Applicability on Water Treatment Structure of Anti-corrosive Sheet Molding Compound Panel (고분자수지계 패널형 방수방식재의 수처리구조물 적용성에 관한 실험적연구)

  • Seo, Hyun Jae;Park, Jin Sang;Bae, Kee Sun;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.161-163
    • /
    • 2011
  • Due to various kind of waterproof materials and methods, which is difficult to select the most appropriate to waterworks. The materials used to prevent the deterioration of the service life is short, because of the chemical erosion. So, in the 2010 Office of Waterworks Seoul Metropolitan Government has set new standards. Recently, SMC panel is a trend that is being applied to water treatment facilities. However, SMC panel has not yet implemented a performance evaluation. Therefore, this study to confirm that satisfaction for the Office of Waterworks Seoul Metropolitan Government of the performance requirements, when the applied the SMC panel to water treatment structure.

  • PDF

Analysis of Inspection Ability of Panel Using BMPC Method

  • Shinji, Ohyama;Kim, Doh-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.158.6-158
    • /
    • 2001
  • A band function model paired comparison(BMPC) method is a kind of paired comparison methods. Considering that human has ambiguity, the BMPC method uses a monotonous increase function with the width as the human judgment characteristic. Since panel´s judgments do not always have enough response, it is very important to examine inspection abilities of each panel. In this study. We focus on the difference of band functions in each panel, which is the characteristic function of judgment in the BMPC method, and examine the method of obtaining panels inspection abilities. Three kinds of evaluation functions, "the dispersion of judgments", "the resolution", and "the difference of the judgments" are defined from Panel´s characteristic function of ...

  • PDF

A Study of Auto-body Panel Correction of Forming Analysis that Use Dynamic-extensive Finite Element Method (동적-외연적 유한요소법을 이용한 차체 판넬 성형해석에 관한 연구)

  • Jung Dong Won;Hwang Jae Sin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.115-126
    • /
    • 2004
  • In the present work a finite element formulation using dynamic-explicit time integration scheme is used for numerical analysis of auto-body panel stamping processes. The lumping scheme is employed for the diagonal mass matrix and dynamic explicit formulation. Analyzed auto-body panel stomping process correction of forming using software called Dynaform using dynamic extensive method. Further, the simulated results for the auto-body panel stamping processes are shown and discussed. Its application is being increased especially in the automotive industrial area for the cost reduction, weight saving, and improvement of strength.

Electric Current Accelerated Degradation Test Design for OLED TV (OLED TV Panel의 전류가속열화시험 설계)

  • You, Ji-Sun;Lee, Duek-Jung;Oh, Chang-Suk;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Purpose: The purpose of this study is to estimate the life time of OLED TV panel through electric current ADT(Accelerated Degradation Test). Methods: We performed accelerated degradation test for OLED TV Panel at the room temperature to avoid high temperature impact on the luminance. Results: we got more accurately the life time of the OLED TV when we applied ADT without temperature factor than including both current and temperature. Conclusion: Until now, the ADT of the OLED TV has been conducted with temperature and current at the same time for reducing test time and costs. We estimate incorrect life time when the temperature is adopted as an accelerated factor. Due to the high temperature impact on the luminance of the OLED TV panel. So as to solve this problem, we discard temperature and use electric current only.

Design of 1 panel LCD system without color filter For projection color television

  • Yeo, Sang-Ok;Kim, Young-Woon;Park, Myung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.969-971
    • /
    • 2002
  • In this paper, we study the performances of optical system design using the 1 panel LCD without color filter for projection color television. We analyze the optical efficiency compare this system with 1 panel LCD system using the color filter, and work out a constraint condition of 1 panel LCD without color filter for optical design. We design a high brightness 1 panel optical system using a complex reflection mirror and suggest a method of the optical system design.

  • PDF

Development of n Remote Monitoring System for TFT-LCD Panel Test Automation (TFT-LCD 채널검사 자동화를 위한 원격 모니터링 시스템 개발)

  • Park, Hyoung-Keun;Lee, Seung-Dae;Kim, Sun-Youb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.483-487
    • /
    • 2007
  • In this study, we develop a new remote monitoring system for TFT-LCD panel test automation. Having to realtime monitor of Ti-Con board, this system needs to discrimination whether breakdown or not that is able to transmit processing data for engineer at long distance place using TCP/IP. The result of the development, that can be fast opposition to the breakdown and the multiple processing

  • PDF

Optimal design of Natural Fiber Composite Structure for Automobile

  • Lee, Haseung;Kong, Changduk;Park, Hyunbum
    • International Journal of Aerospace System Engineering
    • /
    • v.3 no.1
    • /
    • pp.21-24
    • /
    • 2016
  • In this study, a optimal design on the hood automotive using eco-friendly natural fiber composites is performed. The hood of an automobile is determined by dividing the Inner panel shape through optimization phase to outer panel and inner panel. It was performed to optimize the size of the thickness of the inner panel and the outer panel by applying a flax/epoxy composite materials. The optimized shape was evaluated for weight-lightening, stability and the pedestrian collision safety. Through the resin flow analysis are confirmed to molding possibility judgment of product.

Elasto-Plastic Analysis on Connections of Precast Large Panel Structures (프리캐스트 대헝판 구조물의 접합부에 관한 탄소성해석)

  • 권택진;박강근;권익노;조강표
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.27-34
    • /
    • 1993
  • Precast large panel structures behave differently form frame and monolithic wall structures under external loads, because of the distinct planes of weakness in the horizontal and vertical joints between panels. These joints may slide and open during shaking, producing large localized changes in the bending and shear stiffness of individual walls. The structural behavior of large precast panel buildings depends on the relative strength and stiffness of the panels and joints. Special modeling are thus required for the analysis of precast panel connections. This study suggests a new analytical modeling and method to obtain the rational estimation of discontinuity and slip movements form the connections of precast large panel structures .

  • PDF

A Study on the Application of Fixed-concentrated PV Module Hybrid Panel for BIPV (고정식 집속형 PV모듈 복합패널의 BIPV적용성 검토)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.77-83
    • /
    • 2005
  • The verified thermal efficiency, thermal capacity confirmed the effects of the cooling system. Therefore, it is useful for preventing the PV cell temperature rising when solar radiation accumulates in summer. When adopting a hybrid panel for the BIPV system, the affected areas include the vertical outside walls facing the south, southeast, and southwest on the curtain walls excluding windows. The standards on replace aluminum panel which were the popular exterior material were investigated, Designing practice made sure that it could be manufactured in various sizes, and confirmed the most proper method to install a hybrid panel in the BIPV system.

A Study on High Efficient Energy Recovery Circuit for AC Plasma Display Panel Drive (AC Plasma Display Panel구동 장치의 고효율 전력 회수 회로에 관한 연구)

  • Yoon Won-Sik;Kang Feel-Soon;Park Han-Woog;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.442-445
    • /
    • 2001
  • The sustaining driver for color ac plasma display panel should provide alternating high voltage pulses and recover the energy discharged from the intrinsic capacitance between the scanning and sustaining electrodes inside the panel. In this paper, a novel efficient energy recovery circuit employing boost-up function is proposed to achieve a faster rise-time and in order to obtain a stable sustain voltage. The principle of operation, features, and simulated results are illustrated and verified on an equivalent capacitance, which is equals In that of 40-inch-panel, 200 (kHz).

  • PDF