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.5 s.118
    • /
    • pp.24-30
    • /
    • 2006
  • This study was performed to characterize inverse emulsion type cationic polyacrylamide (PAM) and to compare with powder and salt dispersion type PAMs as a retention and drainage aid. Salt dispersion type PAM has defects of high amount of salt which increases conductivity of white water, low active polymer contents and relatively worse retention and drainage properties than others because of its low molecular weight. Powder type PAM has benefit of high active polymer contents and good retention and drainage properties, but defects of low dissolution speed and insoluble particle generation were observed. However, inverse emulsion type showed the best retention and drainage aids among them by controlling molecular weight and morphology easily and it had relatively higher active polymer contents and better solubility.

Acoustic Emission Characteristics of Plasma Sprayed Ceramic Coating Layer after Salt Spray (플라즈마용사 세라믹코팅 피막부식재의 음향방출 특성)

  • 김귀식;박경석;홍용의
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.344-349
    • /
    • 2001
  • This paper was to investigate of a adhesiveness for the plasma sprayed coating materials did salt spray by acoustic emission method in tensile loadings. The powders used for the coating were nickel aluminum composite powder Ni-4,5wt.%Al and titanium dioxide powder Ti02. These powders were coated on a carbon steel S45C by plasma spray method. The salt solution was a 5% NaCl and the salt spray times were 2, 5 and 10 hours respectively. The salt solution penetrated into the surface of the substrate through pore of the coating layer built in the process of plasma spay. Corrosion productions formed on the surface of substrate. The adhesiveness between the substrate and the coating layer is weaken by corrosion and the exfoliation initiated chiefly at the corrosion surface of the substrate. The AE events and energy of the corroded coating specimens decreased as the salt spray times increased.

  • PDF

An Experimental Study on the Salt Damage Resistance of High Durable Concrete (고내구성콘크리트의 염해저항성에 관한 실험적 연구)

  • Yoon, Jai-Hwan;Jaung, Jae-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.3
    • /
    • pp.73-81
    • /
    • 2003
  • In this paper, salt damage resistance of high durable concrete was tested. High durable concrete was made by using low water cement ratio, chemical admixture called super-durable admixture and mineral admixtures such as fly-ash, ground granulated blast-furnace slag, silica fume. Two kinds of salt damage resistance test were carried out. One method is chloride ion penetration test(ASTM C1202), and the other one is depth of chloride penetration test in saline solution. Test results were as followers: 1) The depth of chloride ion penetration increased exponentially as water cement ratio was increased and time passed. 2) Super-durable admixture had little effect on the improvement of salt damage resistance of concrete. 3) Silica fume and ground granulated blast-furnace slag were effective on salt damage resistance because of pozzolanic reaction, but fly-ash had a little effect.

The Distribution Characteristics of Salt Contaminants in West Coast Region with the Distance from Sea (해안도달 거리에 따른 서해안 지역 염해 오손물의 분포특성)

  • Choi, Nam-Ho;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.276-280
    • /
    • 2001
  • This paper presents the result of a study on the distribution characteristics of salt contaminants in the west coast region, from Inchon to Yearsoo, of South Korea. To evaluate the distribution characteristics of salt contaminants, we had measured the equivalent salt deposit density(ESDD) with brush wiping method for thirteen month(from May 1999 to June 2000). Under the consideration on the measuring interval and method, normalization method was applied for the ESDD data. Besides the measurement, the chemical analysis (chromatography) was carried to investigate the relationship, between the electrical property and the amount of specific ingredient, such as sodium, magnesium and chloride. From the result, we could get the representative value of contamination for each site and distribution characteristics of salt contaminants with the distance from sea in the west coast.

  • PDF

A Surface Aging Characteristics of Silicone Rubber by Boiling in Salt Water (Salt Water Boiling에 의한 Silicone Rubber의 표면열화특성)

  • Han, S.I.;Yu, S.D.;Lee, B.S.;Yoon, J.Y.;Park, K.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1497-1499
    • /
    • 1997
  • This paper dealt with the surface aging characteristics of silicone rubber used as the surface material of outdoor polymer insulators under accelerated aging condition. There are many aging factors in natural environment. In this paper, the silicone rubber were accelerated to evaluate their performance against salt fog, that is, they were dipped in pure water and salt water under boiling condition. Then, contact angle and SEM(Scanning Electron Microscope) were used to estimate surface hydrophobicity, and dielectric loss($tan{\delta}$) and surface leakage current were measured to observe the electrical characteristics.

