• Title/Summary/Keyword: PV simulator

Search Result 87, Processing Time 0.047 seconds

A Study on the Customer Voltage Characteristic Based on the Test Devices for PV Systems (태양광전원 계통연계 시험장치에 의한 수용가전압 특성에 관한 연구)

  • Park, Hyeon-Seok;Son, Joon-Ho;Ji, Seong-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4529-4536
    • /
    • 2010
  • This paper develops an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV systems simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and load factor. This paper also proposes a new calculation algorithm for voltage profile to make a comparison between calculation values and test device values. The results show that the test results for the normal operation characteristics of PV systems is very practical and effective.

Mathematical Consideration on PV Cell Modeling (PV cell modeling의 수학적 고찰)

  • Park, Hyeonah;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2014
  • PV cell modeling is necessary both for software and hardware simulators in analyzing and testing the performance of PV generation systems. Unique I-V curve of a PV cell identifies its own characteristics by electrical equivalent model that is composed of diode constants ($I_o$, $v_t$), photo-generated current ($I_{ph}$), series resistance ($R_s$), and shunt resistance ($R_{sh}$). Photo-generated current can be easily estimated since it is proportional to irradiation level. However, other electrical parameters should be solved from the manufacturer's data sheet that is consisted with three remarkable operating points such as open circuit voltage ($V_{oc}$), short circuit current ($I_{sc}$), and maximum power voltage/current ($V_{MPP}/I_{MPP}$). This paper explains and analyzes mathematical process of a novel PV cell modeling algorithm that was proposed by the authors with the name of "K-algorithm".

A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS) (RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

Solar Comparative Analysis of Various MPPT Algorithms (태양광 최대전력추종 제어알고리즘 성능 비교 분석)

  • Shim, Jae-Hwe;Kang, San;Kim, Shin-Ah;Hong, Ki-Nam;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.77-78
    • /
    • 2010
  • As the maximum power operating point(MPOP) of photovoltaic(PV) power systems alters with changing atmospheric conditions, the efficiency of maximum power point tracking(MPPT) is important in PV power systems. Moreover, grid-connected PV system occurs some problems such as voltage inequality and harmonics. Therefore, this paper presents the results of a grid-connected PV system modeling by PSIM simulator and investigates the influence on the grid-connected PV system from aspect of power quality, i.e. voltage drop. This paper includes four MPPT algorithms; Perturbation & Observation(P&O), Improved P&O, Increment Conductance(Incond), Hysterisis simulated with irradiation changing.

  • PDF

A New PSIM Model for PV Panels Employing Datasheet-based Parameter Tuning (데이터시트 기반의 새로운 PSIM 태양광 모델)

  • Park, Jun-Young;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.498-508
    • /
    • 2015
  • In the simulation of photovoltaic (PV) power conditioning systems, PSIM is a widely accepted circuit simulation platform because of its fast speed and C-code support. PSIM provides two kinds of generic PV panel models: functional model and physical model. Whereas the functional model simulates PV in the standard test condition (STC) only, the physical model can emulate changing PV characteristics under varying temperatures and irradiation conditions and is thus more suitable for system simulation. However, the physical model requires complicated parameters from users, and thus it is prone to errors and is difficult to use. In this study, a new PSIM model for PV is presented to solve these problems. The proposed model utilizes manufacturers' datasheet values specified under STC only and excludes user-defined information from input parameters. To achieve good accuracy even in varying environmental conditions, single-diode model parameters are successively tuned to a time-varying virtual datasheet. Comparison with a conventional physical model shows that the proposed model provides more accurate simulation according to error analysis based on the EN50530 standard.

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF

Implementation of the 50kW Utility Interconnected Photovoltaic System Simulator (50kW급 계통연계형 태양광발전시스템의 시뮬레이터 구현)

  • Jeong, Byeong-Ho;Park, Jeong-Min;Cho, Geum-Bae;Baek, Hyung-Lae;Chung, Soo-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.21-27
    • /
    • 2005
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW middle scale applications installed in Cho-sun University dormitory roof. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination and developed simulation results. The performance of photovoltaic system has been evaluated and analyzed with simulation. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System (계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가)

  • Seol, Jae-Woong;Jang, Jae-Jung;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2193-2194
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System (계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가)

  • Seol, Jae-Woong;Jang, Jae-Jung;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.561-562
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power Quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD) The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF