• 제목/요약/키워드: PV Systems

검색결과 601건 처리시간 0.022초

3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구 (A Study on Performance Analysis of 3kW Grid-Connected PV Systems)

  • 소정훈;최주엽;유권종;정영석;최재호
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.

계통연계 풍력 및 태양광발전시스템 고조파 영향 검토 (Harmonic Impact Studies of Grid-Connected Wind Power and PV Generation Systems)

  • 이상민;정형모;유권종;이강완
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2185-2191
    • /
    • 2009
  • Wind power and photovoltaic(PV) generation systems are the fastest growing sources of renewable energy. The nonlinear devices, such as power electronic converter or inverter, of wind power and PV generation systems are the source of harmonics in power systems. The harmonic-related problems can have significant detrimental effects in the power system, such as capacitor heating, data communication interference, rotating equipment heating, transformer heating, relay misoperation and switchgear failure. There is a greater need for harmonic analysis that can properly maintain the power quality. By measuring harmonics of existing wind power and PV generation systems as harmonics modeling, the studies were made to see the harmonic impact of grid-connected wind power and PV generation systems.

Type-2 Fuzzy Logic Optimum PV/inverter Sizing Ratio for Grid-connected PV Systems: Application to Selected Algerian Locations

  • Makhloufi, S.;Abdessemed, R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.731-741
    • /
    • 2011
  • Conventional methodologies (empirical, analytical, numerical, hybrid, etc.) for sizing photovoltaic (PV) systems cannot be used when the relevant meteorological data are not available. To overcome this situation, modern methods based on artificial intelligence techniques have been developed for sizing the PV systems. In the present study, the optimum PV/inverter sizing ratio for grid-connected PV systems with orientation due south and inclination angles of $45^{\circ}$ and $60^{\circ}$ in selected Algerian locations was determined in terms of total system output using type-2 fuzzy logic. Because measured data for the locations chosen were not available, a year of synthetic hourly meteorological data for each location generated by the PVSYST software was used in the simulation.

PV 시스템에 대한 PSPICE 모델링과 시뮬레이션 (PSPICE Modelling and Simulation about PV System)

  • 백동현;송호빈;정형용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.163-165
    • /
    • 2009
  • Many photovoltaic (PV) systems are being developed and installed. For a PV developer, simulations are required before the experimental testing. However, most simulation tools do not offer data libraries for PV systems, so that some Institutes who try to use such software will be in difficulty. In this paper, simulations of performance and stability have been carried out using the software PSPICE. In this paper, the modelling of solar cell arrays, photovoltaic modules, PV generators, batteries and drive systems is carried out based on mathematical equivalence circuits and available data, and the models are converted into a data library for PSPICE that is user friendly. System variations can be modeled by simple parameter variation. To verify the accuracy of the simulation library, various models were run and compared to known systems.

  • PDF

A Dynamic Power Distribution Strategy for Large-scale Cascaded Photovoltaic Systems

  • Wang, Kangan;Wu, Xiaojie;Deng, Fujin;Liu, Feng
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1317-1326
    • /
    • 2017
  • The cascaded H-bridge (CHB) multilevel converter is a promising topology for large-scale photovoltaic (PV) systems. The output voltage over-modulation derived by the inter-module active power imbalance is one of the key issues for CHB PV systems. This paper proposed a dynamic power distribution strategy to eliminate the over-modulation in a CHB PV system by suitably redistributing the reactive power among the inverter modules of the CHB PV system. The proposed strategy can effectively extend the operating region of the CHB PV system with a simple control algorithm and easy implementation. Simulation and experimental results carried out on a seven-level CHB grid-connected PV system are shown to validate the proposed strategy.

