• Title/Summary/Keyword: PZT-Actuator

Search Result 359, Processing Time 0.027 seconds

A study on the design and characteristics of an actuator for micro droplet ejecting system (미세 액적 토출 시스템의 구동기 설계 및 특성에 관한 연구)

  • Sim, Won-Chul;Kim, Young-Jae;Yoo, Young-Seuck;Joung, Jae-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2372-2373
    • /
    • 2005
  • The design of a piezoelectric actuator for micro droplet ejecting system has bee studied. The actuator has been evaluated by using commercial FEM package and its displacement are measured by LDV(Laser Doppler Vibrometer). The characteristics of the actuator are evaluated with varation in a ratio of width of PZT to that of membrane and thickness ratio of PZT to membrane.

  • PDF

Vibration Control of Beam using Piezoceramic Composite Actuator LIPCA (압전 복합재료 작동기 LIPCA를 이용한 보의 진동 제어)

  • Arief, Suhariyono;Goo, Nam-Seo;Park, hoon-Cheol;Yoon, Kwang-Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.4 s.23
    • /
    • pp.130-135
    • /
    • 2005
  • This paper presents application possibility of Lightweight Piezoceramic Composite Actuator(LIPCA) to suppress vibration of dynamic structures as an actuator. LIPCA is composed of a piezoelectric layer, a carbon/epoxy layer and glass/epoxy layers. When compared to the bare piezoelectric ceramic(PZT), LIPCA has advantages such as high performance, durability and reliability. In this study, performances of LIPCA have been estimated in an active vibration control system. Experiments were performed on an aluminum beam with cantilever configuration. In this test, strain gages and single LIPCA are attached on the aluminum beam with epoxy resin. Digital ON-OFF control algorithm is applied into the system to exhibit performance of LIPCA as actuator in active vibration control system. First, we performed static actuation test of bare PZT and LIPCA in order to show the superiority of LIPCA. Secondly, we carried out beam vibration control test using LIPCA. The results showed LIPCA could suppress free vibration of the aluminum beam, which means that LIPCA can be applied as an actuator to control vibration of dynamic structures.

Experiments on Vibration Control of Laminated Shell Structure with Piezoelectric Material (압전 재료를 이용한 셸형 복합적층판의 진동제어에 대한 실험)

  • 황우석;고성현;박현철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.153-156
    • /
    • 2003
  • Many researchers have tried to develop the piezoelectric shell element and verified them with the benchmarking problem of the piezoelectric bimorph beam since there is no experimental result for the control of shell structure with piezoelectric sensor/actuator. In this paper, the experiments are designed and performed to verify the control Performance of piezoelectric sensor/actuator on the shell structure. PVDF is easy to be attached on the surface of a shell structure but makes weak control forces. On the contrary, PZT makes control forces large enough to control the structure, but it is not easy to make a PZT element with curvature. To use PVDF as an actuator, the structure should be designed as flexible as possible and the voltage amplifier could make high control voltage. PVDF actuator powered by a voltage amplifier that generates output voltage from -200 to +200 volts, shows little control performance to control the vibration of an arch type shell structure. The performance of sensor looks good and the negative velocity feedback control works perfectly. The actuator voltage seems to be too small to verify the control effect Quantitatively. An experiment with high voltage amplifier is scheduled to verify the control effect Quantitatively.

  • PDF

The Determination of Transducer Locations for Active Structural Acoustic Control of the Radiated Sound from Vibrating Plate (평판에서 방사되는 소음의 능동구조소음제어를 위한 변환기의 위치결정)

  • 김흥섭;홍진석;이충휘;오재응
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.694-701
    • /
    • 2002
  • In this paper, through the study on locations of structural transducers for active control of the radiated sound from the vibrating plate, the active structural acoustic control (ASAC) system is proposed. And, for the evaluation of the proposed location, the experiment of the active structural acoustic control is implemented using the multi-channel filtered-x LMS algorithm and an additional filter (Acoustic Prediction Filter) to estimate the radiated sound using the acceleration signals of the plate. The structural transducers are piezoceramic actuator (PZT) and accelerometer. PZT is used as an actuator to reduce the vibration and the radiated sound. To maximize the control performance, each PZT actuator is located at the position that has the largest control sensitivity of the plate bending moment in the direction of x and y coordinates and the optimal PZT location is validated experimentally. Also, to find the acoustic prediction filter accurately, two accelerometers are located at the positions that have the largest radiation efficiencies of the plate, and the proposed locations are validated by simulation using the Rayleigh integral. The multi-channel filtered-x LMS algorithm is introduced to control a complex 2-D structural vibration mode. Finding the locations of structural transducers for active structural acoustic control of the radiated sound, the active structural acoustic control (ASAC) system can be presented and validated by experiments using a real time control system.

Effect of ZnO on Low Temperature Sintering of PMN-PNN-PZT Ceramics (ZnO가 PMN-PNN-PZT 세라믹스의 저온소결에 미치는 영향)

  • Lee, Sang-Ho;Yoo, Ju-Hyun;Hong, Jae-Il;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.32-33
    • /
    • 2006
  • In this study, in order to develop multilayer ceramic actuator for ultrasonic nozzle and ultrasonic vibrator, PMN-PNN-PZT ceramics were fabricated using $Li_2CO_3$. $Na_2CO_3$ and ZnO as sintering aids. And then, their piezoelectric and dielectric properties according to the amount of ZnO addition were investigated. The addition of ZnO improved density, dielectric constant, electromechanical coupling factor, mechanical quality factor and piezoelectric d constant of PMN-PNN-PZT ceramics due to the increase of sinterability and accepter doping effect. Electromechanical coupling factor and mechanical quality factor of PMN-PNN-PZT ceramics increased with ZnO amount up to 0.4wt% and then decreased. At the sintering temperature of $900^{\circ}C$ and 0.4wt% ZnO addition, density, dielectric constant, electromechanical coupling factor, mechanical quality factor and piezoelectric d constant showed the optimum value of 7.876g/$cm^2$, 1299, 0.612, 1151 and 369pC/N, respectively.

