• 제목/요약/키워드: Panoramic radiography

검색결과 297건 처리시간 0.023초

파노라마방사선사진 지수와 임플란트 실패와의 관계에 관한 연구 (The relationships between panoramic indices and dental implant failure)

  • 조현정;이원진;허민석;안창현;이진구;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Purpose: Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. Materials and Methods: A case-control study was designed. Test group (n=42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n=139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. Results: The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Conclusion: Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  • PDF

The Efficacy of the Graft Materials after Sinus Elevation: Retrospective Comparative Study Using Panoramic Radiography

  • Jeong, Tae Min;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권4호
    • /
    • pp.146-153
    • /
    • 2014
  • Purpose: This study compares and evaluates the efficacy of graft materials after maxillary sinus bone grafts with autogenous tooth bone graft material (AutoBT), demineralized freeze-dried bone allograft (DFDBA) and deproteinized bovine bone mineral (DBBM). Methods: The study involved 30 sinuses in 26 patients who visited the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital and received either AutoBT, DFDBA or DBBM with sinus elevation using the lateral window technique. Sinus graft height was measured before, immediately after, and six months after bone graft with panoramic radiography and the height changes of the sinus floor was compared according to the graft materials. Results: After six months, the decrease ratio of graft heights were 13.57% for AutoBT group, 14.30% for DFDBA group, and 11.92% for DBBM group. There was no statistically significant difference. Conclusion: The new maxillary sinus floor formed by the upper border of bone graft material, can repneumatize after the maxillary sinus elevation. Thus, long-term stability of sinus graft height represents an important factor for implant success. We found that the three graft materials for sinus elevation do not differ significantly and all three graft materials showed excellent resistance to maxillary sinus repneumatization. However, due to the special circumstances of the maxillary sinus and small sample, the actual difference between the three graft materials may not have been detectable. Therefore further study needs to be conducted for more reliable study results.

A comparative study of cone-beam computed tomography and digital panoramic radiography for detecting pulp stones

  • Tassoker, Melek;Magat, Guldane;Sener, Sevgi
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.201-212
    • /
    • 2018
  • Purpose: The aim of this study was to compare cone-beam computed tomography (CBCT) and digital panoramic radiography (DPR) for the detection of pulp stones. Materials and Methods: DPR and CBCT images of 202 patients were randomly selected from the database of our department. All teeth were evaluated in sagittal, axial, and coronal sections in CBCT images. The systemic condition of patients, the presence of pulp stones, the location of the tooth, the group of teeth, and the presence and depth of caries and restorations were recorded. The presence of pulp stones in molar teeth was compared between DPR and CBCT images. Results: Pulp stones were identified in 105 (52.0%) of the 202 subjects and in 434 (7.7%) of the 5,656 teeth examined. The prevalence of pulp stones was similar between the sexes and across various tooth locations and groups of teeth (P>.05). A positive correlation was observed between age and the number of pulp stones(${\rho}=0.277$, P<.01). Pulp stones were found significantly more often in restored or carious teeth (P<.001). CBCT and DPR showed a significant difference in the detection of pulp stones(P<.001), which were seen more often on DPR than on CBCT. Conclusion: DPR, as a 2D imaging system, has inherent limitations leading to the misinterpretation of pulp stones. Restored and carious teeth should be carefully examined for the presence of pulp stones. CBCT imaging is recommended for a definitive assessment in cases where there is a suspicion of a pulp stone on DPR.

The relationship between masseter muscle thickness measured by ultrasonography and facial profile in young Korean adults

  • Park, Kyeong-Mee;Choi, Eunhye;Kwak, Eun-Jung;Kim, Seoyul;Park, Wonse;Jeong, Jin-Sun;Kim, Kee-Deog
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.213-221
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the relationship between masseter muscle thickness, facial morphology, and mandibular morphology in Korean adults using ultrasonography. Materials and Methods: Ultrasonography was used to measure the masseter muscle thickness bilaterally of 40 adults(20 males, 20 females) and was performed in the relaxed and contracted states. Facial photos and panoramic radiography were used for morphological analyses and evaluated for correlations with masseter muscle thickness. We also evaluated the correlations of age, body weight, stature, and body constitution with masseter muscle thickness. Results: In the relaxing, the masseter was $9.8{\pm}1.3mm$ in females and $11.3{\pm}1.2mm$ in males. In the contracted state, it was $12.4{\pm}1.4mm$ in females and $14.7{\pm}1.4mm$ in males. Facial photography showed that bizygomatic facial width over facial height was correlated with masseter muscle thickness in both sexes in the relaxed state, and was statistically significantly correlated with masseter muscle thickness in males in the contracted state. In panoramic radiography, correlations were found between anterior angle length and posterior angle length and masseter muscle thickness in females, and between body length and posterior angle length, between anterior angle length and body length, between ramal length and body length, and between body length and condyle length in males. Conclusion: Masseter muscle thickness was associated with facial and mandibular morphology in both sexes, and with age in males. Ultrasonography can be used effectively to measure masseter muscle thickness.