A Study on the Control Method of Customer Voltage Variation in Distribution System with PV Systems

  • Kim, Byung-ki;Choi, Sung-sik;Wang, Yong-peel;Kim, Eung-sang;Rho, Dae-seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.838-846
    • /
    • 2015
  • This paper deals with the modified modeling of PV system based on the PSCAD/EMTDC and optimal control method of customer voltages in real distribution system interconnected with the photovoltaic (PV) systems. In order to analyze voltage variation characteristics, the specific modeling of PV system which contains the theory of d-q transformation, current-control algorithm and sinusoidal PWM method is being required. However, the conventional modeling of PV system can only perform the modeling of small-scale active power of less than 60 [kW]. Therefore, this paper presents a modified modeling that can perform the large-scale active power of more than 1 [MW]. And also, this paper proposes the optimal operation method of step voltage regulator (SVR) in order to solve the voltage variation problem when the PV systems are interconnected with the distribution feeders. From the simulation results, it is confirmed that this paper is effective tool for voltage analysis in distribution system with PV systems.

태양광발전시스템의 안정성을 고려한 최적 각도 설정에 관한 연구 (A Study on the Optimal Angle Setting Considering the Stability of Photovoltaic Systems)

  • 이여진;한세경;김성열
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.498-504
    • /
    • 2018
  • The conventional photovoltaic(PV) systems are designed the installation angle for maximizing power output by considering a geographical characteristics, weather and climate conditions such as the solar radiation and atmosphere temperature. However, the PV generators must be designed to deal with the extreme situations like typhoons, earthquakes because PV systems are exposed to the ambient conditions and external shock due to condition of PV location. Especially, the wind has relatively higher influence on the design of PV systems, in this paper we proposed the method of determining the optimal nominal dimension of the facilities, which can withstand the maximum wind pressure. By using the proposed method, we determined the optimal installation angle for the aspect stability of PV facilities and amount of power output. Moreover, we analyzed the monthly amount of power for each installation angle of PV systems, and proposed the changing strategy of installation angle by determining the optimal angle to produce maximum power for each period.

Implementation of cost-effective wireless photovoltaic monitoring module at panel level

  • Jeong, Jin-Doo;Han, Jinsoo;Lee, Il-Woo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • 제40권5호
    • /
    • pp.664-676
    • /
    • 2018
  • Given the rapidly increasing market penetration of photovoltaic (PV) systems in many fields, including construction and housing, the effective maintenance of PV systems through remote monitoring at the panel level has attracted attention to quickly detect faults that cause reductions in yearly PV energy production, and which can reduce the whole-life cost. A key point of PV monitoring at the panel level is cost-effectiveness, as the installation of the massive PV panels that comprise PV systems is showing rapid growth in the market. This paper proposes an implementation method that involves the use of a panel-level wireless PV monitoring module (WPMM), and which assesses the cost-effectiveness of this approach. To maximize the cost-effectiveness, the designed WPMM uses a voltage-divider scheme for voltage metering and a shunt-resistor scheme for current metering. In addition, the proposed method offsets the effect of element errors by extracting calibration parameters. Furthermore, a design method is presented for portable and user-friendly PV monitoring, and demonstration results using a commercial 30-kW PV system are described.

컴퓨터기반의 DAS를 적용한 태양광 조명설비의 운용패턴 고찰 (Load Pattern Considerations of The Photovoltaic Lighting System by Using Computer-based Date Acquisition System)

  • 황명근;허창수
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2003
  • 옥외 조명 시스템의 응용으로 두 가지 태양광설비(PV) 조명방식에 저압나트륨 램프(low pressure sodium: LPS)와 무전극 램프(electrodeless lamp)를 부하로 한 조명설비 시스템을 설계·제작·설치하며, 전지 수명을 고려한 감시 목적으로 데이터 수집에 유효한 랩뷰(Labview) 프로그램을 사용하였다. 설치된 PV 시스템에서 태양전지 배열로부터 만들어진 전원 및 그것의 최대 출력에 비교된 에너지 손실을 실험하였고, PV 시스템 개체구성 요소들의 성능을 관찰하였으며, 설치된 PV 조명방식들의 성능을 분석한 후, 태양전지 배열 음량을 줄이는 가능성에 대한 태양광 조명설비 동작특성에 대해 고찰하였다.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.