• Title/Summary/Keyword: Paldang reservoir

Search Result 77, Processing Time 0.033 seconds

Trend of Some Hydrologic Features in the Five Great River Systems in Korea (5대강(大江) 수계유역(水系流域) 수문량(水文量) 변동추이(變動推移))

  • Shon, Dong-Sup;Suh, Seung-Duk
    • Current Research on Agriculture and Life Sciences
    • /
    • v.17
    • /
    • pp.31-38
    • /
    • 1999
  • Trend of some hydrologic features such as precipitation, runoff and reservoir storage rates in the five great river systems of Han, Nakdong, Keum, Yeongsan and Seomjin river watershed areas were surveyed and analysed. The sample period of Sept. 1994 to Aug. 1998 (four years) was chracterized by unusual climatic features such as El Nino, La Nina and areal terrible storms. And also average values of rainfall and runoff of the priod of 1961 to 1990 (30 years) were surveyed and analysed compared with the sample preiod events for the same river systems. In case of the monthly mean rainfall of the sample period (Sept. 1994 to Aug. 1998 : 48 months) in the five great river systems, 20 months, 19 months, 20 months, 21 months and 18 months in the Han, Nakdong, Keum, Yeongsan and Seomjin river system respectively were higher than monthly average rainfall records of the 30 year records. For the monthly runoff in the same river systems, 7 months, 9 months, 7 months, 11 months and 11 month in the Han, Nakdong, Keum, Yeongsan and Seomjin river systems respectively were higher than the monthly average runoff of the period of 30 years. For the storage rates, most of the dams in the Han river systems were highly stored through the year continuously and Paldang dam was specially higher than the other dams in the same river system. And most of the dams in the other river systems were stored irregularly but getting much better than early time during the 48 months. And special climatic features were not found during the sample period of 48 months, Sept. 1994 to Aug. 1998.

  • PDF

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

Runoff Characteristics of Non-Point Source according to Cultivation Activity in River District (하천구역 내 경작활동으로 인한 비점오염물질 유출특성)

  • Ahn, Jae Hwan;Yun, Sang Leen;Kim, Seog Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.480-487
    • /
    • 2012
  • The field study was carried out to investigate runoff characteristics of non-point source (NPS) by cultivation activity in river district. Two sites were selected mainly as G region (paddy field, green house), located in Kwangju, Gyeonggi Province, and S region (ordinary field), located in Namyangju, Gyeonggi Province, those belong to Paldang reservoir watershed. The paddy field with water storage capacity showed a slow increase in runoff as rainfall intensity increases. Meanwhile, both green house and ordinary filed revealed a rapid increase. The average BOD runoff concentration of paddy field, green house, and ordinary field was 2.0 mg/L, 2.8 mg/L, 7.9 mg/L, respectively. It indicates that ordinary field shows the highest value in BOD, SS, T-N, and T-P concentration due to the soil loss during rainfall. As a result of runoff load estimation according to the field, a T-N runoff load of paddy field was 1,793.9 kg/year, higher than that of ordinary field. It was estimated that a SS runoff load of ordinary field was 69,704 kg/year and accounts for more than 70% of overall runoff load.

Operation of CROM System and its Effects of on the Removal of Seston in a Eutrophic Reservoir Using a Native Freshwater Bivalve (Anodonta woodiana) in Korea. (담수산 이매패 펄조개를 이용한 흐름형 유기물 제어(CROM) 운영 - 퇴적물의 영향)

  • Kim, Baik-Ho;Baik, Soon-Ki;Hwang, Su-Ok;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.161-171
    • /
    • 2009
  • A 'continuous removal of organic matters (CROM) system' using a native freshwater bivalve in Korea Anodonta woordiana, was developed to determine its potential of controlling various sestons in eutrophic lake system, and to evaluate its effect on water quality improvement under consideration of sediment addition as habitat. We designed CROM experiments with four treatments: no mussels and no sediment (W, negative control), no mussels and sediment (WS, positive control), mussels and no sediment (WM), and mussels and sediment (WMS). The experiments were performed at the condition of 18${\sim}$25 L $h^{-1}$ of inflow, mussel density of 486.1 indiv. $m^{-2}$, and temperatures between 15 and $22^{\circ}C$ for 13 consecutive days. Physicochemical and biological parameters were measured at daily (10:00 am) intervals after the mussel addition. Results indicated that mussel stockings without addition of sediment effectively removed sestons (suspended solids and chlorophyll-a) at nearly same level over 80 percentage of the control during the study, while there were no differences in removal activities of sestons between with and without sediment (P>0.5). Therefore, it clearly suggests that CROM system using A. woordiana has a strong potential to control the seston in surface water of eutrophic lake.