탈단백 우골과 제3인산칼슘을 이용한 상악동 골이식 후 이식재의 높이 변화 - 파노라마 방사선 사진을 이용한 후향적 대조 연구 (THE GRAFT HEIGHT CHANGES AFTER SINUS AUGMENTATION PROCEDURES USING DEPROTEINIZED BOVINE BONE MINERAL AND BETA-TRICALCIUM PHOSPHATE - A RETROSPECTIVE COMPARATIVE STUDY USING PANORAMIC RADIOGRAPHY)

  • 김종식;박태일;서현수;송윤정;홍순민;최미라;박준우
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권4호
    • /
    • pp.468-474
    • /
    • 2008
  • Purpose: Previous clinical investigations of sinus floor augmentation have demonstrated repneumatization of grafted sinus. The aim of this study is to evaluate and compare the height changes of sinus floor after grafting with deprotenized bovine bone mineral (DBBM) and beta tricalcium phosphate (TCP). Materials and methods: 34 sinuses in 28 patients were augmented with 100% DBBM or 100% TCP through lateral approaches. Sinusgraft height was measured before, immediately after, and 6 months after bone graft with panoramic radiography. Result: After 6 months, the decreases of graft heights were 14.53% for DBBM group and 15.15% for TCP group. There was no statistically significant difference. Discussion and Conclusion: Long-term stability of sinus-graft height represents an important factor for implant success. After the uses of DBBM and TCP for maxillary sinus floor augmentations, acceptable graft height maintenances were observed.

파노라마방사선사진을 이용한 연령별 하악 피질골 두께에 관한 연구 (The relationship between age and the mandibular cortical bone thickness by using panoramic radiograph)

  • 김윤숙;김경아;고광준
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.83-87
    • /
    • 2010
  • Purpose : This study was to determine the relationship between age and the mandibular cortical bone thickness on panoramic radiograph. Materials and Methods : Panoramic radiographs of 360 patients (180 men and 180 women) over 20 years old, who visited the Chonbuk National University Hospital from January to December in 2007, were assessed. The subjects were divided into 5 age groups. Five indices such as cortical bone thickness at the gonion (GI), antegonion (AI), and below the mental foramen (MI), the panoramic mandibular index (PMI), the mandibular cortical index (MCI) were measured on panoramic radiographs. Results : All five indices including GI, AI, MI, PMI, and MCI showed significant differences between third decade and over 8 decade groups (p<0.05). PMI, MI and GI showed significant differences with gender statistically (p<0.05). Conclusion : The mandibular cortical bone thickness showed negative correlation with age, and the value of the thickness (PMI, MI, and GI) was greater in men than in women.

Perceptions and attitudes of dental hygienists toward radiation safety and protection in the Republic of Korea

  • Yun, Kwidug;Lee, Kyung-Min;An, Seo-Young;Yoon, Suk-Ja;Jeong, Ho-Gul;Lee, Jae-Seo
    • International Journal of Oral Biology
    • /
    • 제46권4호
    • /
    • pp.168-175
    • /
    • 2021
  • To investigate the perceptions and attitudes of dental hygienists toward radiation safety management in Korea. A total of 800 dental hygienists were randomly selected for an anonymous survey, and 203 of them participated. The questionnaire items included the following: sex, career period, type of installed radiographic equipment, recognition of the diagnostic reference level (DRL), participation in radiation safety education, and attitudes toward radiation protection for both patients and dental hygienists. The participants were divided into two groups according to their years of experience (< 10 years versus ≥ 10 years). The difference between the groups was investigated according to frequency distribution. Fisher's exact test or Pearson's chi-square (𝛘2) test was used as appropriate. A regression analysis was performed to investigate the impact of wearing a thyroid collar for personnel protection during patient radiation exposure. The types of installed radiographic equipment included panoramic radiography (96.1%), cephalometric radiography (76.9%), intraoral radiography (72.9%), and cone-beam computed tomography (69.5%). Significant differences were observed in the learning pathway for the DRL (Fisher's exact test, p < 0.05), satisfaction with radiation safety education (Pearson's 𝛘2 test = 5.3975, Pr = 0.02), and use of personnel radiation monitoring systems (Pearson's 𝛘2 test = 18.1233, Pr = 0.000) between the groups. Significant differences were also observed in personnel protection using a thyroid collar and patient protection during panoramic radiography (odds ratio = 14.2). Dental hygienists with more than 10 years of experience were more satisfied with radiation safety education and more interested in radiation monitoring. Considering career experience, customized, continuous, and effective radiation safety management education should be provided.

