Flow Properties of Micro Column Packed with Perfusive Particles (투과성 입자로 이루어진 미세 칼럼의 유동 특성)

  • Kim, Duck-Jong;Hwang, Yun-Wook;Park, Sang-Jin;Heo, Pil-Woo;Yoon, Eui-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.89-93
    • /
    • 2005
  • In this work, perfusive particles are used to form a micro column in a microfluidic chip and flow properties of the micro column are investigated. The packing flow velocity and the column/particle size ratio are shown to be important parameters affecting the packing density of the micro column. Experimental results show that the effect of the column/particle size ratio on the flow resistance of the micro column is negligible. This contrasts with previous works on the effect of the column/particle size ratio on the total pressure drop across the column.

  • PDF

Study on the Development of Simultaneous Analytical Method for the Residual Organic Chloride Pesticides by Gas Chromatography (기체 크로마토그래피를 이용한 유기 염소계 잔류 농약 동시 분석 방법 개발에 관한 연구)

  • Kim, Woo-Seong;Lee, Bong-Hun;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.561-567
    • /
    • 1996
  • A method for the simultaneous analysis of 31 residual organic chloride pesticides was studied using gas chromatography. Prepared analytical samples were injected to gas chromatography (HP 5890 Series II plus) on the Ultra-2 column with ECD. The packing materials for column were changed as the following reagents ; florisil and alumina N, The residual solution was loaded to column and was elected pith erection solvents ; ether : benzene (2 : 8) solution, hexane : benzene (1 : 1) solution, dichloromethane, acetone, and methanol. The analytical results showed that 6 kinds of organic chlorides were not detected when florisil (first condition) was used as the column packing material. The nondetected 6 kinds of organic chlorides in the first analytical condition were detected and the recoveries of thrin-pesticides were increased, in particular, captan and captafol, but the recoveries of benzene hexachloride compounds were decreased when dichloromethane and methanol were added as elution solvents (pac'king material was florisil as in the first condition). The recoveries of dichlornuanid, chlorofenvinfos, folpet, and dicofol were increased and that of aldrin was increased, but those of captan and captafol were not good when alumina N was used as the packing material. To detect simultaneously thrin-pesticides, captan, and captafol, florisil and alumina N were used as the packing materials. The elution result showed that captan and captafol were not detected. This was because the column was activated insufficiently. The analytical method was the best (31 kinds of organic chlorides in the residual pesticides were detected sharply and showed high sensitivity) when the column (packing materials were florisil and alumina N: together) was fuliy activated and the impurities were removed using various elution solvents.

  • PDF

A study on the column subtraction method applied to ship scheduling problem

  • Hwang, Hee-Su;Lee, Hee-Yong;Kim, Si-Hwa
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.401-405
    • /
    • 2004
  • Column subtraction, originally proposed by Harche and Thompson(]994), is an exact method for solving large set covering, packing and partitioning problems. Since the constraint set of ship scheduling problem(SSP) have a special structure, most instances of SSP can be solved by LP relaxation. This paper aims at applying the column subtraction method to solve SSP which can not be solved by LP relaxation. For remained instances of unsolvable ones, we subtract columns from the finale simplex table to get another integer solution in an iterative manner. Computational results having up to 10,000 0-1 variables show better performance of the column subtraction method solving the remained instances of SSP than complex branch-and-bound algorithm by LINDO.

  • PDF

A study on the column subtraction method applied to ship scheduling problem

  • Hwang, Hee-Su;Lee, Hee-Yong;Kim, Si-Hwa
    • Journal of Navigation and Port Research
    • /
    • v.28 no.2
    • /
    • pp.129-133
    • /
    • 2004
  • Column subtraction, originally proposed by Harche and Thompson(1994), is an exact method for solving large set covering, packing and partitioning problems. Since the constraint set of ship scheduling problem(SSP) have a special structure, most instances of SSP can be solved by LP relaxation This paper aim, at applying the column subtraction method to solve SSP which am not be solved by LP relaxation For remained instances of unsolvable ones, we subtract columns from the finale simplex table to get another integer solution in an iterative manner. Computational results having up to 10,000 0-1 variables show better performance of the column subtraction method solving the remained instances of SSP than complex branch and-bound algorithm by LINDO.

Development of Small Distillation Column for Performance Evaluation of Distillation Column (증류탑 성능평가에 적합한 소형 증류탑 개발)

  • Kim, Byoung Chul;Cho, Tae Je;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.668-671
    • /
    • 2010
  • A lab scale distillation experiment is conducted with small size packing used in lab scale multi-tray distillation equipment for the performance evaluation of distillation system. A sufficient surface are yielded with 6.7 mm cylindrical packings made of stainless steel, and a good liquid holdup and residence time are resulted. The comparison between the theoretical tray from the HYSYS and the experimental distillation outcome indicates that a 7 cm HETP from 27 cm packing height and a 8 cm HETP from 45 cm packing height are obtained. Comparing with the 8 cm HETP of commercial structured packing shows a similar experimental results obtained here. The 7 cm HETP is available with a complete insulation, and the importance of the insulation is proved. The results of this study indicates that a practical distillation column used in field can be tested in lab.

