• Title/Summary/Keyword: Packing pressure

Search Result 250, Processing Time 0.028 seconds

Experiment and Simulation of 4-bed PSA for Hydrogen Separation from Multi-Component Mixture Gases (다성분 혼합 기체로부터 수소 분리를 위한 4-bed PSA 실험과 전산 모사)

  • Yang, Se-Il;Park, Ju-Yong;Jang, Seong-Cheol;Choi, Do-Young;Kim, Sung-Hyun;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.414-422
    • /
    • 2008
  • Adsorption experiments for $H_2$, $CH_4$, CO, $CO_2$ on activated carbon and zeolite 5A were performed by static volumetric method. A 4-bed pressure swing adsorption (PSA) process was to study separation of hydrogen from multi-component mixture gases ($H_2$ 72.2%, $CH_4$ 4.06%, CO 2.03%, $CO_2$ 21.6%). Dual-site langmuir (DSL) isotherm showed good or fair agreement with the experimental results. The optimum height of activated carbon layer was 55 cm with breakthrough results on the packing ratio of activated carbon to zeolite 5A. In PSA process, the effects of the process parameters such as total cycle time ($T_c$), ${\Delta}P$ at the provide purge step and adsorption pressure on the PSA performance were studied experimentally and theoretically.

Comparison of Molding Characteristics for Multi-cavity Molding in Conventional Injection Molding and Injection Compression Molding (다수 개 빼기 성형에서 일반사출성형과 사출압축성형의 성형특성 비교)

  • Lee, Dan Bi;Nam, Yun Hyo;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.144-149
    • /
    • 2014
  • Large residual stresses are remained in the conventional injection molded products because of the high cavity pressure in packing phase during injection molding process. Conventional injection molding (CIM) invokes distribution of cavity pressure and it has a limitation to obtain product with uniform physical property. Multi-cavity conventional injection molding contains quality deviation among the cavities since flow imbalance occurs during filling phase. Injection compression molding (ICM) is adopted to overcome these limitations of CIM. In this study, molding characteristics of CIM and ICM have been investigated using multi-cavity injection mold. Researches were performed by both experiment and computer simulation through observations of birefringence for transparent resins, polycarbonate and polystyrene in CIM and ICM. As a result, low and uniform birefringence and mold shrinkage were showed in the specimens by ICM that could give a uniform cavity pressure. Deviation of physical property among the specimens in multi-cavity mold shown in CIM was significantly reduced in the specimens by ICM. Through this study it was concluded that the ICM in multi-cavity molding was valid for molding products with uniform property in an individual cavity and also reduced property deviation among the cavities.

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Removal Characteristics of Nitrogen Oxides (NOx) in Low Concentration using Peat-Mixed Media (피트(peat) 혼합담체를 이용한 저농도 질소산화물(NOx) 제거특성)

  • Kang, Young-Heoun;Kim, Deok-Woo;Kang, Seon-Hong;Kwon, Pil-Joo;Kim, Dal-Woo;Hwang, Pil-Gi;Shim, Sang-Bo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.330-338
    • /
    • 2010
  • In this study, removal characteristics of nitrogen oxides $(NO_x)$ from road transport by using peat as the packing media for biodegradation have been investigated in the long term. Physicochemical and biological treatment of peatmixed media eliminates any requirement to use chemical substances and also facilitates the biodegradable actions of microorganism. Safe biodegradation of pollutants, no need to apply additional microbes owing to their active growth, and no generation of secondary pollutants were found in this experiment. It was concluded that average removal efficiencies of nitric oxide (NO) and nitrogen dioxide $(NO_2)$ were 80% and 97% respectively with respect to the linear velocity 35~40 mm/s and 0.3 ppm ozone concentration in the long period operation. Inflow concentration of nitric oxide over 0.05 ppm was suitable when pretreated with ozone. Non-ozone stage was performed with linear velocity 20~100 mm/s and then the average removal efficiency of nitric oxide and nitrogen dioxide were 38% and 94% respectively. Other results showed that the apparent static pressure was raised with increases in applied water content and aerial velocity in mixed media during fan operation.