The Calculation Method of Cell Count for the Bloom-forming (Green tide) Cyanobacterium using Correlation between Colony Area and Cell Number in Korea (군체 크기와 세포수 상관관계를 이용한 녹조 유발 남조류의 세포수 산정 방법)

  • You, Kyung-A;Song, Mi-Ae;Byeon, Myeong-Seop;Lee, Hae-Jin;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.4
    • /
    • pp.350-357
    • /
    • 2014
  • Harmful Algal Bloom Alert System (HABAS) for drinking water supply is require to fast and accurate count as system monitoring of cyanobacterium occurrence and inducing a response action. We measured correlation between colony size and cell number including genus Anabaena, Aphanizomenon, Microcystis, Oscillatoria which are targeted at HABAS, deducted from standard formula, and suggested calculation method from colony size to the number of cell. We collected cyanobacteria samples at Han River (Paldang reservoir), Nakdong River (Dalseong weir, Changnyeonghaman weir) and Geum River (Gobok reservoir) from August to October, 2013. Also, we studied correlation between colony size and cell number, and calculated regression equation. As a result of correlation of harmful cyanobacteria by genus, Anabaena spp. and Aphanizomenon spp. having trichome showed high correlation coefficients more than 0.93 and Microcystis spp. having colony showed correlation coefficient of 0.76. As a result of correlation of harmful cyanobacteria by species, Anabaena crassa, Aphanizomenon flos-aquae, A. issatschenkoi, Oscillatoria curviceps, O. mougeotii having trichome showed high correlation coefficients from 0.89 to 0.96, and Microcystis aeruginosa, M. wessenbergii, M. viridis having colony showed correlation coefficients from 0.76 to 0.88. Compared with other genus Microcystis relatively showed low correlation because even species and colony size are the same, cell density and cell size are different from Microcystis strains. In this study, using calculated regression might be fast and simple method of cell counting. From now on, we need to secure additional samples, and make a decision to study about other species.

Treatment of Contaminated Sediment for Water Quality Improvement of Small-scale Reservoir (소하천형 호수의 수질개선을 위한 퇴적저니 처리방안 연구)

  • 배우근;이창수;정진욱;최동호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.31-39
    • /
    • 2002
  • Pollutants from industry, mining, agriculture, and other sources have contaminated sediments in many surface water bodies. Sediment contamination poses a severe threat to human health and environment because many toxic contaminants that are barely detectable in the water column can accumulate in sediments at much higher levels. The purpose of this study was to make optimal treatment and disposal plan o( sediment for water quality improvement in small-scale resevoir based on an evaluation of degree of contamination. The degree of contamination were investigated for 23 samples of 9 site at different depth of sediment in small-scale J river. Results for analysis of contaminated sediments were observed that copper concentration of 4 samples were higher than the regulation of hazardous waste (3 mg/L) and that of all samples were exceeded soil pollution warning levels for agricultural areas. Lead and mercury concentration of all samples were detected below both regulations. Necessary of sediment dredge was evaluated for organic matter and nutrient through standard levels of Paldang lake and the lower Han river in Korea and Tokyo bay and Yokohama bay in Japan. The degree of contamination for organic matter and nutrient was not serious. Compared standard levels of Japan, America, and Canada for heavy metal, contaminated sediment was concluded as lowest effect level or limit of tolerance level because standard levels of America and Canada was established worst effect of benthic organisms. The optimal treatment method of sediment contained heavy metal was cement-based solidification/stabilization to prevent heavy metal leaching.

Continuous Removal of Organic Matters of Eutrophic Lake Using Freshwater Bivalves: Inter-specific and Intra-specific Differences (CROM를 이용한 부영양 저수지의 유기물 제어: 이매패의 종 특이성에 대하여)

  • Lee, Ju-Hwan;Hwang, Soon-Jin;Park, Sen-Gu;Hwang, Su-Ok;Yu, Chun-Man;Kim, Baik-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.350-363
    • /
    • 2009
  • Inter- and intra-specific differences in removal activities, filtering rates (FR) and production of feces-and pseudo-feces (PF) between a native freshwater bivalve in Korea, Anodonta woodiana Lea and Unio douglasiae Griffith et Pidgeon, were compared using a continuous removal of organic matters (CROM) system. The CROM system comprised five steps; input of polluted water, control of water flow, mussel treatment, analysis of water quality and discharge of clean water. The study was designed to compare the removal activity of organic matters between A. woodiana and U. douglasiae, and the intra-specific differences between density and length in A. woordiana. Results clearly indicate that two kinds of mussels had obvious removal activities of seston in the eutrophic reservoir. First, if both are similar in shell length, there were no significant inter-specific differences in removal activity between A. woordiana and U. douglasiae (P>0.5), but FRs of U. douglasiae was relatively high due to low ash-fee dry weight. Second, if both are same in animal density, the smaller mussels (1$\sim$2 years old) showed a higher filtering rate and production of feces- and pseudo-feces and less release of ammonium than the larger mussels. Third, if both are same in biomass, FRs and PF of mussels were higher in the low-density tank than the high-density tank, While the Concentration of $NH_4$-N and $PO_4$-P released WRS similar to each other (P>0.5). Therefore, these results suggest that CROM system using a young bivalve A. woordiana can be applied to control the nuisance seston in eutrophic lake system, if a relevant species and density were selected. Additional pilot tests to optimize the age and density of domestic bivalves were needed for the generalization of CROM operation.