• 제목/요약/키워드: Palladium membrane

검색결과 37건 처리시간 0.021초

Stable isotope and water quality analysis of coal bed methane produced water in the southern Qinshui Basin, China

  • Pan, Jienan;Zhang, Xiaomin;Ju, Yiwen;Zhao, Yanqing;Bai, Heling
    • Membrane and Water Treatment
    • /
    • 제4권4호
    • /
    • pp.265-275
    • /
    • 2013
  • China is one of the countries with the highest reserves of coal bed methane (CBM) in the world. Likewise, the CBM industry is significantly growing in China. However, activities related to CBM development have led to more environmental problems, which include serious environmental damage and pollution caused by CBM-produced water. In this paper, the detailed characteristics of CBM-produced water in the southern Qinshui Basin were investigated and analyzed and compared with local surface water and coal mine drainage. Most of CBM-produced water samples are contaminated by higher concentration of total dissolved solids (TDS), K (Potassium), Na (Sodium) and $NH_4$. The alkalinity of the water from coalmines and CBM production was higher than that of the local surface water. The concentrations of some trace elements such as P (Phosphorus), Ti (Titanium), V (Vanadium), Cr (Chromium), Ni (Nickel), Zn (Zinc), Ge (Germanium), As (Arsenic), Rb (Rubidium), and Pd (Palladium) in water from the coalmines and CBM production are higher than the acceptable standard limits. The ${\delta}D$ and ${\delta}^{18}O$ values of the CBM-produced water are lower than those of the surface water. Similarly, the ${\delta}D$ values of the CBM-produced water decreased with increasing drainage time.

Cu Reflow를 이용한 Pd-Cu-Ni 합금 수소분리막 특성 (Characteristic of Pd-Cu-Ni Alloy Hydrogen Membrane using the Cu Reflow)

  • 김동원;김흥구;엄기연;김상호;이인선;박종수;이신근
    • Korean Chemical Engineering Research
    • /
    • 제44권2호
    • /
    • pp.160-165
    • /
    • 2006
  • 니켈 분말을 이용하여 제조된 다공성 니켈 지지체 위에 팔라듐-구리-니켈 합금 수소 분리막을 제조하였다. 다공성 니켈 지지체는 열적안정성과 수소취성에 강한 모습을 나타내었으며, 다공성 니켈 지지체에 기존의 습식 방식인 염산에 의한 표면 전처리 방식을 건식 방식인 플라즈마 표면개질로 대체하였다. 다공성 니켈 지지체의 기공을 매립하기 위해 전해도금방식으로 $2{\mu}m$의 두께로 코팅하였으며, 그 후 니켈 도금된 지지체 위에 스퍼터 방식으로 팔라듐을 $4{\mu}m$, 구리를 $0.5{\mu}m$의 두께로 코팅하였다. 이와 같이 제조된 시편을 $700^{\circ}C$에서 1시간 구리 리플로우를 통해 미세기공이 없는 매우 치밀한 팔라듐-구리-니켈 합금 분리막을 제조하였다. 그 결과 팔라듐-구리-니켈 합금 수소분리막은 다공성 니켈지지체와 좋은 접착성을 가지고 있으며 수소-질소 혼합가스에서 무한대의 분리도 값을 나타내었다.

Vacuum electrodeposition에 의한 팔라듐 합금 금속막 제조 및 수소 분리에 관한 연구 (Fabrication of a palladium alloy composite membrane by vacuum electrodeposition)

  • 남승은;이규호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.96-98
    • /
    • 1998
  • 1. 서론 : 팔라듐이나 이의 합금막들은 높은 선택적 투과특성으로 인해 수소 정제나 분리막 반응기와 같은 산업응용 분야에서 매우 높은 관심을 갖고 있다. 상업적으로 이용되고 있는 이러한 막들은 통상적인 metallugical process에 의해 제조괸 self-supported type으로 수소 투과 속도가 낮을 뿐만 아니라 팔라듐 등은 고가의 귀금속이므로 비경제적이다. 따라서 현재 대부분의 연구자들은 기계적 강도를 유지하기 의한 다공성 지지체 위에 얇은 금속 박막을 코팅함으로서 투과성을 높이는 동시에 경제적인 복합막 형태의 막을 만드는데 연구의 촛점을 맞추고 있다. 이러한 형태의 막을 제조하기 위한 금속 박막 제조법은 무전해 도금법(electroless deposition), 화학증착법(CVD), 스퍼터링(sputtering), 전해도금법(electrodeposition) 등이 시도되었다. 그러나 수소에 대한 우수한 선택적 투과 특성을 갖기 의해서는 대부분 5$\mu$m 이상의 두꺼운 막을 제조하였으며 이보다 얇은 막의 제조에 한계가 있기 때문에 이들 막에 대한 기체 투과 특성에 대한 연구결과는 많지 않다. 본 연구에서는 기존의 전기도금법을 응용한 소위 'vacuum electrodeposition' 이란 새로운 기술을 도입함으로써 우수한 선택적 투과성을 갖는 2$\mu$m 이하의 팔라듐 합금 박막 제조를 가능하게 하였다. 지지체 표면의 거칠음 정도, 평균 기공 크기 등의 지지체 성질의 조절에 의한 금속 박막의 핀홀을 최소화함으로써 질소와 같은 inert gas의 투과도는 거의 없게 유지하는 동시에 금속 박막 두께, 결정 구조(e.g. grain size), 합금 조성 등을 조절함으로써 수소의 투과도를 높이고자 하였다. 있다. 후자의 경우, 미량의 과산화수소수 (1~10,000 ppm)를 이용해 처리 해주는 방법의 경우 경제적으로 큰 장점이 있고, 처리가 단순하다는 장점이 있으나 과산화수소수 자체에 포함하고 있는 높은 impurit level, 그리고 처리후 장시간의 flushing time을 가져야 한다는 단점등이 존재 하고 있다.요구된다. 몰입이 가능하여 임계치가 저하된 것으로 여겨진다. 또한 광학적 이득의 존재는 이 구조에 의한 극단파장 반도체 레이저다이오드의 실현 가능성을 나타내는 것이다.548 mL에 비해 통계학적으로 의의 있게 적었다(p<0.05). 결론: 관상동맥우회로 조성수술에서 전방온혈심정지액을 사용할 때 희석되지 많은 고농도 포타슘은 fliud overload와 수혈을 피하고 delivery kit를 사용하지 않음으로써 효과적이고 만족할 만한 심근보호 효과를 보였다.를 보였다.4주까지에서는 비교적 폐포는 정상적 구조를 유지하면서 부분적으로 소폐동맥 중막의 비후와 간질에 호산구 침윤의 소견이 특징적으로 관찰되었다. 결론: 분리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술

  • PDF

이트륨 함량에 따른 Pd-Ir-Y 3원계 합금 촉매 입자의 특성과 산소 환원 반응의 활성 비교 (Comparison of the Characteristics of Pd-Ir-Y Ternary Alloy Catalyst Particles and Oxygen Reduction Activity According to Yttrium Contents)

  • 김도형;이은애;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제29권3호
    • /
    • pp.260-266
    • /
    • 2018
  • To enhance catalyst activity of the palladium (Pd) towards oxygen reduction reaction (ORR), iridium (Ir) and yttrium (Y) were alloyed by polyol method. Due to the low reduction potential of Y, it is hard to reduce Y ion completely by polyol method. In XPS spectra, the binding energy of the Pd is shifted to a lower value, which indicates the d-electron of Pd is filled by the electron from the Y. And other phases of Y are observed by the XPS. Among the catalysts, the $Pd_4IrY_{0.1}/C$ showed the best activity towards ORR, which indicates the metallic Y is effective for improving the catalytic activity. Thus, for further enhancing ORR activity, the novel method for complete reduction of Y is needed.

구강점막질환환자에서 치과재료를 이용한 첩포시험 결과에 대한 고찰 (Dental materials in patients with oral mucosal disease based on the results of patch test study)

  • 정성희;김지수;김경희;옥수민;허준영;안용우
    • 대한치과의사협회지
    • /
    • 제52권2호
    • /
    • pp.96-104
    • /
    • 2014
  • The aim of this study was to investigate the frequency of positive patch test reaction to dental materials in patients with oral mucosal diseases. Epicutaneous patch test was performed in 110 patients with oral mucosal diseases; 41 patients with oral lichen planus(OLP), 44 patients with burning mouth syndrome(BMS), 25 patients with other oral mucosal diseases including recurrent aphthous ulcer and mucous membrane pemphigoid. The obtained results were as follows: Oral gold restorations were most common in patents with oral mucosal diseases and porcelain fused metal crown, implant appeared in the order. 33 of 110 patients did not appear skin reactions (negative, 30%) and 77 patients (positive, 70%) had skin reactions including redness, rash, blisters. Dental materials causing positive reaction to patch test were mainly as gold-sodium-thiosulfate (26.7%), nickel sulfate(Ni) (22.7%), cobalt chloride(Co) (14.7%), palladium chloride(Pd) (11.9%), potassium dichromate (10.7%) in order, respectively. In conclusion, old metal restorations could be the cause of oral mucosal diseases and epicutaneous patch test could be used as a tool to improve the oral conditions.

