고역률 PWM CONVERTER를 적용한 UPS (PWM Converter with Unity Power Factor for UPS systems)

  • 이우철;서인영;이범희;서동휘;권성곤;김성우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.753-755
    • /
    • 1993
  • Full Bridge Diode Rectification and Phase Controlled SCR Rectification are the most widely used methods of power conversion($AC{\rightarrow}DC$) in Power Electronic products such as UPS systems. But using these types of converters can lead to the following problems. First, they generate harmonics on the AC input side, which can cause interference in other equipment connected to the same commercial power line. Second, they deteriorate the power factor so that the input power capacity or the equipment becomes larger than the actual rated output capacity. As a means to overcome these problems an IGBT type PWM Converter, which applies a current control algorithm, is proposed. In this paper the enhancement of the converter performance is shown through simulation.

  • PDF

3상 임베디드 Z-소스 인버터 (Three Phase Embedded Z-Source Inverter)

  • 오승열;김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

SVPWM을 이용한 전기철도용 회생 인버터 개발 (Development of Regenerative Inverter for Electric Railway Using Space Vector PWM)

  • 정문구;백병산;김태완;류승표;김남해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.15-18
    • /
    • 2003
  • The electric power, regenerated while railway vehicles braking or running downhill, makes U line voltage rise and the feeding system may not be secure. In order to keep away from these kind of insecurity, the regenerative energy should be consumed by loads or transmitted to the AC side via certain devices such as DC/AC converters. This paper introduces the developed regenerative inverter for electric railway.

  • PDF

고압 나트륨 램프 구동용 전력변환장치의 역률 개선 (Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps)

  • 이상현;서기영;이현우;이수흠;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

$\Delta$ 변환기 후단 처리용 고선형 저전력 연속시간 필터의 설계 (A design of high-linearity low-power contiunous-time filter for post-processing of .SIGMA..DELTA. converters)

  • 홍국태;정현택;손한웅;염왕섭;정강민
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1579-1589
    • /
    • 1997
  • This paper introduces a monolithic chip 3.3V high-performance continuous-tune filter used in a CDP that can reconstruct the PDM or PWM signal output of a .SIGMA..DELTA. D/A converter. We also mentioned an active RC filter structure and filter order satisfying high-linearity and the design specification. In desigining the OP-AMP, using a structure that accepts some distortion we could reduce the chip area, and reducing the DC path using a new biascircuit gave us better power performance. The designed.SIGMA..DELTA. D/A converter post-processing filter does its smoothering operations and reconstructs the data without reducing the performance of the system.

  • PDF

변압기를 사용한 정현파 입력전류 Multi-Level Converter (A Sinusoidal Input Current Multi-Level Converter Using Transformer)

  • 김천식;이현우;서기영;전중함;한호동;박우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.250-253
    • /
    • 2001
  • This paper is proposed a sinusoidal input voltage Multi-level AC-DC Converter using transformer. In this paper Multi-level PWM Control converter which controls input current by combining buck Converters together to improve input current characteristic, and confirmed its validity throughout simulation and experiment. This method, which is multiplying and duplicating output of converter of equal capacity, is able to control unit power factor of input current, reduce the problem caused by high frequency switching, and apply to high power converter because filter is not necessary.

  • PDF

Cascaded Boost Multilevel Converter for Distributed Generation Systems

  • Kim, Ki-Mok;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.70-71
    • /
    • 2017
  • This paper presents a new cascaded boost multilevel converter topology for distributed generation (DG) systems. Most of DG systems, such as photovoltaic (PV), wind turbine and fuel cells, normally require the complex structure power converters, which makes the system expensive, complex and hard to control. However, the proposed converter topology can generate a much higher output voltage just by using the standard low-voltage switch devices and low voltage DC-sources in a simplified structure, also enhancing the reliability of the switch devices. Simulation and experimental results with a 1.2kW system are presented to validate the proposed topology and control method.

  • PDF

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

마이크로프로세서에 의한 디지탈 제어방식에서 직류/교류 전력변환장치 전류제어 성능의 최적화 (The Optimization of Current Control in DC/AC Power Converters under Digital Control with Microprocessor)

  • 우명호;목형수;정승기
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.61-69
    • /
    • 1998
  • 본 논문은 예측전류제어기의 연산시간에 의한 전압형 PWM 인버터의 과도상태 특성 저하를 개선하기 위한 부분보상 예측전류 제어기에 관한 연구로서, 먼저 부분보상 예측전류제어 시스템에 대한 해석을 통해 과도상태시 정정시간을 최소화할 수 있는 가중치를 구하였다. 또한 부분보상 예측전류제어에 의한 PWM 인버터의 출력전압 포화 경계조건을 유도하여 포화현상이 예측전류제어기의 과도응답 특성에 미치는 영향을 살펴보았다. 끝으로 부분보상 예측전류제어기를 능동전력필터에 적용하여 가중치에 따른 과도응답 특성을 실제전류와 샘플링전류를 중심으로 고찰하였다.

고조파 규제값에 적합한 에어컨 전원장치 (Air-Conditioner Power Source Device to Meet the Harmonic Guide Lines)

  • 문상필;박영조;서기영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권10호
    • /
    • pp.581-586
    • /
    • 2002
  • To improve the current waveform of diode rectifiers, we propose a new operating principle for the voltage-doubler diode rectifiers. In the conventional voltage-doubler rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses smaller ones and a small reactor not to boost the output voltage but improve the input current waveform. A circuit design method is shown by experimentation and confirmed simulation. The experimental results of the proposed diode rectifier satisfies the harmonic guide lines. A high input power factor of 97(%) and an efficiency of 98[%] are also obtained. The new rectifier with no controlled switches meet the harmonic guide lines, resulting in a simple, reliable and low-cost at-to dc converters in comparison with the boost-type current-improving circuits. This paper proposes a nonlinear impedance circuit composed by diodes and inductors or capacitors. This circuit needs no control circuits and switches, and the impedance value is changed by the polarity of current or voltage. And this paper presents one of these applications to improve the input current of capacitor input diode rectifiers. The rectifier using the nonlinear impedance circuit is constructed with four diodes and four capacitors in addition to the conventional rectifiers, that is, it has eight diodes and five capacitors, including a DC link capacitor. It makes harmonic components of the input current reduction and the power factor improvement. Half pulse-width modulated (HPWM) inverter was explained compared with conventional pulse width modulated(PWM) inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting.