• Title/Summary/Keyword: PWM AC/AC converter

Search Result 371, Processing Time 0.022 seconds

A New current Controller implemented in a-b-c frame for AC-DC converter (a-b-c frame에서 구현한 AC-DCconverter 전류제어기)

  • 노의철
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.282-285
    • /
    • 2000
  • A new current controller implemented in a-b-c frame for AC-DC converter is proposed. The proposed MTPWM(Modified Trapezoidal PWM) Which is quite suitable for three phase AC-DC converter. It is known that MTPWM has good harmonics characteristics for high modulation index. It is very simple and requires no transformation in it. The results of computer simulation are shown for the validity of proosal.

  • PDF

A Novel Variable-Speed Renewable-Energy Generation System of Induction Generator and PWM Converter for Small-Scale Hybrid Power Applications

  • Ahmed, Tarek;Nishida, Katsumi;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1339-1342
    • /
    • 2005
  • This paper presents a simple AC-DC power conditioner for a squirell-cage induction generator(IG) operating under variable shaft speeds. The necessary reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM power converter size. A simple control compensating for changes in the electrical loads as well as the variation in speed was developed to regulate the voltages of the IG system by controlling the rotor flux through its reactive and active currents control implementation. This proposed power conditioning scheme can be used efficiently as a wind power generation system where the output voltage of the IG is maintained constant voltage despite the variable frequency and the DC bus voltage of the PWM converter can be used for either DC applications such as battery charging or AC power applications with 60/50 Hz by connecting a stand alone inverter. The experimental and simulated operating performance results of a 5 kW IG scheme at various speeds and leads are presented.

  • PDF

Reactive Power Compensation Using Switching Cell Structured Direct PWM AC-AC Converter (스위칭 셀 PWM AC-AC 컨버터를 이용한 단상 무효전력 보상장치)

  • Kim, Sanghun;Kim, Heung-Geun;Cha, Honnyong
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.513-514
    • /
    • 2016
  • 본 논문에서는 스위칭 셀 구조의 직접형 PWM ac-ac 컨버터를 이용한 새로운 단상 무효전력 보상 장치를 제안한다. 제안한 보상기는 최근에 개발된 가변 임피던스 개념을 이용한 무효전력 보상기에서 발전된 형태이다. 기존 보상기에는 시스템 신뢰성에 심각한 악영향을 주는 커뮤테이션 문제가 존재하는데 제안한 보상기에서는 스위칭셀 구조와 결합인덕터로 구성된 ac-ac 컨버터를 사용하여서 커뮤테이션 문제를 해결하였다. 이로인해 기존 시스템에 비해 스위칭 신호 구현이 매우 간편하고 RC 스너버가 필요하지 않으며 결과적으로 매우 신뢰성이 높은 시스템을 구현할 수 있다. 간략화 된 단상시스템을 구축하여 실험을 통해 성능을 검증하였다.

  • PDF

Voltage Sensorless Control for Three-Phase Voltage Source PWM Converter (3상 전압형 PWM 컨버터의 전압 센서리스 제어)

  • Heo, Tae-Won;Cho, Kwang-Seung;Kim, Young-Bin;Seo, Jung-Ki;Cho, Yong-Gil;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2656-2658
    • /
    • 1999
  • This paper presents a control scheme for a three-phase PWM converter system without any voltage sensors. Two input currents and one load current are measured. In a general PWM converter system, the required AC input and DC output voltage values in order to control the converter are estimated using the differential equations of the converter from the measured input currents and load current values in the switch modes of the converter circuit. The PI controller is used as DC voltage controller and sinusoidal tracking controller which tracks directly AC input current is used as input current controller. The Proposed method is verified by simulations. This paper describes the estimation method and configuration of the controller, and discusses steady state and transient performances of the converter

  • PDF

Real-Time Estimation of the Boost Inductance in a Single-phase AC/DC parallel PWM converter for High-speed EMU (동력분산형 고속철도의 단상 병렬 AC/DC PWM 컨버터를 위한 승압형 인덕턴스의 실시간 추정)

  • Jung, Hwan-Jin;Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.259-264
    • /
    • 2009
  • This paper proposes a real-time estimation of the boost inductance in a single-phase AC/DC parallel PWM converter for high-speed EMU. The estimation procedure of the boost inductance is only based on the variation of input current and the input AC voltage measurement. The estimated boost inductance is optimized by the least square method. This estimation technique can improve the performance of current controller and reduce the harmonics of the input current in the feed-forward controller. The validity of proposed technique is verified through the MATLAB SIMULINK simulation results.