Preparation of High Performance Hybrid Chemical Filter using Hot Melt Adhesive by Web Spray and Their Adsorption Properties (핫멜트 Web spray법을 이용한 고기능성 복합 화학필터의 제조 및 흡착특성)

  • Choi, Yong Jae;Shin, Kyoung Sub;Hwang, Taek Sung
    • Journal of Adhesion and Interface
    • /
    • v.10 no.3
    • /
    • pp.141-147
    • /
    • 2009
  • In this study, the high performance hybrid chemical filter (HPHCF) was prepared by web spray using hot melt adhesive. The material of HPHCF was conditionally made of ion exchange resin and PP non-woven fabric. The optimum temperature and pressure for manufacturing of HPHCF conditions were such as $170^{\circ}C$ and 50 psi, respectively. The characteristics of preparated HPHCF and their adsorption properties of ammonia gas were investigated. The ion exchange capacity (IEC) of HPHCF was increased with increasing the resin contents and their values were higher than pure resin and ion exchange fabrics. The removal efficiency for ammonia gas increased with the increase of packing density of hybrid ion exchange fabrics in the column. It showed 13 min which the adsorption breakthrough time was slower than resin and fibers. The maximum value of adsorption for ammonia gas was 98 percent. And also, the velocity was increased with increasing concentration and flow rate of ammonia gas.

  • PDF

A Study on the Fabrication for High Quality Ferrite Plastic Magnets (고품위 페라이트 본드자석 제조에 관한 연구)

  • 신용진;문형욱;진성빈;정왕일
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.440-446
    • /
    • 1997
  • This research has been performed for the fabrication of high quality ferrite plastic magnet. The magnetic properties of S $r_{5.9}$F $e_2$ $O_3$ ferrite bonded magnets by injection moulding with a variety of applied magnetic field were investigated. 0.3wt% CaCO3, 0.2wt% $SiO_2$, 0.5wt% $Al_2$ $O_3$and 0.5wt% N $a_2$ $SiO_3$are added in order to improve the magnetic properties of Sr-ferrite plastic magnets during the powder fabrication. For carbon coating on chemical compound specimen, 5wt% polyvinyl alcohol is added, and then calcinated under $N_2$ environment of 12$25^{\circ}C$. The particle size is distributed from 0.9~1.2${\mu}{\textrm}{m}$ which approximates to the single domain. The obtained Sr ferrite powder is well mixed with silane coupling and calcium stearate of 1wt%. Nest, the specimen is pelleted after kneading each of them with polyamidel2 as a binder. When the temperature of injection and mould were 25$0^{\circ}C$ and 8$0^{\circ}C$ respectively at injection pressure of 200kgf/$\textrm{cm}^2$, the degree of orientation was 85.3% under the applied magnetic field of 12kOe. As the results, when the packing density of Sr ferrite powder was 90wt%, the magnetic properties of Sr ferrite bonded magnet were follows : $_{B}$ $H_{c}$=2.41kOe, Br=3.1kG, (BH)$_{max}$=2.21MgOe. Especially, the Sr-ferrite bonded magnet with 10wt% N $d_2$F $e_{14}$B additive were as follows : $_{B}$ $H_{c}$=2.57kOe, Br=3.14kG and (BH)$_{max}$=2.39MGOe.GOe.GOe.GOe.e.

  • PDF

BLEEDING CONTROL BY CONTINUOUS WOUND DRAINAGE OF ACTIVE BLEEDING SITES OF TEETH EXTRACTION WOUND IN A PATIENT WITH ADVANCED LIVER CIRRHOSIS : REPORT OF A CASE (중증 간경변증 환자에서 발치창 과도 출혈부의 지속적 배농술을 통한 지혈 : 증례보고)

  • Mo, Dong-Yub;Yoo, Jae-Ha;Choi, Byung-Ho;Kim, Ha-Rang;Lee, Chun-Ui;Ryu, Mi-Heon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.431-436
    • /
    • 2009
  • There are five principal causes for excessive bleeding in the immediate postextraction phase ; (1) Vascular wall alteration (wound infection, scurvy, chemicals, allergy) (2) Disorders of platelet function (genetic defect, drug-aspirin, autoimmune disease) (3) Thrombocytopenic purpuras (radiation, leukemia), (4) Inherited disorders of coagulation (hemophilia, Christmas disease, vitamin deficiency, anticoagulation drug-heparin, coumarin). If the hemorrhage from postextraction wound is unusually aggressive, and then dehydration and airway problem are occurred, the socket must be packed with gelatine sponge(Gelfoam) that was moistened with thrombin and wound closure & pressure dressing are applied. The thrombin clots fibrinogen to produce rapid hemostasis. Gelatine sponges moistened with thrombin provide effective coagulation of hemorrhage from small veins and capillaries. But, in dental alveoli, gelatine sponges may absorb oral microorganisms and cause alveolar osteitis (infection). This is a case report of bleeding control by continuous rubber strip & iodoform gauze drainage (without gelfoam packing) of active bleeding infection sites of three teeth extraction wounds in a 46-years-old female patient with advanced liver cirrhosis.

