• Title/Summary/Keyword: PWM Method

Search Result 1,343, Processing Time 0.03 seconds

A Study on Two Stage PFC Full-Bridge Converter with a Single PWM Controller (단일 PWM 제어기에 의한 역률보상 이단 풀 브리지 컨버터에 관한 연구)

  • Jeon, Joon-Sang;Kim, Yong;Kwon, Soon-Do;Kim, Pil-Soo;Yoon, Suk-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.368-371
    • /
    • 2000
  • Two-stage power factor correction (PFC) converter with a single PWM controller is proposed. It consists of a power factor pre-regulator cascaded by an isolated DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. This converter gives the goof power factor correction, low line current harmonic distortions, and tight output voltage regulations. This converter also has a high efficiency by employing an soft switching method. The proposed approach has advantages such as high performance over the single-stage approach and low cost over two-stage approach. The experimental results obtained on a 300W (30V/10A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

Transformer-less Inverter for Photovoltaic and small unit Windturbine System (태양광 및 소단위 풍력발전용 변압기 없는 인버터)

  • 박영산
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.407-412
    • /
    • 2004
  • Designed transformer-less inverter for photovoltaic and small unit windturbine power system. This system consisted of boost chopper circuit of multiple-switching method and full bridge PWM inverter. Transformer-less system was adapted to reduce cost and size. But in this system, earth-leakage current have to be considered. So, to solve this problem, we used PWM inverter switching method to reduce the earth-leakage current which flows in accordance with the variation of DC input common mode voltage.

The Analysis of Noise Characteristics of Synchronous Reluctance Motor in the two-phase conduction operation (2상 통전 방식에 따른 동기 리럭턴스 모터의 소음 특성 분석)

  • 오재윤;정달호;김정철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.167-170
    • /
    • 1999
  • In this paper, we operate Synchronous Reluctance Motor(SynRM) using the two-phase conduction method. Acually SynRM is operated by the sinusoidal PWM method but in home-appliance there is many restrictions of making the motor such as the method of winding, the shape of rotor etc. Therefore it is possible that there is little difference of performance between the two-phase conduction method and the sinusoidal PWM method. In this paper the characteristics of motor noise will be analyzed especially in the case of using the two-phase conduction method by experiment results.

  • PDF

A New PWM Method and its Implementation for a 3-Level Inverter Considering DC-Link Voltage Balancing and Minimum ON/Off Time (DC-링크 전압균형과 소자의 최소 온/오프 시간을 고려한 3-레벨 인버터의 PWM 기법 및 구현)

  • 이요한;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.35-38
    • /
    • 1998
  • In this paper, we present a new SVPWM strategy for a 3-level inverter. This SVPWM method is easily implemented without switching table like SVPWM. In addition, with proposed method, we can also keep the voltage balancing of DC-link capacitors and guarantee minimum on/off time of the devices. The principle of the proposed SVPWM method is described in detail, and its implementation method is also proposed. The usefulness of the proposed SVPWM method is verified through the simulation using MATLAB/Simulink.

  • PDF

A Study on The MRA PWM Technique Using the Trapezoidal Waveform at Voltage Source Inverter(VSDI) (전압형 인버터(VSI)에서 사다리꼴파형을 이용한 MRA PWM 기법에 관한 연구)

  • 한완옥;원영진;이성백
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 1993
  • In order to improve complicated construction and complex control which are disadvantage of optimal PWM technique aimed at harmonic elimination method, this paper presented MRA(Model Reference Adaptive) PWM technique that gatmg signal of inverter is generated by comparing the reference signal with the induced feedback signal at the reference model of load. Design of controller is composed of microprocessor and analog circuit. MRA PWM technique used in the paper is able to compensate the degradation of voltage efficiency to be generated by the ratio of the output voltage to the DC supply voltage being low for using conventional sinusoidal PWM technique. When the trapezoidal signal is employed as the reference signal. the low order harmonics of line current can be reduced and the switching pattern is made by on-line computation using comparatively simple numerical analysis.

  • PDF

An Optimized PWM Switching Strategy for an Induction Motor Voltage Control (전압제어 유도 전동기를 위한 최적 PWM 스위칭 방법)

  • Han, Sang-Soo;Chu, Soon-Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.922-930
    • /
    • 2009
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses and has been therefor recognized the preferred PWM method especially in case of digital implementation. An optimized PWM switching strategy for an induction motor voltage control consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The preferred switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by using the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

Voltage Source Equipment for the Grid Fault Testing and Analysis of Total Harmonic Distortion According to PWM Methods

  • Gwon, Jin-Su;Kim, Chun-Sung;Kang, Dae-Wook;Park, Jung-Woo;Kim, Sungshin
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1081-1092
    • /
    • 2014
  • Renewable energy is being spotlighted as the electric power generating source for the next generation. Due to an increase in renewable energy systems in the grid system, their impact on the grid has become non-negligible. Thus, many countries in the world, including Europe, present their own grid codes for grid power conversion devices. In order to experiment with these grid codes, grid fault test equipment is required. This paper proposes both equipment and a control method, which are constructed with a 7-level cascaded H-bridge converter, that are capable of generating various grid faults. In addition, the Pulse Width Modulation (PWM) method for multilevel converters is compared and analyzed. The proposed structure, the control method, and the PWM method are verified through simulation and experimental results.

Zero-Transient Current Control Method for PWM Dimming of LED (LED의 펄스폭 변조를 통한 휘도조절시 과도구간이 존재하지 않는 전류 제어 기법)

  • Yoon, Young-Nam;Lee, Sang-Hyun;Cho, Sang-Ho;Hong, Sung-Soo;Kim, Chang-Sub;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.64-70
    • /
    • 2011
  • This paper presents a zero-transient current control method for PWM dimming of LED. Since the proposed LED current control method has no transient state, it features a high resolution, high linearity, and no current overshoot through LED along a wide dimming range. The operational principles of the proposed LED current control circuit are presented. To confirm the validity of the proposed method experimental results from a prototype circuit of the 46-inch LCD TV are given.

A Study on Strobe Control over LED Lighting System for Machine Vision (머신비전을 위한 LED 조명시스템의 스트로브 제어 구동에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.121-125
    • /
    • 2021
  • The machine vision technology has been widely used in the industrialized nations like the United States, Japan, and EU in the various industries from the late 1980s. Machine vision inspection system mainly consists of a camera, optics, illumination and an image acquisition system. Optimization of the illumination light source is very important. This paper shows a comparison between Pulse Width Modulation (PWM) control and strobe control in driving LED lighting system for machine vision. PWM control method has problems such as a temperature rising of LED and a flickering in image measurement for inspection. In contrast, the proposed strobe control method can suppress the temperature of LED light source below 40℃. Also, it can remove the flickering problem through a synchronization between a frame grabber and a camera shutter. Finally, the strobe control method was shown to extract clearer images with a high precision compared to PWM control method.