• Title/Summary/Keyword: PZT Sensors

Search Result 157, Processing Time 0.023 seconds

A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor (부착형 고분자 압전센서를 이용한 탄성파 검출 연구)

  • Kim, Ki-Bok;Yoon, Dong-Jin;Kueon, Jae-Hwa;Lee, Young-Seop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.268-274
    • /
    • 2004
  • Patch type piezo-polymer sensors for smart structures were experimented to detect elastic wave. The pencil lead braking test was performed to analyze the characteristics of patch-type piezo-polymer sensors such as polyvinyliden fluoride (PVDF) and polyvinylidene fluoride trifluorethylene (P(VDF-TrFE)) for several test specimens with various elastic wave velocities and acoustical impedances. The characteristics of the patch-type piezo-polymer sensor were compared with the commercial PZT acoustic emission (AE) sensor. The vacuum grease and epoxy resin were used as a couplant for the acoustic impedance matching between the sensor and specimen. The peak amplitude of elastic wave increased as the diameter of piezo-film and acoustical impedance of the specimen increased. The frequency detection range of the piezo-film sensors decreased with increasing diameter of the piezo-film sensor. The P(VDF-TrFE) sensor was more sensitive than the PVDF sensor.

Validation of Piezoelectric Sensor Diagnostics Algorithm Using Instantaneous Baseline Data (Admittance를 기반으로 한 센서 자가 진단 알고리즘의 실험적 검증 - 상호비교를 통한 센서 결함 탐지)

  • Jo, HyeJin;Jung, Hwee Kwon;Park, Tong il;Park, Gyuhae
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.148-154
    • /
    • 2015
  • In order to detect damage in early stages and properly maintaining structures, the structural health monitoring technology is employed. In most cases, active-sensing SHM needs many piezoelectric (PZT) sensors and actuators. Thus, if there is a defect on PZT used for active-sensing SHM, the structural status could be misclassified. This study, for reliable SHM performance, investigated to detect defects of sensors by using the admittance-based sensor diagnostics. This study also introduced an algorithm that can diagnose sensor defects based only on data measured from the sensors in case that information about the changes in adhesive and environmental investigation, this study confirms that the proposed algorithm could be efficiently applied to real-world structures in which a significant temperature variation could take place.

Design of Ultra-precision Micro Stage using Response Surface Methodology (반응표면분석법을 이용한 초정밀 마이크로스테이지의 설계)

  • Ye, Sang-Don;Min, Byeong-Hyeon;Lee, Jae-Kwang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.1
    • /
    • pp.39-44
    • /
    • 2006
  • Ultra precision positioning mechanism has been widely used on semiconductor manufacturing equipments, optical spectrum analyzers and cell manipulations. Ultra precision positioning mechanism consists of several actuators, sensors, guides and control systems. Its efficiency depends on each performance of components. The object of this study is to design and analyze the micro stage that is one of the equipments embodied in ultra precision positioning mechanism. The micro stage consists of PZT actuators and flexure hinges. The structural design of flexure hinge is optimized by using RSM and FEM. The control factors concerned with the design of flexure hinges of stage and arms are optimized by minimizing the equivalent stress on the hinge and maximizing 1st natural frequency based on RSM and FEM simulation under various kinds of design conditions.

  • PDF

Local/Global Structural Health Monitoring System by means of Piezoelectric Sensors (압전센서를 이용한 구조물 국부/광역 손상 진단 시스템)

  • Kim, Byung-Soo;Kywon, Hyuck-Sang;Kim, Jin-Wook;Roh, Yong-Rae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.2-5
    • /
    • 2009
  • 본 논문에서는 오실레이터 센서와 램파 센서를 결합하여 구조물 손상 진단을 위한 통합된 압전 센서 시스템을 제안한다. 구조물 손상으로 인한 공진주파수 변화를 관측할 수 있는 오실레이터 센서는 손상 정도에 민감하게 반응하고 구조가 단순한 장치이지만 측정 범위가 센서 주위로 제한되는 특성을 가진다. 반면에 램파를 이용한 진단 시스템은 원거리에 위치한 구조물의 손상부를 감지하기에 유용하다. 본 논문에서는 오실레이터 센서를 이용한 취약 지점의 국부적인 손상 진단 방식과 램파를 이용한 광역적인 손상 진단 방식을 결합하여 각 시스템의 장점들을 활용할 수 있는 센서 시스템의 적용가능성을 연구하였다. PZT소자를 알루미늄 판에 적용하여, 알루미늄판의 손상 정도에 따른 오실레이터 공진주파수의 변화와 램파 신호의 Time of flight, 그리고 진폭의 변화를 이용하여 구조물 손상형태의 판별 가능성을 제시하고 실험을 통하여 그 타당성을 검증하였다.

