• Title/Summary/Keyword: Palatal length

Search Result 84, Processing Time 0.019 seconds

Fitness of Adjustable Dental Impression Trays on the Caucasian and African American (백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Park, Yong-Suck;Kim, Yu-Lee;Oh, Sang-Cheon;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.185-192
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Caucasian and African American. Material and methods: The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. Sixty Caucasian (male:30, female:30) and sixty African American (male:30, female:30) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. Results: 1. Uniform impression material width was achieved by controling the width of the tray using stops and beveled guides. 2. In the maxillary tray on the Caucasian, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 13.0 mm. 3. In the maxillary tray on the African American, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 12.0 mm, posterior palatal part 11.0 mm and the labial frenum width was 11.0 mm. 4. In the maxillary tray on the African American, the impression material width of posterior border (0.8 mm) was measured to be small. 5. In the mandibular tray on the Caucasian, the impression material width was measured (2.7-6.7 mm) and posterior border width (2.1 mm) was measured small. The impression material length was measured (2.8-6.7 mm). 6. In the mandibular tray on the African American, the impression material width was measured to be rather great showing width of the labial frenum 9.2 mm and the width of posterior border was measured too small (0.3 mm). Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Caucasian and African American, we can take more easy and accurate dental impressions.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

A LONGITUDINAL STUDY ON THREE FACIAL GROWTH PATTERNS IN KOREANS WITH NORMAL OCCLUSION (정상교합자의 3가지 안면골 성장양상에 관한 누년적 연구)

  • Park, Krung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.273-286
    • /
    • 1995
  • The purpose of this study was to compare the difference of the growth aspects in three facial growth patterns. The biennial serial cephalometric radiographs of 33 samples(19males, 14females) with normal occlusion from 8.5 years to 18.5 yews of age were used in this study. The facial growth patterrn was categorized in 3 types(Drop type, Neutral type, Forward type) by the total amounts of the Y-axis which changed from 8.5 years to 18.5 years of age. The growth change of the craniofacial area during 10 years in each growth type was analyzed and was compared among the 3 growth types. The results of this study might be summarized as follows. 1. The samples that were classified by total change of the Y-axis during this study period were distributed to 52% of the neutral type, 27% of the forward type, 21% of the drop type. 2. The anterior growth of the maxilla to the cranial base(N per A) showed larger in the forward type than in other 2 types(p<0.05). 3. The palatal plane to the FH plane showed more anterior-superior inclination in the forward type with age during this study period. 4. The anterior growth of the mandible to the cranial base(N per Pog) appeared large in rank order, of largest the forward type, second the neutral type, and third the drop type(p<0.05). 5. During this study period the mandibular plane(SN/MN,FMA) showed more counterclockwise rotation in the forward type than in the drop type(p<0.05), and this tendency was stronger in males than in females(p<0.05). 6. The growth of the mandibular corpus length(Go-Me) showed smaller in the drop type than in the other 2 types(p<0.05). 7. In the forward type and the neutral type, the anterior growth of the mandible was larger than that of the maxilla(p<0.05). 8. In the craniofacial growth distances and angulations turned out to be somewhat variable, but the vertical proportion had a strong tendency whose original relation was maintained consistently during this study period. 9. Through these analyzed data, the profilograms on each growth type were constructed to evaluate individual growth pattern in the orthodontic diagnosis.

  • PDF

Embryotoxicity and Teratogenicity of Excess Zinc on Xenopus laevis (과량의 아연에 의한 아프리카 발톱개구리 (Xenopus laevis)의 배발생 이상과 독성)

  • Yoon, Chun-Sik;Jin, Jung-Hyo;Cheong, Seon-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.1 s.102
    • /
    • pp.83-94
    • /
    • 2003
  • Concentrated releases of zinc into water usually results from discharges associated with industrial purpose. The released zinc into soil is corroded and released into water. In aquatic environment, exess zinc is toxic to the organisms and causes the growth inhibition and malformation of them as a heavy metal. In this study, excess zinc toxicity was tested by FETAX (frog embryo teratogenetic assay with Xenopus)as in vivo system. Xenopus embryos at st.9 were exposed to $100{\sim}900\;{\mu}M$ of zinc for 7 days and 81% of individuals were survived in 100 ${\mu}M$, and 25% were survived in 1000M of zinc solution. In external malformations, swelled belly and intestinal dysplasia were common, and all of tested individuals showed these malformations in 200 ${\mu}M$ or higher concentration of zinc. In 400 ${\mu}M$ or higher concentration, all of tested tadpoles showed faded heart. Also, hypo-pigmentation, lens hernia and loose digestive track were very frequently found in 100 ${\mu}M$ of zinc. The histological study with paraffin section of zinc treated tadpoles showed following abnormalities; regeneration of photoreceptor on retina, reduced vitreous chamber in eye, reduction of red blood cells in heart, abnormal liver, swelling of pronephric cell, muscle dysplasia and palatal papilloma. These abnormalities may be caused by the degeneration of mitochondria, inhibition of cell adhesion, and the formation of leghemoglobin by zinc due to the substitution of $Ca^{2+}$ by $Zn^{2+}$. The body length was reduced due to the excess zinc. From a statistical result, body lengths of 300 ${\mu}M$ or higher concentrative g개ups was significantly reduced comparing that of control group. Recently, many spontaneous malformations and reduction of amphibians are reported, From the results of present study, excess zinc mi호t be a factor of amphibian reduction, and the control of zinc discharges is very important.