Dental Radiography for Age Estimation: A Scoping Review

  • Jeon, Kug Jin;Kim, Young Hyun;Lee, Joo-Young;Jung, Hoi In;Han, Sang-Sun
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.31-50
    • /
    • 2022
  • Purpose: This study was to investigate the types of imaging modalities, analytical methods for age estimation, and the age of the subjects in research on age estimation using dental radiography through a scoping review, and to investigate the overall trends in age estimation studies. Materials and Methods: A scoping review was designed according to the Arksey and O'Malley guidelines and the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Three electronic databases were used as search sources (Medline, Embase, and Cochrane Library). Studies were classified according to the three main components of the research question. "What are the imaging modalities, analytical methods, and target age in dental imaging-based age estimation studies?" Result: The final 198 studies were selected by two reviewers. The most common imaging modality used in studies was panoramic radiography (69.7%), and studies using cone-beam computed tomography have increased over time. Analytical methods for age estimation were 62.6% in studies based on tooth development and 26.3% in studies using pulp/tooth ratio. The subject age was 27.8% for children and 27.3% for adults. Studies conducted in all age groups comprised the smallest category (5.2%). Conclusion: Panoramic radiography has been the most used types of imaging modalities for age estimation, and the most common analytical method was analysis of tooth development. Most studies targeted specific ages, and very few involved all age groups. Dental age estimation studies should be carried out with appropriate consideration of the imaging modality that is analyzed, the methods that are used, and the age that is targeted.

치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구 (A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry)

  • 박일우;정원교;황형석;임성환;이대남;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.17-24
    • /
    • 2013
  • 본 연구는 파노라마 표준 촬영에서 환자의 피폭 선량을 측정하여 방사선 생물학적 위험인자를 평가하고 환자의 피폭 선량 저감화 방안을 제시하고자 하였다. 피폭 선량의 측정 오차를 최소화하기 위하여 각 OSL 선량계의 교정상수를 구하였으며 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체와 갑상선, 직접적으로 포함되는 상 하 입술, 하악골 첨부, 촬영 중심점을 대상으로 ICRP에서 권고하는 인체 모형 표준 팬텀을 이용하여 측정하였다. 측정 결과, 촬영 중심점의 선량이 $413.67{\pm}6.53{\mu}Gy$로 최대였으며 상 하 입술의 경우 각각 $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$이었다. 또한 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체의 등가선량은 각각 $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$이었으며 하악골 첨부 및 갑상선의 등가선량은 $276.73{\pm}14.43{\mu}Gy$, $162.07{\pm}4.13{\mu}Gy$이었다. 결론적으로 측정된 피폭 선량은 방사선 생물학적 효과를 유발할 수 있었으며 치과 의료기관의 파노라마 표준 촬영에서 환자의 피폭 선량에 대한 저감화 방안으로 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침(regulation)이 필요하다. 이에 파노라마 검사에 의한 피폭 선량은 기술적 경제적 측면뿐 만 아니라 사회적 인자를 고려하여 합리적으로 용인 가능한 수준까지 최소화하기 위한 체계화된 프로토콜의 제정과 주변 결정 장기를 방어하기 위한 방사선 보호 기구에 대한 추가적 연구가 필요할 것으로 판단되었다.

파노라마를 이용한 하악과두에 인위적으로 형성한 골증식체의 평가 (EVALUATION OF ARTIFICIAL OSTEOPHYTE II\i l\iiANDIBUlAR CONDYLES USlhlG PANORAMIC RADIOGRAPHY)

  • 박명희;최순철
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.77-84
    • /
    • 1992
  • 저자는 파노라마 방사선사진을 이용하여 악관절 진단시에 진단학적 유용성을 알아보기 위하여 5개의 건조 두개골을 대상으로 하악과두의 4부위에 자각 인위적으로 형성한 골편을 부착시켜 피사체를 통상적인 위치, 전방으로 25㎜ 이동시킨 위치 및 전후 반대방향으로 위치시킨 상태에서 촬영하여 그 상을 비교하여 다음과 같은 결론을 얻었다. 피사체가 통상적인 위치에 있을 경우에는 골증식체가 전외부와 전중부에 있을 때 전내부와 상방부에 있을 때보다 관찰이 용이하였다 (p<0.01). 피사체가 25㎜ 전방이동한 경우에는 골증식체가 전중부와 전내부에 있을 때 전외부와 상방부에 있을 때보다 관찰이 용이하였다. (p<0.05). 피사체가 반대방향으로 위치한 경우에는 골증식체가 전중부에 있을 때 타부위에서보다 관찰이 용이 하였다 (p<0.05)

  • PDF