Severe Recurrent Gingival Bleeding and Toothache Control in a Patient with Liver Cirrhosis and Oral Metastatic Hepatoma: Report of a Case (간경화증과 구강전이 간암환자에서 과도한 재발성 치은출혈과 치통조절: 증례보고)

  • Lee, Chun-Ui;Mo, Dong-Yub;Yoo, Jae-Ha;Choi, Byung-Ho;Kim, Jong-Bae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.592-596
    • /
    • 2010
  • The common local causes of active gingival bleeding are the vessel engorgement and erosion by severe inflammation and injury to hypervascularity lesion. Abnormal gingival bleeding is also associated with systemic bleeding disorders (liver disease, leukemia etc.). There are many conventional methods for gingival bleeding control, such as, direct pressure, packing, electrocoagulation, tight suture and application of hemostatic agents. If the continuous gingival bleeding is not stopped in spite of the all local application methods, the medical consultation should be obtained for systemic condition care and the major feeding arterial embolization. This is a case report of severe gingival bleeding and periodontitis control in a patient with liver cirrhosis and oral metastatic lesion of hepatocellular carcinoma. The bleeding lesion was placed in left buccal mucosa and gingiva of the left mandibular molars. The control methods were dental crown removal, primary endodontic drainage, gingival sulcus drainage and maxillary arterial embolization with medical consultation.

Residual stresses and viscoelastic deformation of an injection molded automotive part

  • Kim, Sung-Ho;Kim, Chae-Hwan;Oh, Hwa-Jin;Choi, Chi-Hoon;Kim, Byoung-Yoon;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.4
    • /
    • pp.183-190
    • /
    • 2007
  • Injection molding is one of the most common operations in polymer processing. Good quality products are usually obtained and major post-processing treatment is not required. However, residual stresses which exist in plastic parts affect the final shape and mechanical properties after ejection. Residual stresses are caused by polymer melt flow, pressure distribution, non-uniform temperature field, and density distribution. Residual stresses are predicted in this study by numerical methods using commercially available softwares, $Hypermesh^{TM},\;Moldflow^{TM}\;and\;ABAQUS^{TM}$. Cavity filling, packing, and cooling stages are simulated to predict residual stress field right after ejection by assuming an isotropic elastic solid. Thermo-viscoelastic stress analysis is carried out to predict deformation and residual stress distribution after annealing of the part. Residual stresses are measured by the hole drilling method because the automotive part selected in this study has a complex shape. Residual stress distribution predicted by the thermal stress analysis is compared with the measurement results obtained by the hole drilling method. The molded specimen has residual stress distribution in tension, compression, and tension from the surface to the center of the part. Viscoelastic deformation of the part is predicted during annealing and the deformed geometry is compared with that measured by a three dimensional scanner. The viscoelastic stress analysis with a thermal cycle will enable us to predict long term behavior of the injection molded polymeric parts.

Simultaneous Biofiltration of H2S, NH3 and Toluene using an Inorganic/Polymeric Composite Carrier

  • Park, Byoung-Gi;Shin, Won-Sik;Chung, Jong-Shik
    • Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.19-27
    • /
    • 2008
  • Simultaneous removal of ternary gases of $NH_3$, $H_2S$ and toluene in a contaminated air stream was investigated over 180 days in a biofilter. A commercially available inorganic/polymeric composite chip with a large void volume (bed porosity > 0.80) was used as a microbial support. Multiple microorganisms including Nitrosomonas and Nitrobactor for nitrogen removal, Thiobacillus thioparus (ATCC 23645) for $H_2S$ removal and Pseudomonas aeruginosa (ATCC 15692), Pseudomonas putida (ATCC 17484) and Pseudomonas putida (ATCC 23973) for toluene removal were used simultaneously. The empty bed residence time (EBRT) ranged from 60 - 120 seconds and the inlet feed concentration was $0.0325\;g/m^3-0.0651\;g/m^3$ for $NH_3$, $0.0636\;g/m^3-0.141\;g/m^3$ for $H_2S$, and $0.0918\;g/m^3-0.383\;g/m^3$ for toluene, respectively. The observed removal efficiency was 2% - 98% for $NH_3$, 2% - 100% for $H^2S$, and 2% - 80% for toluene, respectively. Maximum elimination capacity was about $2.7\;g/m^3$/hr for $NH_3$, > $6.4\;g/m^3$/hr for $H_2S$ and $4.0\;g/m^3$/hr for toluene, respectively. The inorganic/polymeric composite carrier required 40 - 80 days of wetting time for biofilm formation due to the hydrophobic nature of the carrier. Once the surface of the carrier was completely wetted, the microbial activity became stable. During the long-term operation, pressure drop was negligible because the void volume of the carrier was two times higher than the conventional packing materials.