• Title/Summary/Keyword: PZT patches

Search Result 30, Processing Time 0.024 seconds

System identification of a building structure using wireless MEMS and PZT sensors

  • Kim, Hongjin;Kim, Whajung;Kim, Boung-Yong;Hwang, Jae-Seung
    • Structural Engineering and Mechanics
    • /
    • v.30 no.2
    • /
    • pp.191-209
    • /
    • 2008
  • A structural monitoring system based on cheap and wireless monitoring system is investigated in this paper. Due to low-cost and low power consumption, micro-electro-mechanical system (MEMS) is suitable for wireless monitoring and the use of MEMS and wireless communication can reduce system cost and simplify the installation for structural health monitoring. For system identification using wireless MEMS, a finite element (FE) model updating method through correlation with the initial analytical model of the structure to the measured one is used. The system identification using wireless MEMS is evaluated experimentally using a three storey frame model. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS estimates system parameters with reasonable accuracy. Another smart sensor considered in this paper for structural health monitoring is Lead Zirconate Titanate (PZT) which is a type of piezoelectric material. PZT patches have been applied for the health monitoring of structures owing to their simultaneous sensing/actuating capability. In this paper, the system identification for building structures by using PZT patches functioning as sensor only is presented. The FE model updating method is applied with the experimental data obtained using PZT patches, and the results are compared to ones obtained using wireless MEMS system. Results indicate that sensing by PZT patches yields reliable system identification results even though limited information is available.

Health monitoring of steel structures using impedance of thickness modes at PZT patches

  • Park, Seunghee;Yun, Chung-Bang;Roh, Yongrae;Lee, Jong-Jae
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.339-353
    • /
    • 2005
  • This paper presents the results of a feasibility study on an impedance-based damage detection technique using thickness modes of piezoelectric (PZT) patches for steel structures. It is newly proposed to analyze the changes of the impedances of the thickness modes (frequency range > 1 MHz) at the PZT based on its resonant frequency shifts rather than those of the lateral modes (frequency range > 20 kHz) at the PZT based on its root mean square (RMS) deviations, since the former gives more significant variations in the resonant frequency shifts of the signals for identifying localities of small damages under the same measurement condition. In this paper, firstly, a numerical analysis was performed to understand the basics of the NDE technique using the impedance using an idealized 1-D electro-mechanical model consisting of a steel plate and a PZT patch. Then, experimental studies were carried out on two kinds of structural members of steel. Comparisons have been made between the results of crack detections using the thickness and lateral modes of the PZT patches.

Looseness Estimation of Bolts on Truss Structure with PZT Patches

  • Jiang, Zhongwei;Akeuchi, Yasutaka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.86.6-86
    • /
    • 2002
  • This work presents a study on development of a practical and quantitative technique for assessment of the healthy state of a structure by piezoelectric impedance-based technique associated with longitudinal wave propagation measuring method. A truss structure embedded with piezoelectric patches is investigated for a fundamental study on estimation of the looseness of bolts in the joint. In order to evaluate the minute mechanical impedance change due to loosening bolt, a harmonic longitudinal elastic wave is applied to the structure by a pair of PZT patches and their electric impedance is measured simultaneously. According to the experimental results, the change of the electric impedance of P...

  • PDF

Monitoring of Strength Gain in Concrete Using Smart PZT Transducers

  • Qureshi, Adeel Riaz;Shin, Sung-Woo;Yun, Chung-Bang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.501-508
    • /
    • 2007
  • This paper presents the feasibility of using electromechanical impedance based active sensing technique for nondestructive strength gain monitoring of early-age concrete by employing piezoelectric lead-zirconate-titanate (PZT) patches on concrete surface. The strength development of early age concrete is actively monitored by performing a series of experiments on concrete specimens under moist curing condition. The electrical admittance signatures are acquired for five different curing ages and compared with each other. The resonant frequency shifts of PZT patches with increasing days is observed which is on account of additional stiffening due to strength gain of concrete during curing and level of stiffening being related to strength obtained from compression tests on companion cylinder specimens. The proposed approach is found to be suitable for monitoring the development of compressive strength in early-age concrete. It is also observed in this study that root mean square deviation (RMSD) in admittance signatures of the PZT patches can also be used as an indicator of concrete strength development.

