• 제목/요약/키워드: PWM Half bridge resonant inverter

검색결과 15건 처리시간 0.025초

LCD 조광용 냉음극 형광램프의 구동 및 제어 (The Drive and Control Circuit Design of Cold Cathode Fluorescent Lamp for LCD Back Lighting)

  • 김철진;홍대식;황요한;윤신용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1211-1213
    • /
    • 2004
  • CCFL(cold cathode fluorescent lamp) are used to backlight of LCD(liquid crystal display). CCFL dimming methods are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, design of CCFL driving and control circuit by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. Inverter switching frequency is higher than resonant frequency for stable operating, and it is possible dimming control. On the basis of equivalent circuit, the validity of this study is confirmed by the comparison of simulation and experimental result.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

표시장치에 적용되는 CCFL의 모델과 인버터 구동 (A Modeling and Driving Performance for CCFL Applied to the Display Unit)

  • 김철진;유병규;윤신용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.197-199
    • /
    • 2005
  • The Cold cathode fluorescent lamp (CCFL) are widely used to illuminate the liquid crystal display(LCD). Ballasts are required for CCFL because the lamp need high starting voltage and behave negative dynamic resistant characteristics in the desired region of operation. Dimming methods of CCFL are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, CCFL driving and control circuit is designed by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. The validity of this study is confirmed from the simulation and experimental results.

  • PDF

고주파 구동 냉음극 형광방전램프의 시뮬레이션 모델 (A Simulation Model of Cold Cathode fluorescent Lamp for High Frequency operation)

  • 김철진;유병규;윤신용;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1503-1505
    • /
    • 2005
  • The Cold cathode fluorescent lamp(CCFL) are widely used to illuminate the liquid crystal display(LCD). Ballasts are required for CCFL because the lamp need high starting voltage and behave negative dynamic resistant characteristics in the desired region of operation. Dimming methods of CCFL are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, CCFL driving and control circuit is designed by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. The validity of this study is confirmed from the simulation and experimental results.

  • PDF

LCD TV HV-BLU 시스템에 대한 Ultra-FRFET의 유효성에 관한 연구 (A Study on the Effectiveness of Ultra-FRFET for the HV-BLU System in LCD TVs)

  • 이상택;연재을;조규민;김희준
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1394-1400
    • /
    • 2010
  • This paper introduces a newly improved Ultra-FRFET that has much better reverse recovery characteristic than that of the typical MOSFET and presents its effectiveness in the HV-BLU system of LCD TVs. The reverse recovery time, $T_{rr}$ of Ultra-FRFET is shorter than 40nsec and the peak value of reverse current, $i_{rr}$ is also much smaller compared to the typical MOSFET's, which are sufficient to prevent the MOSFET’s failures without additional FRDs and diodes in HV-BLU system with a half-bridge resonant inverter topology worked by PWM method. In order to verify the validity, the loss analysis and the implementation results in cases when both the conventional solution using typical MOSFETs with additional FRDs and a new solution using Ultra-FRFETs are applied to a HV-BLU of 40" LCD TV are presented. As a result, the effectiveness of Ultra-FRFET was verified and the results are presented in this paper.