• 제목/요약/키워드: PVC-membrane

검색결과 169건 처리시간 0.032초

Performance and characterization of PEG400 modified PVC ultrafiltration membrane

  • Aryanti, P.T.P.;Yustiana, R.;Purnama, R.E.D.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.379-392
    • /
    • 2015
  • Polyvinyl chloride (PVC) ultrafiltration membrane was prepared by blending 12 wt.% of PVC in N, N-dimethylacetimide (DMAc) with polyethylene glycol 400 (PEG400) as an additive. The influence of PEG400 concentration on the PVC membrane morphology, permeability, fouling and rejection were investigated. Fouling and rejection of the PVC membrane were characterized by dextran T-100 filtration. The results showed that membrane water flux was increased up to $682Lm^{-2}h^{-1}$ when 28 wt.% of PEG400 was added into the PVC membrane solution. The best membrane performance with a low fouling and a high selectivity was achieved by adding 12 wt.% concentration of PEG400, which resulted in 90% rejection of dextran and 90% of flux recovery ratio. At further addition of PEG400 concentration, irreversible fouling was starting to increase. A 90% of irreversible fouling was formed in the PVC membrane when more than 22 wt.% of PEG400 is added.

Cost-effective polyvinylchloride-based adsorbing membrane for cationic dye removal

  • Namvar-Mahboub, Mahdieh;Jafari, Zahra;Khojasteh, Yasaman
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.131-139
    • /
    • 2020
  • The current study focused on the preparation of low-cost PVC-based adsorbing membrane. Metakaolin, as available adsorbent, was embedded into the PVC matrix via solution blending method. The as-prepared PVC/metakaolin mixed matrix membranes were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, atomic force microscopy (AFM), pure water permeability and contact angle measurements. The results confirmed the improvement of PWP and hydrophilicity due to the presence of metakaolin in the PVC matrix. Additionally the structure of PVC membrane was changed due to the incorporation of metakaolin in the polymer matrix. The static adsorption capacity of all samples was determined through dye removal. The effect of metakaolin dosage (0-7%) and pH (4, 8, 12) on dye adsorption capacity was investigated. The results depicted that the highest adsorption capacity was achieved at pH of 4 for all samples. Additionally, adsorption data were fitted on Langmuir, Freundlich, and Temkin models to determine the appropriate governing isotherm model. Finally, the dynamic adsorption capacity of the optimum PVC/metakaolin membrane was studied using dead-end filtration cell. The dye removal efficiency was determined for pure PVC and PVC/metakaolin membrane. The results demonstrated that PVC/metakaolin mixed matrix membrane had a high adsorption capacity for dye removal from aqueous solution.

In-situ modification of PVC UF membrane by SiO2 sol in the coagulation bath during NIPS process

  • Cheng, Liang;Xu, Zhen-Liang;Yang, Hu;Wei, Yong-Min
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.317-325
    • /
    • 2018
  • Polyvinyl chloride (PVC) ultrafiltration (UF) membrane was modified by silica sol in the coagulation bath during non-solvent induced phase separation (NIPS) process. The effects of silica sol concentrations on the morphology, surface property, mechanical strength and separation property of PVC UF membranes were systematically investigated. PVC membranes were characterized by Fourier transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), contact angle goniometry and tensile strength measurement. The results showed that silica had been successfully assembled on the surface of PVC UF membrane. With the increase of silica sol concentration in the coagulation bath, the morphologies of PVC UF membranes changed from cavity structure to finger-like pore structure and asymmetric cross-section structure. The hydrophilicity and permeability of PVC UF membranes were further evaluated. When silica sol concentration was 20 wt.%, the modified PVC membrane exhibited the highest hydrophilicity with a static contact angle of $36.5^{\circ}$ and permeability of $91.8(L{\cdot}m^{-2}{\cdot}h^{-1})$. The structure of self-assemble silica had significant impact on the surface property, morphology, mechanical strength and resultant separation performance of the PVC membranes.

