• 제목/요약/키워드: PVA solution

검색결과 228건 처리시간 0.047초

Fixation of $\gamma$-Radionuclides by the PVA-PMAA System

  • Won, Hui-Jun;Ahn, Byung-Gil;Jung, Chong-Hun;Kim, Gye-Nam;Oh, Won-Zin
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.205-213
    • /
    • 2000
  • A series of laboratory experiments was conducted to investigate the fixation characteristics of poly(vinylalcohol)-poly(methacrylic acid)(PVA-PMAA) mixed solution on the soluble ${\gamma}$- radionuclides. Using the potentiometric titration technique, it was found out that the PVA and PMAA in a solution form intermacromolecular complex. The mobilized portion of each radionuclide by water from sand surface treated with a fixative was measured by ${\gamma}$-ray spectroscopy. The mobilized portion of minor radionuclides such as 241Am, 154Eu, 155Eu and 144Ce were higher than those of 134Cs and 137Cs. The capability of PVA-PMAA system was better among the candidate solutions for the fixation of total ${\gamma}$-radioactivity. 134,137Cs which is composed of more than 85 % of total ${\gamma}$-radioactivity could be fixed effectively by the PVA-PMAA solution.

  • PDF

고검화도의 폴리(비닐 알코올)/디메틸설폭사이드 용액에서의 점성도 특성과 탐침입자의 확산 (Probe Diffusion and Viscosity Properties in Dimethyl Sulfoxide Solution of Poly(vinyl alcohol) with High Degree of Hydrolysis)

  • 엄효상;박일현
    • 폴리머
    • /
    • 제34권5호
    • /
    • pp.415-423
    • /
    • 2010
  • 고검화도(98%이상)의 폴리(비닐 알코올)(PVA)를 디메틸설폭사이드(DMSO) 용매에 녹인 뒤 PVA 준희박 용액 대에서 농도 $C{\simeq}0.14\;g/mL$까지 점성도를 측정하였으며, 이 시스템을 매트릭스로 하여 폴리스티렌(PS) 라텍스 입자의 확산운동 지연을 동적 광산란법으로 조사하였다. PVA/DMSO계의 점성도를 고유점성도 $[{\eta}]$로 스케일된 환산농도 $C[{\eta}]$에 대하여 도시하였을 때 C$[{\eta}]$ >2에서는 분자량 의존성이 강하게 나타났으며, 그 원인은 PVA 용액 내에 존재하는 불균일 영역때문인 것으로 추정하였다. 그러나 매트릭스 내에서 탐침입자의 확산운동은 모든 측정농도에서 단일모드로 관찰되었고, 용액상 및 용매상에서의 확산계수의 비인 D/Do를 $C[{\eta}]$로 도시할 때 전체 농도 범위에서 분자량 의존성은 전혀 나타나지 않았으나 신장지수함수의 적용 한계는 C$[{\eta}]$ >2.5인 것으로 관찰되었다.

PVA 폴리머를 이용한 니켈 알루미네이트 분말의 합성 및 특성연구 (Characteristics of Nickel Aluminate Ceramics Synthesized by Organic (PVA)-Inorganic Solution Technique)

  • 이상진;김주원
    • 한국세라믹학회지
    • /
    • 제40권7호
    • /
    • pp.690-695
    • /
    • 2003
  • 고순도의 세라믹분말을 합성할 수 있는 용액 화학적 합성방법의 하나로서, 폴리머를 이용한 분말합성방법이 개발되었다. 본 연구에서는 PVA(Polyvinyl Alcohol)을 이용하여 니켈 알루미네이트(NiAl$_2$O$_4$) 분말을 합성하였다. PVA 첨가에 의하여 용액내의 금속 양이온들의 분산을 극대화하며, 순수한 니켈 알루미네이트를 얻기 위한 결정화 온도를 낮출 수 있었다. PVA 폴리머를 이용함으로써 분쇄가 용이한 부드러운 팽창성 분말을 얻을 수 있었으며, 볼 밀링에 의하여 약 300 nm의 크기를 보이는 좁은 입도의 미세한 분말이 얻어졌다 1$600^{\circ}C$, 1시간 소결에 의하여 4.35 g/㎤의 밀도를 보이는 치밀한 니켈 알루미네이트를 얻을 수 있었으며, 측정된 경도, 곡강도, 파괴인성 및 열팽창계수 값은 각각 14.2 ㎬, 304 ㎫, 4.8 ㎫.m$^{1}$2/과 9.8$\times$$10^{-6}$/$^{\circ}C$를 보였다.

폴리비닐알코올/디메틸술폭시드/물/붕산 용액계에 있어서 물함량이 유변학적 특성에 미치는 영향 (Effect of Water Level on the Rheological Properties of Polyvinyl Alcohol/Dimethyl Sulfoxide/Water/Boric Acid Solution Systems)

  • 김병철;김승규
    • 유변학
    • /
    • 제11권1호
    • /
    • pp.28-33
    • /
    • 1999
  • 붕산은 폴리비닐알코올(PVA)의 히드록시기간의 가교를 형성할 수 있기 때문에 PVA용액내에 가입되면 용액의 유변학적 특성에 큰 영향을 미친다. 본 연구에서는 양이온이 존재하지 않는 경우 PVA/디메틸술폭시드(DMSO)/물/붕산계에 있어서 물의 함량이 유변학적 특성에 미치는 영향을 조사하였다. PVA/DMSO/물계에 붕산을 1 wt.% 첨가할 경우 물 함량이 증가할 수록 점도가 급속히 감소하였다. PVA/DMSO계에 1 wt.%의 붕산이 가입된 경우 양이온이 없어도 강한 가교구조를 형성하여 탄성겔의 점탄성특성을 나타낸 반면 PVA/물계에 1 wt.%의 붕산이 가입된 경우 전형적인 점성물질의 특성을 나타냈다. 순수한 DMSO나 혼합용매중 DMSO의 함량이 높으면 양이온의 존재없이도 붕산첨가에 의해 가교구조를 형성하여 급격한 점도변화를 나타냈으나 물 함량이 풍부한 계에서는 붕산의 첨가에 따른 점도의 변화가 미약하였으며 순수한 물을 용매로 사용한 경우 붕산첨가의 영향이 거의 없었다. 저장탄성률도 PVA/DMSO계의 경우가 가장 높은 값을 보였고 혼합용매계에는 물함량이 증가할 수록 감소하였다.

  • PDF

IPA 수용액으로부터 수분제거를 위한 침지형 모듈 제조와 투과증발 특성 (Pervaporation Performance of Submerged Type Membrane for the Separation of Water from Aqueous Isopropanol Solution)

  • 우승문;박윤환;남상용
    • 멤브레인
    • /
    • 제28권4호
    • /
    • pp.279-285
    • /
    • 2018
  • 이소프로필알코올/물 혼합물은 가교된 폴리비닐알코올 복합막을 이용하여 투과특성평을 알아보았다. 검화도가 다른 3종 PVA를 이용하여 고분자의 농도와 GA 농도에 따라서 투과특성을 확인하였다. 복합막은 PVA 용액을 PAN 지지체 위에 캐스팅한 후, 열가교를 통해 제조하였다. PVA 농도가 증가할수록 투과도는 감소하지만 선택도는 증가하는 것을 확인하였다. PVA-3이 7 wt% 농도로 코팅된 복합막에서 $209g/m^2h$의 투과도를 가지고, 100 이상의 선택도를 가지는 것을 확인하였다. 침지형 분리막을 제조하여 feed tank 온도와 feed 용액의 IPA 농도에 따라서 투과실험을 확인하였다. 또한 IPA 수용액에 농축실험을 지속적으로 한 결과, 60시간 후에 IPA의 농도가 99%까지 증가하는 것을 확인하였다.

PVA 중합도가 고상-액상 혼합 방식에 의한 YAG:Ce3+ 형광체 분말 합성에 미치는 영향 (Effect of PVA Polymerization on Synthesis of YAG:Ce3+ Phosphor Powders Prepared by a Solid-liquid Hybrid Route)