  • PDF

Piezoelectric Characteristics of PMW-PNN-PZT Ceramics according to Post-Annealing Process (Post annealing에 따른 PMW-PNN-PZT 세라믹스의 압전 특성)

  • Yoo, Kyung-Jin;Yoo, Ju-Hyun;Park, Chang-Yub;Lee, Hyung-Gyu;Kang, Hyung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.212-213
    • /
    • 2005
  • In this study, in order to develop low temperature sintering piezoelectric actuator, $Pb_{0.985}Bi_{0.01}(Mg_{1/2}W_{1/2})_{0.03}(Ni_{1/3}Nb_{2/3})_{0.13}(Zr_{0.50},Ti_{0.50})_{0.84}$ (PMW-PNN-PZT) ceramic systems were fabricated using $CaCO_3-Li_2CO_3$, sintering aid through a post-annealing process. The sinterability of PMW-PNN-PZT ceranics was remarkably enhanced by liquid phase sintering of $CaCO_3$ and $Li_2CO_3$. But, it was confimed form the X-ray diffraction pattern that the secondary phase along grain boundaries, deteriorated the piezoelectric properties. The secondary phase along grain boundaries was significantly removed by annealing after sintering. The 0.2wt% $Li_2CO_3$-0.25wt% $CaCO_3$-added PMW-PNN-PZT ceramics post-annealed at 900$^{\circ}C$ for 90min exhibited the excellent electromechanical coupling factor($k_p$) of 63.3% and piezoelectric constant($d_{33}$) of 452pC/N, respectively, for multilayer piezoelectricactuatorapplication.

  • PDF

Piezoelectric Characteristics of PZT-PSN Ceramics Depending on WO3Addition (PZT-PSN 세라믹스의 WO3의 첨가량에 따른 압전 특성)

  • 배숙희;김성곤;김철수;이경화;이상렬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.794-797
    • /
    • 2002
  • Piezoelectric properties of PZT-PSN ceramics were investigated as a function of WO$_3$ addition from 0 wt% to 6.0 wt%. The dielectric and piezoelectric characteristics of PZT-PSN ceramics have been investigated at different calcination (80$0^{\circ}C$~90$0^{\circ}C$) and sintering (110$0^{\circ}C$~130$0^{\circ}C$) temperatures. The grain size was increased with the addition of WO$_3$and the sintering temperatures. Anisotropic properties of electromechanical coupling coefficient and piezoelectric coefficient are proven to be dependent on processing temperatures and amount of addition. At the specimen with 0.6 wt% WO$_3$ addition, using calcination temperature of 80$0^{\circ}C$ and sintering temperature of 110$0^{\circ}C$ , mechanical quality factor(Q$_{m}$) and electromechanical coupling coefficient(k$_{p}$) showed the excellent results of 1560 and 0.48, respectively Experimental results indicated that the PZT-PSN system ceramics with WO$_3$impurity could be effectively used for the microtransformer and actuator applications, etc.etc.

Piezoelectric Characteristics of PZT-Based PZN-PNN-PZT Piezoelectric Devices According to Various Conditions (PZT 기반의 PZN-PNN-PZT 압전 소자의 다양한 조건에 따른 압전 특성 변화)

  • Choi, Jeoung Sik;Lee, Chang Hyun;Shin, Hyo Soon;Yeo, Dong Hun;Lee, Joon Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.11
    • /
    • pp.688-692
    • /
    • 2017
  • $Pb(Zr,\;Ti)O_3$ (PZT) is a piezoelectric material applied in a typical actuator and has been actively studied. However, in order to overcome the limitations of PZT, piezoelectric ceramics comprising mixed solid solutions of PZT with various relaxer electric materials have been studied. The $Pb(Zn_{1/3}Nb_{2/3})-Pb(Ni_{1/3}Nb_{2/3})-Pb(Zr,\;Ti)O_3$ (PZN-PNN-PZT) piezoelectric ceramic, known to have high piezoelectric constant and electromechanical coupling coefficient, was studied herein. The piezoelectric characteristics with various Zr contents (Zr/Ti ratios), PZN molar ratios, and sintering temperatures were compared. The piezoelectric properties of $d_{33}=580pC/N$ and $k_P=0.68$ were obtained with the $0.1PZN-0.2PNN-0.7PbZr_{0.46}Ti_{0.54}O_3$ composition sintered at $1,290^{\circ}C$.

Design and Implementation of a Vibration Transducer based on PZT Multi-layered Actuator for Implantable Middle Ear Hearing Devices (PZT 적층 압전체 기반의 인공중이용 트랜스듀서 설계 및 구현)

  • Park, I.Y.;Jung, E.S.;Seong, K.W.;Kim, M.W.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recently, implantable middle ear hearing devices (IMEHDs) have been developed to overcome the problems of conventional hearing aids. In this paper, a piezoelectric floating mass transducer (PFMT) based on a PZT multi-layered actuator has been designed and implemented using the approximated mechanical vibration modeling for the PFMT and the analysis of vibration characteristics through the transformation into the equivalent electrical model. The implemented PFMT has been attached to the ossicle of a human cadaver's temporal bone and the in-vitro experiment has been performed. Through the experimental results, it has been verified that the PFMT applied into our developed implantable middle ear hearing device can be used for an IMEHD transducer.

  • PDF