  • PDF

Design and Simulation of High Efficiency PWM Modulation Method for Three-phase Matrix Converter (3상 매트릭스 컨버터의 고효율 변조방법 설계 및 시뮬레이션)

  • Lim, Hyun-Joo;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • A matrix converter is used for converting AC/AC power directly. In order to generate sinusoidal input/output waveform in matrix converter, it uses nine bidirectional switches and PWM modulation. This paper presents an analytical averaged loss model of matrix converter with DDPWM(direct duty ratio PWM) and proposes a new switching method for reducing switching losses. A Mathematical loss models with average magnitude of voltage/current are classed as conduction and switching loss. The proposed switching pattern is improved with existing DDPWM. To prove improved efficiency with proposed DDPWM, this paper compares losses between suggested switching pattern and conventional switching pattern using mathematical and simulation method. Each loss types are influenced by environmental factors such as temperature, switching frequency, output current and modulation method.

Analysis and Compensation of Current Sampling Error in Discontinuous PWM Inverter for AC Drive (교류 전동기 구동용 불연속 PWM 인버터의 전류 샘플링 오차 해석 및 보상)

  • Song, Seung-Ho;Son, Yo-Chan;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.517-522
    • /
    • 1999
  • This paper addresses the issue of current sampling in a high performance AC drive system fed by a discontinuous PWM inverter. The effect of the sampling error due to the measurement delay produced by an input stage low pass filter and an A/D converter is described in the case of discontinuous PWM. To compensate for the sampling error, a method to estimate the delay time of the whole measurement system based on the measured current is proposed and its effectiveness is verified by experimental results. The proposed algorithm can automatically estimate the system delay introduced by the low pass filter and the A/D converter at the commissioning stage. By delaying the current sampling by the estimated value, experimental results indicate that more than 50% reduction of current ripple can be achieved.

  • PDF

Development of Single Phase PWM Converter for AC Traction System (교류 철도 차량 시스템용 단상 PWM Converter 개발)

  • Min, S.S.;Cha, J.D.;Hong, S.W.;Kim, S.W.;Park, Y.C.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.505-508
    • /
    • 1994
  • This paper describes an implementation of a single phase PWM ac/dc converter whose control scheme can be directly applied to the rectification of ac traction system. Power circuit using self-commutated switching devices(GTO) provides input power factor correction with dc voltage regulation. Effective compensation of load variations and line disturbance can be accomplished by real time instantaneous control of ac input current and dc link voltage using 32 bit floating point DSP. Parallel operation of two converters reduces the input line current ripple. Experimental results of the two parallel converter system are shown in the 20KW range for the verification of the system.

  • PDF

Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters

  • Kim, Soo-Cheol;Nguyen, Thanh Hai;Lee, Dong-Choon;Lee, Kyo-Beum;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.695-703
    • /
    • 2014
  • In this paper, a fault detection scheme for DC-link voltage sensor and its fault tolerant control strategy for three-phase AC/DC/AC PWM converters are proposed, where the Luenberger observer is applied to estimate the DC-link voltage. The Luenberger observer is based on a converter model, which is derived from the voltage equations of a grid-side converter and the power balance on a DC link. A fault of the voltage sensor is detected by comparing the measured value of the DC-link voltage with the estimated one. When a sensor fault is detected, a fault tolerant control strategy is performed, where the estimated DC-link voltage is used for the feedback control. The estimation error from the observer is about 1.5 V, which is sufficiently accurate for feedback control. In addition, it is shown that the observer performance is robust to parameter variations of the converter. The validity of the proposed method has been verified by simulation and experimental results.

A study of residential solar airconditioning system using bidirectional PWM converter (양방향성 PWM컨버터를 이용한 가정용 태양광 에어컨 시스템에 관한 연구)

  • 유권종;송진수;황인호;김홍성;고재석;최규하;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.358-364
    • /
    • 1996
  • Recently, much power demand from domestic power consumer is weakening the allowable power reserve margin in summer, especially at midday for one day due to a steep increase of air cooling loads such as air conditioner. Therefore solar airconditioning system can'be considered as one of the best remedies to meet the increase of peak power. Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can derate the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problem in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. As results, obtained are the characteristics of the PWM converter such as low distorted current waveform, high power factor and bidirectional power control. And also the stability of proposed system is verified by examining the dynamics of step load change and power reversal testing. (author). refs., figs., tabs.

  • PDF