• Title/Summary/Keyword: Panel System

Search Result 2,177, Processing Time 0.026 seconds

Tracking System for Optimum Solar Power System of Widely Separated Cave (고립원격지 동굴 전원용 태양광발전 광 추적 시스템)

  • Suh, Oh-Ji;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.89
    • /
    • pp.27-33
    • /
    • 2008
  • Solar energy is most green and clean, unlimited and sustainable energy source on the earth. It is almost 97% of imported consumer energy in Korea. Because of resource poor nation, it is necessary to do their best to make alternative energy to allot their deficiency of the matter in hand of energy resources of petroleum. In a point of view of this problems, the natural solar energy should be improved by any methods as much, possible as we need. Photovoltaic generation with solar tracking system for obtaining optimal power is one of most benefit equipment to improve power of solar-cell panel producing clean electric power efficiently. Solar tracker is a device for orienting a solar photovoltaic panel toward the sun perpendicularly to sunlight, especially in widely separated place. For this reason, we are very interested in developing the equipment system of tracker, specially in solar cell applications, obtaining a high degree of accuracy to ensure that the optimal sunlight could be directed precisely against to the powered device. As a result, it was obtained of 12.46 volts at 90$^\circ$toward solar panel and 9.44 volts at 45$^\circ$, furthermore, improved efficiency more than 30% of average output voltage between tracker system (12.41V) and fixed system (8.55V), respectively. It is also very useful for optimum power system of widely separated cave.

Monitoring System with PLC I/O for Car Parking Lot (Car Parking Lot 모니터링 시스템)

  • Lee, Seong-Jae;Kim, Jae-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.511-512
    • /
    • 2007
  • The monitoring system has won acceptance as a premium mark that identifies the highest standard of product quality in advanced industry. The TOP features with multi-I/O ports and VGA & RCA TV-out ports supporting mirroring & multiple dual-display modes by windows 0/5. With the choice of versatile stands, panel mount, or VESA wall-mount swing arm and connecting to modem. Wireless keyboard, Customer Display and Card Reader, is your idea Panel system for the application of TOP(Touch Operation Pannel), KIOSK, or Office / Factory Automation. TOP is the hardware and software product that transacts all kind of functions for advanced technology equipment to button, switch, voice and graph etc so that let consumer use easily Industrial HMI System Touch Panel. System characteristics: Easy of use and flexibility to the user, Present a high value solution and advanced function for many Application, Factory Automation, Office Automation, Building Automation System, Information Service System, etc. Analog Touch - 2MB Flash Memory for Saving Screen Data - RS-232C/422 Serial Port - Multi Language Support.

  • PDF

The Performance Assessment Study of Solar Energy Cogeneration panel for Building Integrated System (건물통합을 위한 태양에너지 cogeneration panel 특성 분석 연구)

  • Kim, Yong-Hwan;Kang, Eun-Chul;Hyun, Myung-Taek;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.35-42
    • /
    • 2006
  • Solar Thermal-Electric Integrated system can be used to generate heat and electricity simultaneously and can improve indoor all qualify. So, it can save heating and electricity cost as it operates at relatively lower temperatures. In this study, one pv module was fixed on a normal wall and a pv module was mounted on a solarwall. And a ventilation fan in the solar energy cogeneration panel was operated from 12:00 to 17:00 hours. Experimental results are recorded and anaysized. The comparison of results show that the temperature of PV on solar energy cogeneration panel was decreased by $7{\sim}9^{\circ}C$ and the electrical output was improved by $2{\sim}3W$ compared with a PV system without solarwall.

Optimum Design of 3-Dimensional Panel Surface Grinder System (3차원 표면 연마기 시스템의 최적설계)

  • 이수훈
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.2
    • /
    • pp.52-58
    • /
    • 2000
  • the quality of a TV is closely connected with the high quality surface of Braun tube. To get high quality surface an improved grinding system is needed. It has three main parts : the housing part of supporting frame the outershaft part rotat-ed by motor and the innershaft part having eccentricity from the rotation axis of the outershaft. the housing part and the outershaft part are connected by outerbearings, The outershaft part and the innershaft part are connected by innerbearings. Although the outershaft part is rotated at high-speed the innershaft part is not rotated by offset coupling. The high quality grinding surface can be obtained by this mechanism of panel surface grinder, Because the innershaft is unbalanced by eccentricity from rotation axis of outershaft the unbalancing vibration is resulted In this rotor system with high-speed rota-tion the unbalancing vibration makes the opertion unstable. In this research the transfer function is obtained bythe frequency response analysis of finite element model. The simu-lation result is proved by comparing with the experimental result measured by signal analyzer Then the results are corre-lated. in order to improve the design an optimization method is used instead of two-planes balancing method The parts of the 3-dimensional panel surface grinder satisfy the each constraint, The result shows that the design of the panel surface grinder can be optimized.

  • PDF

Performance Analysis of POD-Type Waterjet System by Panel Method (패널법을 이용한 POD형 워터제트 추진장치의 성능해석)

  • Kim, Hyun-Yul;Kim, Moon-Chan;Chun, Ho-Hwan;Jung, Seok-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.5
    • /
    • pp.14-20
    • /
    • 2004
  • The aim of this paper is to analyze the steady performance of POD-type waterjet system by panel method. A surface panel method is applied to the present analysis. To analyze the compound propulsor. analysis program has been developed based on a perturbation potential method. The developed code has been validated by comparing the experimental data of shrouded propeller. The validated code has been applied to the POD-type waterjet system which can be used for the propulsion of amphibious vehicle. The computed results have been compared with experimental results. which shows a good agreement between them.

Seismic Performance Evaluation of Externally Reinforced Panel Water Tank Using Shaking Table Tests (진동대 실험을 통한 외부보강형 판넬조립식 물탱크의 내진성능평가)

  • Park, Se-Jun;Won, Seong-Hwan;Choi, Moon-Seock;Kim, Sang-Hyo;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.151-157
    • /
    • 2013
  • In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.

Monolithic Ambient-Light Sensor System on a Display Panel for Low Power Mobile Display (저 전력 휴대용 디스플레이를 위한 패널 일체형 광 센서 시스템)

  • Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.48-55
    • /
    • 2016
  • Ambient-light sensor system, which changes the brightness of a display as ambient light change, was studied to reduce the power consumption of the mobile applications such as note PC, tablet PC and smart phone. The ambient-light sensor system should be integrated on a display panel to improve the complexity and cost of mobile applications, so the ambient-light sensor and readout circuit was integrated on a display panel using low-temperature poly-silicon thin film transistors (LTPS-TFT). We proposed the new compensation method to correct the panel-to-panel variation of the ambient-light sensors, without additional equipment. We designed and investigated the new readout circuit with the proposed compensation method and the analog-to-digital converter for the final digital output of ambient light. The readout circuit has very simple structure and control timing to be integrated with LTPS-TFT, and the input luminance ranges from 10 to 10,000 lux. The readout rate is 100 Hz, and maximum differential non-uniformity with 20 levels of the final output below 0.5 LSB.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

Design and Implementation of Driver Circuit for AC TFEL Flat Panel Display (AC TFEL 평판표시장치의 구동회로 설계 및 구현)

  • 오건창;김명식;권용무;오명환;김덕진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.10
    • /
    • pp.27-34
    • /
    • 1993
  • In this paper, a driver system is designed and implemented to achieve 4-level gray scale CH TFEL(Thin Film ElectroLuminescent) flat panel display. To implement the driver system, commercial EL driver IC chips are used to apply high voltage pulses to the EL panel and a high voltage switching circuit is designed for the EL driver IC. A new method of reducing storage delay time of transistor is proposed to obtain a reliable switching circuit. The controller for EL driver and switching circuit is also designed. The designed driving scheme applicable to EL display with 4-level gray scale is based on the linear characteristics of brightness vs. frequency of AC TFEL. By experiment, it has been shown that the brightness of AC TEFL display with the implemented driving system is controlled by the level of gray scale.

  • PDF