초음파 표면개질에 의한 CDI 전극용 술폰화 염화비닐(PVC) 멤브레인의 제조 및 특성 (Preparation and Properties of Sulfonated Polyvinylchloride (PVC) Membrane for Capacitive Deionization Electrode by Ultra Sonication Modification)

  • 황치원;오창민;황택성
    • 접착 및 계면
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2014
  • 이온 교환막은 전기투석, 확산투석, Redox flow 전지, 연료전지 등 다양하고 넓은 분야에서 사용되고 있다. 초음파를 이용하여 만들어진 PVC 양이온 교환막을 시간을 변화시켜 가면서 술폰화 반응에 의해 제조하였다. 술폰화제로 황산을 사용하였으며, 술폰화 PVC 양이온 교환막의 기본구조와 특성을 FT-IR, EDX, Water uptake, 이온교환용량(IEC), 전기저항(ER), 전도도, 이온수송수 및 표면 morphology를 SEM 분석하였다. FT-IR 스펙트럼 분석결과 술폰화 PVC 양이온 교환막에 술폰산기가 도입되었음을 확인하였으며 멤브레인의 Water uptake, IEC, 전기 저항 및 ion transport number의 최대값은 각각 40.2%, 0.87 meq/g, $35.2{\Omega}{\cdot}cm^2$ 및 0.88이었다.

수면전개 복합막의 기체투과 특성에 관한 연구 (Gas Permeation Characteristics of Water-Casting Composite Membrane)

  • Nam, Suk-Tae
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1992년도 추계 총회 및 학술발표회
    • /
    • pp.49-52
    • /
    • 1992
  • 본 연구에서는 기체분리용 고분자 분리막을 박막화하기 위하여 기체의 선택도와 투과도가 서로 상이한 celluloseacetate(CA), polyvinylchloride(PVC) 및 polystyrene(PS) 등의 고분자용액을 사용하여 수면전개법에 수면 전개기구와 박막의 구조적 특성을 연구하였고, 또한 기체 분리막으로서의 이 수면전개막을 개발하기 위하여 CA, PVC, PS 단일 적층막, CA-PVC 복합적 층막, PVC/PS 혼합적층막의 형태로 제막하여 기체분리효과를 검토하였다.

  • PDF

Reactive modification of PVC membranes for the improved performance

  • Jhaveri, Jainesh H.;Patel, Chetan M.;Murthy, Z.V.P.
    • Membrane and Water Treatment
    • /
    • 제9권6호
    • /
    • pp.385-392
    • /
    • 2018
  • Poly vinyl chloride (PVC) was chemically modified, and used for ultrafiltration to analyze the performance. Non-solvent induced phase separation (NIPS) method was used to prepare membranes. The neat PVC membrane was casted and used as a control membrane. Modified membrane was prepared by reacting PVC with ethanolamine (EA) in the casting solution (labeled as CM-PVC). Pure water permeability (PWP) was evaluated by measuring pure water flux. Humic acid was used as model foulant solute to analyze flux and rejection ability of membranes. Flux and rejection data of neat and modified membranes were compared to prove the improvement in the filtration performance. The experimental results showed that for PVC and CM-PVC, PWP was calculated to be ~64 and ${\sim}143L/m^2{\cdot}h$, respectively, and the rejection of humic acid was found to be 98% and 100%, respectively. TGA was carried out to analyze the effect of chemical modification on the thermal stability of polymer. FT-IR analysis was another characterization technique used for the comparative study.

PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가 (Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters)

  • 변성욱;최상준
    • 한국산업보건학회지
    • /
    • 제26권1호
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

Studies of Polymer Matrix Effect for Coextraction Type Anion-Selective Optode and Determination of Thiocyanate in Human Saliva

  • Hong, Young-Ki;Cha, Geun-Sig;Shin, Doo-Soon;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권10호
    • /
    • pp.836-841
    • /
    • 1994
  • The polymer matrix effect on the selectivity, response rate and reproducibility for coextraction type anion-selective optode membranes were investigated with DOA-plasticized PVC, PVC/hydroxylated PVC, PU/hydroxylated PVC and DOS-plasticized CTA matrices. Optode membranes were prepared with TDMACl and ETH2412 dissolved in one of the four solvent polymeric matrices. The PU/hydroxylated PVC and PVC-based membranes have almost the same selectivity coefficients, while the CTA-based membrane is more selective toward lipophilic anions. The membrane with PU/hydroxylated PVC adhered strongly to a glass surface, and showed highly reproducible and relatively rapid response. Very poor adhesion of PVC/hydroxylated PVC and CTA-based membranes limited the usability of those membranes as sensor components. Based on these results, and considering the biocompatibility for clinical samples, the optode made with PU/hydroxylated PVC was applied to determine the thiocyanate ion in human saliva. The results obtained with this simple device were comparable to those with rather complicated ISE methods.

Lead-selective PVC Membrane Electordes Based on Bis(Crown ether)s

  • 오금철;강은철;정규성;팽기정
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권5호
    • /
    • pp.556-558
    • /
    • 1999
  • Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and alkaline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric liquid membrane based on trans-1 8-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10-6 and 10-2 M, Pb2+), excellent detection limit (less than 10-6 M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.