  • PDF

Study on Salt-Proof Characteristics of Copper Clad Aluminum (동복알루미늄의 내염특성 연구)

  • Kim, Jin-Sa;Bae, Duck-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1764-1768
    • /
    • 2009
  • As the demand of electric power is increasing rapidly, the need of the compact and light electric power device is also increased. Copper clad aluminum (CCA) is newly proposed electrical conductor, because of its light-weight and low-cost characteristics, to replace the existing conductor made of copper. This paper presents the salt-proof characteristics of the copper clad aluminum (CCA) to certificate long time safe operation of the newly proposed electrical conductor. The two types of the CCA conductor were tested in the neutral salt spray tester. The experimental results of two types of the CCA with salt spray were presented in this paper. The results comprise resistance measured data, micro picture of the selected surface, and component measured data according to the elapsed time. The period of the experiment was 1,000 hours. There was no evidence to show the corrosion of CCA during the whole period of the experiments.

A Detection of Salt Contamination on the Transmission Line Insulator Using Conductivity Sensor (전도도 센서를 이용한 송전선용 애자의 염분량 검출)

  • Kang, Y.W.;Shim, E.B.;Kweon, D.J.;Kwak, J.S.;Jung, C.S.;Lee, O.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.189-193
    • /
    • 2002
  • Outage caused by contaminated insulator on high voltage transmission line and in substation is major concern for utility world-wide. To prevent these outages, it is necessary to develop an automatic salt contamination detecting device which provide the information about contamination level on utility for engineer to meet the emergency in advance. For that purpose, we have been developing an automatic salt contamination detecting device to monitor a salt amount on operating power utility area. In the salt contamination detecting device development, the most important thing is the sensor which can detect a salt amount and the understanding of sensor' s detecting principle. This paper describes the operating principle of the sensor and the experimental results about the detecting of salt amount. The results of this experiment wi1l be useful for detecting the contamination level.

  • PDF

A Study on the Laser Salt-meter (II) (활선염해 측정장치 개발연구 (II))

  • Kim, H.J.;Jin, Y.S.;Lee, H.S.;Yoon, J.Y.;Joo, B.S.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1347-1349
    • /
    • 1995
  • Insulators contaminated by salt particles may cause flashovers in humid climate or light rain. Therefore, the quantity of salt on insulators should be monitored not to exceed a critical value. We propose a new remote sensing technique to measure the quantity of salt on insulators of power systems. The amount of the salt is measured from the intensity of the spontaneous emission from the sodium atoms. In this paper, a compact remote on-line salt-meter composed of Q Switch pulsed Nd:YAG laser and emission signal detection system will be introduced. And as the first result of this study, the operating characteristics of our developing laser system is also introduced.

  • PDF

Salt and Pepper Noise Removal using 2-Dimensional Spline Interpolation (2차원 스플라인 보간법을 이용한 Salt and Pepper 잡음 제거)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1167-1173
    • /
    • 2017
  • As the society increasingly embraces the high - tech digital information age, the field of image processing becomes progressively more branched out and becoming an imperative field. However, image data is deteriorated due to various causes during transmission and salt and pepper noise is typical. Typical methods for removing salt and pepper noise include CWMF, SWMF, and A-TMF. However, existing methods are somewhat insufficient in their ability to remove noise in salt and pepper noise environments. Therefore, in this paper, after it is determined whether noise removal is needed, the following measures were taken. If the center pixel was non-noise, the original pixel was preserved, If it was noise, we proposed a two - dimensional spline interpolation method and a median filter depending on the noise density of the local mask. For the purpose of objective judgment, we compared the results with that of existing methods and used PSNR (peak signal to noise ratio) as a judgment criterion.

A Study on the Modified Adaptive Median Filter for Removing Salt and Pepper Noise (Salt and Pepper 잡음 제거를 위한 변형된 적응 메디안 필터에 관한 연구)

  • Hong, Sang-Woo;Hwang, Yeong-Yeun;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.903-905
    • /
    • 2015
  • The need for digital devices is increasing in the digital age. In general, noise in images occurs during the process of compression, recognition and processing due to many reasons. Some of the filters used to remove salt and pepper noise include SMF, CWMF and AMF. In areas where the noise density is high, the removal of noise is undermined. This paper suggests an adjusted median filter algorithm that preserves the non-noise pixels while transforming the noise pixels to more effectively remove salt and pepper noise.

  • PDF