• Title/Summary/Keyword: Panel Details

Search Result 79, Processing Time 0.03 seconds

Characteristics of FRP-Concrete Composite Decks under Negative Flexure (FRP-콘크리트 합성 바닥판의 부모멘트부 거동 특성)

  • Kim, Sung-Tae;Cho, Keun-Hee;Park, Sung-Yong;Cho, Jeong-Rae;Kim, Byung-Suk;Shin, Yung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.86-89
    • /
    • 2006
  • The flexural performance of FRP-concrete composite deck in the connection between decks is evaluated. FRP-concrete composite deck, an innovative system is composed of concrete in the top and FRP panel in the bottom. The experiments are carried out on specimens with different details, such as FRP module and reinforcement of FRP re-bars. As a result, we verify that the transverse connections between our FRP-concrete composite decks with presented details secure enough safety and serviceability.

  • PDF

Behavior of Joint Panel of Precast Prestressed Concrete Pavement System with Different Design Details

  • Ugur, Izzet;Shim, Hyun-Bo;Nam, Sang-Hyeok;Song, Ha-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.575-576
    • /
    • 2009
  • From the extensive review of literature on existing precast prestressed concrete pavement (PPCP) systems, an innovative PPCP system has been developed. After the analysis and design, the sample system has been built and experimented under service loads and the defects of the system has been noted. Further study has been done to improve the performance of the defects. The appeared cracks around post-tensioning pockets was a crucial problem which needed to be solved in order to satisfy the service life of the system without any doubt. In this paper, different shape and arrangement of the post-tensioning pockets in the joint panel has been designed and analysed in order to find best performance for the system.

  • PDF

Nonlinear Finite Element Analysis for the Precast Concrete Large Panel Subassemblage subjected to Horizontal Force (수평하중을 받는 프리캐스트 콘크리트 대형 판넬 부분구조의 비선형 해석)

  • 박병순;서수연;이원호;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.157-162
    • /
    • 1993
  • During earthquakes, the joints provide a principal means for energy dissipation, and these are also responsible for introducing a nonlinear behavior to the overall building system, while large panels remain in the elastic range. In analysis for the precast concrete large panel system, it is difficult to make a general analysis for their behavior because of differences in joint details. Therefore, in case of presence of vertical joints, it is more difficult because of the interaction between the horizontal joints and vertical joints, In this study, a nonlinear finite element analysis is performed using the gap element, friction element, and concrete material model, and the results are compared with the experimental results.

  • PDF

Upgrading flexural performance of prefabricated sandwich panels under vertical loading

  • Kabir, M.Z.;Rezaifar, O.;Rahbar, M.R.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.3
    • /
    • pp.277-295
    • /
    • 2007
  • 3-D wall panels are used in construction of exterior and interior bearing and non-load bearing walls and floors of building of all types of construction. Fast construction, thermal insulation, reduced labor expense and weight saving are the most well pronounced advantage of such precast system. When the structural performance is concerned, the main disadvantage of 3D panel, when used as floor slab, is their brittleness in flexure. The current study focuses on upgrading ductility and load carrying capacity of 3D slabs in two different ways; using additional tension reinforcement, and inserting a longitudinal concentrated beam. The research is carried on both experimentally and numerically. The structural performance in terms of load carrying capacity and flexural ductility are discussed in details. The obtained results could give better understanding and design consideration of such prefabricated system.

Effects of pulse-like nature of forward directivity ground motions on the seismic behavior of steel moment frames

  • Mansouri, Iman;Shahbazi, Shahrokh;Hu, Jong Wan;Moghaddam, Salar Arian
    • Earthquakes and Structures
    • /
    • v.17 no.1
    • /
    • pp.1-15
    • /
    • 2019
  • In the structures with high level of ductility, the earthquake energy dissipation in structural components is an important factor that describes their seismic behavior. Since the connection details play a major role in the ductile behavior of structure, in this paper, the seismic response of 3-, 5- and 8-story steel special moment frames (SMFs) is investigated by considering the effects of panel zone modeling and the influence of forward-directivity near-field ground motions. To provide a reasonable comparison, selected records of both near and far-field are used in the nonlinear time-history analysis of models. The results of the comparison of the median maximum inter-story drift under excitation by near-field (NF) records and the far-field (FF) ground motions show that the inter-story drift demands can be obtained 3.47, 4.86 and 5.92 times in 3-, 5- and 8-story structures, respectively, undergoing near-field earthquakes.

An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions (보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구)

  • 박병윤
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1991.09a
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF

Pressure equalization of rainscreen facades: Analysis of the field data in the frequency domain

  • Kumar, K. Suresh;Wisse, J.A.
    • Wind and Structures
    • /
    • v.4 no.2
    • /
    • pp.101-118
    • /
    • 2001
  • This paper reports the field measurements concerning pressure equalization of rainscreen facades carried out at the Technical University of Eindhoven (TUE) in the Netherlands. The field facility including the details of test panel, meteorological tower, instrumentation, data collection and analysis is presented. Results of investigations into cavity response for various leakage and venting configurations are discussed. Frequency domain techniques have been utilized to show the influence of wind as well as facade characteristics on the pressure equalization performance. Further, this paper presents an early attempt to synthesize the experimental results into existing building codes.

A study on the design and construction of operating room (병원 수술실 설계 및 시공에 관한 연구)

  • Jung, Eul-Kyu;Oh, Jung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

Seismic Behavior of Steel Moment Connections with a Slab and Different Structural Characteristics (슬래브와 구조특성을 고려한 철골 모멘트 접합부의 지진거동)

  • 조창빈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.200-207
    • /
    • 2003
  • The seismic behaviors of steel moment connections are investigated based on the numerical analysis of the connections with US and Japanese typical details. The rupture index, representing the fracture potential, is used to evaluate the ductility of the connections at the critical location. The results show that the presence of a slab increases the beam strength, imposes constraint near the beam top flange, and consequently, induces concentrated deformation near the beam access hall, which reduces the ductility of the connection. The total deformation capacity of the connection depends not only on a beam but also on a column and panel zone.

  • PDF

Vibration analysis of spherical sandwich panels with MR fluids core and magneto-electro-elastic face sheets resting on orthotropic viscoelastic foundation

  • Kargar, Javad;Arani, Ali Ghorbanpour;Arshid, Ehsan;Rahaghi, Mohsen Irani
    • Structural Engineering and Mechanics
    • /
    • v.78 no.5
    • /
    • pp.557-572
    • /
    • 2021
  • The current study considers free vibration of the spherical panel with magnetorheological (MR) fluids core and magneto-electro-elastic face sheets. The panel is subjected to electro-magnetic loads and also is located on an orthotropic visco-Pasternak elastic foundation. To describe the displacement components of the structure, the first-order shear deformation theory (FSDT) is used and the motion equations are extracted by employing Hamilton's principle. To solve the motion differential equations, Navier's method is selected as an exact analytical solution for simply supported boundary conditions. Effect of the most important parameters such as magnetic field intensity, loss factor, multi-physical loads, types of an elastic medium, geometrical properties of the panel, and also different material types for the face sheets on the results is considered and discussed in details. The outcomes of the present work may be used to design more efficient smart structures such as sensors and actuators.