직접 개미산 연료전지용 연료극 촉매의 특성 연구 (Characterization of Alternative Anode Catalysts for Direct Formic Acid Fuel Cell)

  • 유재근;이효송;김기호;김영천;한종희;오인환;이영우
    • Korean Chemical Engineering Research
    • /
    • 제44권3호
    • /
    • pp.314-318
    • /
    • 2006
  • 본 연구에서는 고분자 전해질 연료전지(PEMFC)의 연료로 새롭게 제안된 개미산을 이용한 직접 개미산 연료전지 시스템에서 우수한 성능을 구현하기 위해서 촉매를 개발하고, EDS와 SEM을 사용하여 촉매의 특성을 분석하였다. 또한, 단일전지 실험을 통하여 기존 상용 촉매와 성능을 비교하였다. 본 연구에서 개발된 Pt-Pd 촉매는 SEM 분석 결과 입자의 크기가 균일하고 조밀한 분포를 나타내었다. 촉매의 종류에 따른 연료전지의 성능실험에서 Pd의 함량 비율이 높을수록 전지의 성능이 우수하였으며, 특히 Pd black은 산화가스로 산소를 사용하였을 경우 상온에서 $130mW/cm^2$ 의 최대전력밀도를 나타냈다. 또한, Pt-Pd 촉매도 우수한 성능을 보였으며, 특히 Pt와 Pd의 비율이 1:1일 때 산화가스로 산소를 사용하였을 경우 상온에서 $120mW/cm^2$의 최대전력밀도를 나타냈다. 시스템의 운전온도를 $60^{\circ}C$까지 증가 시켰을 때, 전지의 성능은 촉매의 반응활성 증가로 크게 증가하였으나, 막의 최고 활성 영역인 $50{\sim}60^{\circ}C$ 범위에서는 운전온도가 전지의 성능에 큰 영향을 미치지 않았다.

금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량 (Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension)

  • 한철우;인교;최종문;김선태;김영상
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.608-615
    • /
    • 2000
  • 물 시료에 존재하는 극 미량의 니켈과 코발트를 착물로 형성시켜 이온 교환수지 서스펜션에 흡착시켜 분리 농축하여 정량하는 방법을 연구하였다. 리간드로 APDC (ammonium pyrrolidine dithiocarbamnate)를 사용하여 극 미량 이온들을 착물로 형성시켜 농축한 다음, 전열 원자흡수 분광광도법으로 정량하였다. 이때 착물 형성을 위한 수용액의 pH와 착화제인 APDC의 양, 흡착을 위한 이온교환 수지의 종류 및 저어주는 시간, 역 분산에 사용하는 산의 종류 및 농도, 초음파 진동시간 등의 실험조건들을 최적화 하였다. 시료용액의 pH를 5로 조절하고 APDC의 양을 몰 비로 분석원소 전체의 430배 이상 첨가하여 코발트와 니켈을 정량적으로 착물을 형성시켰다. 이온교환 수지는 음이온 형태의 Dowex 2-X8이 우수하였다. pH를 조절한 시료용액, 리간드 및 수지 서스펜션을 혼합하고 1분간 저어주어 흡착을 완전하게 하였다. 역 분산을 위해서는 0.1 M 염산이 가장 좋았고, 이때 막 필터로 거른 교환 수지를 초음파 진동기에서 7분간 진동하면 충분하였다. 팔라듐을 염산과 함께 사용하면 매트릭스를 개선하여 재현성과 감도가 개선되었다. 바탕흡수 신호표준편차의 세배에 해당하는 검출한계는 Co 0.36 ng/mL, Ni 0.27 ng/mL로 극미량 검출이 가능하였고 시료에 일정량 첨가한 분석원소의 회수율은 각각 99-102%와 100-105% 이었다.

  • PDF