  • PDF

Vibration Control of Hybrid Smart Structure Using ER Fluids and Piezoelectric Ceramics (전기점성유체와 압전세라믹을 이용한 복합지능구조물의 진동제어)

  • 윤신일;박근효;한상보
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.8
    • /
    • pp.612-618
    • /
    • 2003
  • A hybrid vibration control scheme using ER fluid and PZT patches is proposed. Dynamic characteristics of the beam embedded with the ER fluid can be controled by changing the strength of the electric field applied on the ER fluid, thus provides a mean to avoid the resonance. It was found that active vibration control of the structure embedded with ER fluid failed to suppress the vibration excited with broad band frequency due to the limited change of the dynamic characteristics of the structure. To compensate this limited effect of the control scheme with ER fluid alone, PPF control using PZT patches as sensors and actuators is added to construct a hybrid controller. Experimental results suggests that proposed hybrid controller is effective to suppress the additional resonance vibration that appears when each controller is used alone.

Hardware Implementation of High-Speed Active Vibration Control System Based on DSP320C6713 Processor

  • Kim, Dong-Chan;Choi, Hyeung-Sik;Her, Jae-Gwan;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • This paper deals with the experimental assessment of the vibration suppression of the smart structures. First. we have presented a new high-speed active control system using the DSP320C6713 microprocessor. A peripheral system developed is composed of a data acquisition system, N/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers for fast data processing. Next, we have tested the processing time of the peripheral devices, and provided the corresponding test results. Since fast data processing is very important in the active vibration control of the structures, we have focused on achieving the fast loop times of the control system. Finally, numerous experiments were carried out on the aluminum plate to validate the superior performance of the vibration control system at different control loop times.

Analytical Estimation of Power Generation from Dynamic Structure With Piezoelectric Element (압전재료가 부착된 동적 구조물로부터 발생되는 전기력의 해석적인 평가)

  • Oh, Jae-Eung;Yoon, Ji-Hyeon;Sim, Hyoun-Jin;Lee, You-Yub
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.263-263
    • /
    • 2007
  • In the future, self-contained sensors and processing units will need on-board, renewable power supplies to be truly autonomous. One way of supplying such power is through energy harvesting, processes by which ambient forms of energy are converted into electricity. One energy harvesting technique involves converting kinetic energy, in the form of vibrations, into electrical energy through the use of piezoelectric materials. Researchers are currently investigating how piezoelectric materials can be used to harvest power. This study examines the use of auxiliary structures, consisting of a mechanical fixture and a lead zirconate/lead titanate (PZT) piezoelectric element, which can be attached to any boundary conditions vibrating beam of the any boundary conditions. Adjusting various boundary conditions of these structures can maximize the strain induced in the attached PZT element and improve power output.

  • PDF

PZT5 spherical hydrophone simulation using a coupled FE-BE method (결합형 유한요소-경계요소 기법을 활용한 PZT5 구형 수중 수파기 시뮬레이션)

  • Jarng, Soon-Suck
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.377-385
    • /
    • 1998
  • This paper describes the application of a coupled finite element-boundary element method to obtain the steady-state response of a hydrophone. The particular structure considered is a flooded piezoelectric spherical shell. The hydrophone is three-dimensionally simulated to transduce an incident plane acoustic pressure onto the outer surface of the sonar spherical shell to electrical potentials on inner and outer surfaces of the shell. The acoustic field formed from the scattered sound pressure is also simulated. And the displacement of the shell caused by the externally incident acoustic pressure is shown in temporal motion. The coupled FE-BE method is described in detail.

  • PDF

Silicon Nitride Cantilever Array Integrated with Si Heaters and Piezoelectric Sensors for Probe-based Data Storage

  • Nam Hyo-Jin;Kim Young-Sik;Lee Caroline Sunyong;Jin Won-Hyeog;Jang Seong-Soo;Cho Il-Joo;Bu Jong-Uk
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.73-77
    • /
    • 2005
  • In this paper, a new silicon nitride cantilever integrated with silicon heater and piezoelectric sensor has been firstly developed to improve the uniformity of the initial bending and the mechanical stability of the cantilever array for thermo-piezoelectric SPM(scanning probe microscopy) -based data storages. This nitride cantilever shows thickness uniformity less than $2\%$. Data bits of 40 nm in diameter were recorded on PMMA film. The sensitivity of the piezoelectric sensor was 0.615 fC/nm after poling the PZT layer. For high speed operation, 128${\times}$128 probe array was developed.

  • PDF

Innovative cable force monitoring of stay cables using piezoelectric dynamic strain responses

  • Nguyen, Khac-Duy;Huynh, Thanh-Canh;Lee, Ji-Yong;Shin, Sung Woo;Kim, Jeong-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.830-834
    • /
    • 2013
  • This study presents a method to monitor cable force of a long-span cable-stayed bridge using a smart piezoelectric sensor system. The following approaches are implemented in order to achieve the objective. Firstly, the method to utilize piezoelectric materials for the health monitoring of stay cables is presented. For strain measurement of a stay cable, a PZT-embedded smart skin is designed to overcome the difficulties of bonding PZT sensors directly on stay cables. Secondly, a piezoelectric strain monitoring system for stay cables is designed. For the operation of the sensor board, the Imote2 sensor platform is used to provide the computation, wireless communication and power supply units. The feasibility of the proposed monitoring system is then evaluated on a full-scale cable of a cable-stayed bridge.

  • PDF