A Study on Square-Structure Estimation of Fastening Condition of Bolt Using PZT Patches (PZT를 이용한 사각구조물 볼트체결상태 계측에 관한 연구)

  • Chae, Kwan-Seok;Ha, Nam;Hong, Dong-Pyo;Chae, Hee-Chang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.860-863
    • /
    • 2005
  • This work presents a study on development of a practical and quantitative technique for assessment of the structural health condition by PZT impedance-based technique associated with longitudinal wave propagation. The bolt fastening condition is adjusted by torque wrench In order to estimate the damage condition numerically, we suggest the evaluation method of impedance peak frequency shift $\Delta$F in this paper.

  • PDF

Strength Development Monitoring of Concrete Using Smart PZT Transducers

  • Sung, Woo-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.573-574
    • /
    • 2009
  • The feasibility of electro-mechanical impedance (EMI) sensing technique, utilizing piezo-ceramic (PZT) patches, for online strength gain monitoring of early age concrete is investigated. An experimental study is conducted on PZT patch instrumented concrete specimens. The applicability of the EMI sensing technique for strength gain monitoring is discussed.

  • PDF

Vibration Control of Hvbrid Smart Structure Using PZT Patches and ER Fluids (PZT와 ER유체를 적용한 복합지능구조물의 진동제어)

  • Yun, Shin-Il;Park, Keun-Hyo;Han, Sang-Bo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.734-739
    • /
    • 2003
  • Many types of smart materials and control laws are available to actively adjust the structure from various external disturbances. Usually, a certain type of control laws to activate a specific smart material is well established, but the effectiveness of the control scheme is limited by the choice of the smart materials and the responses of the structure. ER fluid is adequate to provide relatively large control force, on the other hand, the PZT patches are suitable to provide small but arbitrary control forces at any point along the structure. It was found that active vibration control mechanism using ER fluid failed to suppress the excitation off the resonant frequency with changed structural characteristics along the frequency response function of the closed loop of the control system. To compensate this additional peak of the closed loop system, PPF control using PZT as an actuator is added to construct a hybrid controller.

  • PDF

A Study on Structure Minute Damage Assessment by Using PZT Patches (PZT를 이용한 구조물 미소손상 평가에 관한 연구)

  • Kim, Byung-Jin;Han, Su-Hyun;Hong, Dong-Pyo;Tae, Sin-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.201-205
    • /
    • 2005
  • This work presents a study on development of a practical and quantitative technique for assessment of the structural health condition by piezoelectric Impedance-based technique associated with longitudinal wave propagaation. The natural frequency of the object has a tendency of frequency shifting according to hole size corresponded to real structure crack and crack size. In order to estimate the damage condition numerically, we suggest the evaluation method of Impedance peak frequency shift hF in this paper.

  • PDF

Vibration Control of Hybrid Smart Structure Using ER Fluids and Piezoelectric Ceramics (전기점성유체와 압전세라믹을 이용한 복합지능구조물의 진동제어)

  • 윤신일;박근효;한상보
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.8
    • /
    • pp.612-618
    • /
    • 2003
  • A hybrid vibration control scheme using ER fluid and PZT patches is proposed. Dynamic characteristics of the beam embedded with the ER fluid can be controled by changing the strength of the electric field applied on the ER fluid, thus provides a mean to avoid the resonance. It was found that active vibration control of the structure embedded with ER fluid failed to suppress the vibration excited with broad band frequency due to the limited change of the dynamic characteristics of the structure. To compensate this limited effect of the control scheme with ER fluid alone, PPF control using PZT patches as sensors and actuators is added to construct a hybrid controller. Experimental results suggests that proposed hybrid controller is effective to suppress the additional resonance vibration that appears when each controller is used alone.

Study of Bolt Coupling Torque Conclusion of TRUSS Structure Using PZT Patches (압전소자를 이용한 TRUSS 구조물의 볼트 결합 토크 추정에 관한 연구)

  • Hyun, Han-Su;Kim, Byung-Jin;Hong, Dong-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.612-615
    • /
    • 2005
  • This studies presented truss frame which use aluminum beam by damage model. Truss frame which each joint part is contracted by bolt contracted conclusion of each bolt by 3.0 N/m. And measured impedance change that appear making bolt 0.5 N/m on damage condition 8 times. Compares impedance change of 5 segments that was set by measurement area and displayed result. To measure torque change of bolt, other damage model did not apply.

  • PDF