Mass Transfer and Hydraulic Kinematic Character Using Lattices Packings by Countercurrent Flow of Gas-Liquid Phase in Packing Column (격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성)

  • Kim, Jang-Ho;Ha, Sang-An
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.130-137
    • /
    • 1988
  • This thesis introduced that character of a treatment technique for a mading synthetic resin Hifiow-Ring. The material system of packings make an experiment air$NH_{3}$/air$H_{2}SO_{4}$, $SO_{2}$-air/NaOH, $NH_{3}$-air/$/H_{2}SO_{4}$ under general conditions. Lattices packing compared with conventional packings was proved low pressure loss and high separation efficiency for high loading per trans unit. And an inflow materal tested for absorption and rectification, it made an experiment under a range regular temperature, low energy and small amount of money. That made possible in simple equation, volume material tranfer coefficient$\beta_{L}$ . a by absorption or $\beta_{V}$ .a calculated in all range loading. The peculiarity pressure loss $\Delta\;P/NUT_{ov}$ for Hiflow-ring contributed to a fall cost of energy, a grade number of a vacuum rectification and absorption calculation.

  • PDF

Reductive Dechlorination of Groundwater Contaminated with PCE using Biobarrier: Column Study (생물벽체를 이용한 PCE로 오염된 지하수의 환원성 탐염소화: 칼럼 실험)

  • HwangBo, Hyun-Wook;Shin, Won-Sik;Song, Dong-Ik
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1147-1155
    • /
    • 2007
  • The applicability of in situ biobarrier or microbial filter technology for the remediation of groundwater contaminated with chlorinated solvent was investigated through column study. In this study, the effect of packing materials on the reductive dechlorination of PCE was investigated using Canadian peat, Pahokee peat, peat moss and vermicompost (or worm casting) as a biobarrier medium. Optimal conditions previously determined from a batch microcosm study was applied in this column study. Lactate/benzoate was amended as electron donors to stimulate reductive dechlorination of PCE. Hydraulic conductivity was approximately $6{\times}10^{-5}-8{\times}10^{-5}\;cm/sec$ and no difference was found among the packing materials. The transport and dispersion coefficients determined from the curve-fitting of the breakthrough curves of $Br^-$ using CXTFIT 2.1 showed no difference between single-region and two-region models. The reductive dechlorination of PCE was efficiently occurred in all columns. Among the columns, especially the column packed with vermicompost exhibited the highest reductive dechlorination efficiency. The results of this study showed the promising potential of in situ biobarrier technology using peat and vermicompost for the remediation of groundwater contaminated with chlorinated solvents.

Manufacturing of Packing Materials for 3D Printing and Evaluation of their Performances (3D 프린팅에 의한 충진물 제조 및 성능평가)

  • Lee, Hwa Young;Choi, Young Min;Hong, Yeon Ki
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.2
    • /
    • pp.33-36
    • /
    • 2015
  • In this paper, the development history of random packings for several generations was briefly introduced. We demonstrate the application of 3D printing to the fabrication of Pall rings, directly using computer aided design (CAD) models. The CAD was used to design Pall rings with different number of blades. The models were then printed by using UV curing of acrylonitrile-butadiene-styrene (ABS) resins. The results show that 3D printing is a promising method for producing precisely controlled packing materials. It is also expected that 3D printing is helpful for the fundamental studies of highly efficient packing materials with complex geometrical shapes.

On-Channel Micro-Solid Phase Extraction Bed Based on 1-Dodecanethiol Self-Assembly on Gold-Deposited Colloidal Silica Packing on a Capillary Electrochromatographic Microchip

  • Park, Jongman;Kim, Shinseon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.45-50
    • /
    • 2014
  • A fully packed capillary electrochromatographic (CEC) microchip with an on-column micro-solid phase extraction (SPE) bed for the preconcentration and separation of organic analytes was prepared. A linear microchannel with monodisperse colloidal silica packing was formed on a cyclic olefinic copolymer microchip with two reservoirs on both ends. Silver-cemented silica packing frit structure was formed at the entrance of the microchannel by electroless plating treatment as a base layer. A gold coating was formed on it by reducing $Au^{3+}$ to gold with hydroxylamine. Finally micro-SPE bed was formed by self-assembly adsorption of 1-dodecanethiol on it. Micro-SPE beds were about 100-150 ${\mu}m$ long. Approximately $10^3$ fold sensitivity enhancements for Sulforhodamine B, and Fluorescein in nM concentration levels were possible with 80 s preconcentration. Basic extraction characteristics were studied.

A Study on Strength and Packing Characteristics of Top-Down Joint in Field Experiment (현장실험을 통한 역타설 이음부의 강도 및 충전특성에 관한 연구)

  • 강동현;김종구;김병천;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1101-1106
    • /
    • 2000
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is to find a solution of removing void and air, way to exhaust air in top down column. through specimen concrete placing experiment.