  • 김아름;이상진
    • 한국세라믹학회지
    • /
    • 제51권5호
    • /
    • pp.424-429
    • /
    • 2014
  • YAG:$Ce^{3+}$ phosphor powders were synthesized using $Al(OH)_3$ seeds by means of a PVA-polymer-solution route. Various types of PVA with different molecular weights (different polymerization) were used. All dried precursor gels were calcined at $500^{\circ}C$ and then heated at $1500^{\circ}C$ in a mix of nitrogen and hydrogen gases. The final powders were characterized via XRD, SEM, PSA, PL, and PKG analyses. The phosphor properties and morphologies of the synthesized powders were dependent on the PVA type. As the molecular weight of the PVA was increased, the particle size gradually decreased with agglomeration, and the luminous intensity of the phosphor increased. However, the phosphor powder prepared from the PVA exhibiting very high molecular weight, showed a 531 nm (blue) shift from the 541 nm (yellow) wavelength of the YAG:$Ce^{3+}$ phosphor. Finally, the synthesized YAG:$Ce^{3+}$ phosphor powder prepared from the PVA with 89,000 - 98,000 molecular weight showed phosphor properties similar to those of a commercial phosphor powder, but without a post-treatment process.

Effect of Crosslinking on Release of Model Drug from Electrospun Poly(vinyl alcohol) Fiber Mats

  • Taepaiboon, Pattama;Rungsardthong, Uracha;Supaphol, Pitt
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.258-258
    • /
    • 2006
  • Electrospun fibers of poly(vinyl alcohol) (PVA) were successfully prepared and applied as drug carriers for transdermal drug delivery system. Sodium Salicylate (SS) was the model drug and it was incorporated in the PVA fibers by adding 20 % of SS in a PVA solution prior to electrospinning. Electrospinning of SS-containing PVA solution resulted in the formation of beaded fibers. In order to control the rate of SS release and decrease water solubility of PVA, the SS-loaded electrospun PVA mat was cross-linked by either glutaraldehyde or glyoxal vapor. The morphology, thermal behavior, swelling behavior, release characteristic, kinetics of drug release and also toxicity of the cross-linked sample were investigated.

  • PDF

전자빔 조사를 이용한 고분자량 혼성배열 폴리(비닐 알코올) 수화젤의 제조 (Preparation of High Molecular Weight Atactic Poly(vinyl alcohol) Hydrogel by Electron Beam Irradiation Technique)

  • 김경식;이영재;류원석;노석균
    • 폴리머
    • /
    • 제32권6호
    • /
    • pp.587-592
    • /
    • 2008
  • 고분자량 폴리 (비닐 알코올) (poly(vinyl alcohol), PVA)에 전지빔 (electron beam, EB)을 조사하여 상처치료용 드레싱으로 응용이 기대되는 수화젤을 성공적으로 제조하였다. 다양한 겔화율, 물에서의 팽윤도, 겔강도, 및 신도를 가지는 수화젤을 제조하기 위해 수평균 중합도($P_n$)가 1700과 4000인 두 종류의 PVA를 이용하였으며, PVA 수용액 농도와 EB 조사선량은 5$\sim$20%와 30$\sim$100 kGy의 범위로 각각 조절되었다. 제조된 PVA 수화젤의 겔화율과 겔강도는 PVA의 분자량과 수용액의 농도 및 EB 조사선량이 증가함에 따라 증가하였으나, 반면에, PVA 수화젤의 팽윤도와 신도는 감소하였다. PVA 수화젤의 가교밀도에 따른 열적특성과 결정성의 변화는 differential scanning calorimetry와 X-ray diffraction을 이용하여 분석되었다.

추출제 D2EHPA와 TOPO를 PVA에 고정화한 PVA-D2EHPA/TOPO 비드의 제조와 수중의 구리 이온 제거 특성 (Preparation of PVA-D2EHPA/TOPO Beads by Immobilizing Extractants D2EHPA and TOPO with PVA and Removal Characteristics of Copper Ions from Aqueous Solution)

  • 감상규;박정민;이민규
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1583-1591
    • /
    • 2014
  • PVA-D2EHPA/TOPO beads containing two extractants, di-(2-ethylhexyl) phosphoric acid (D2EHPA) and trioctylphoshine oxide (TOPO) were prepared for the removal of copper ions from aqueous solution. The prepared PVA-D2EHPA/TOPO beads were characterized by SEM and FT-IR. The removal characteristics of copper ions by PVA-D2EHPA/TOPO beads was investigated using batch and continuous systems. In batch experiments, the maximum removal capacity calculated from Langmuir isotherm model was 18.6 mg/g and the optimal pH was in the range of 4.5~6. The continuous experiments showed that the removal capacity of copper ions increased with increasing inlet copper ion concentrations and bed heights, but decreased with increasing inlet flow rates.