• Title/Summary/Keyword: PV Curve

Search Result 82, Processing Time 0.029 seconds

Economic Analysis on VLS-PV System from Sunbelt Region (Sunbelt 지역의 태양광발전 경제성분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki;Kim, Seok-Ki;Song, Jin-Soo
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.86-92
    • /
    • 2006
  • This paper analyses the economics of 50kW PV system installed in Tibet and using domestic technology. We show that this system can be expanded to very large-scale photovoltaic power generation [VLS-PV] system successfully. Based on this result, we conduct the economic analysis of 100MW VLS-PV system designed assuming that it will be installed from 2008 to 2017 in Tibet. In this analysis, future price of PV module and system are estimated based on the methodology of experience curve. In 50kW PV system, the generation cost is calculated at 567.2 won/kWh and this is lower than the one of domestic PV system. In future 100MW VLS-PV system. the generation cost is calculated at 305.4 won/kWh by declining system price. If the lifetime and efficiency of the system goes up, due to future technological improvements, the generation cost can be lowered. Moreover, under the environmental and political effect, VLS-PV system can be as competitive as the conventional energy within 20 years.

  • PDF

Design and Application of a Photovoltaic Array Simulator with Partial Shading Capability

  • Beser, Ersoy
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1259-1269
    • /
    • 2019
  • PV system performance is dependent on different irradiations and temperature values in addition to the capability of the employed PV inverter / maximum power point tracker (MPPT) circuit or algorithm. Therefore, it would be appropriate to use a PV simulator capable of producing identical repeatable conditions regardless of the weather to evaluate the performance of inverter / MPPT circuits and algorithms. In accordance with this purpose, a photovoltaic (PV) array simulator is presented in this paper. The simulator is designed to generate current-voltage (I-V) and power-voltage (P-V) curves of a PV panel. Series connected cascaded modules constitute the basic part of the simulator. This feature also allows for the modeling of PV arrays since the number of modules can be increased and high voltage values can be reached with the simulator. In addition, the curves obtained at the simulator output become similar to the actual curves of sample PV panels with an increase in the number of modules. In order to show the validity of the proposed simulator, it was simulated for various situations such as panels under full irradiance and partial shading conditions. After completing simulations, experiments were realized to support the simulation study. Both simulation and experimental results show that the proposed simulator will be very useful for researchers to carry out PV studies under laboratory conditions.

Detection of Aging Modules in Solar String with Jerk Function (Jerk 함수를 적용한 태양광 스트링 내의 노후화 모듈 검출 기법)

  • Son, Han-Byeol;Park, Seong-Mi;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.356-364
    • /
    • 2019
  • In this study, major problems, such as licensing problems due to civil complaints, deterioration of facility period, and damage of modules, are exposed to many problems in domestic businesses. Particularly, the photovoltaic (PV) modules applied to early PV systems have been repaired and replaced over the past two decades, and a new module-based aging detection method is needed to expand the maintenance market and stabilize and repair power supplies. PV modules in a PV system use a string that is configured in series to generate high voltage. However, even if only one module of the solar modules connected in series ages, the power generation efficiency of the aged string is reduced. Therefore, we propose a topology that can measure the instantaneous PV characteristic curve to determine the aging module in the solar string and the aging judgment algorithm using the measured PV characteristic curve.

Improved Global Maximum Power Point Tracking Method Based on Voltage Interval for PV Array under Partially Shaded Conditions

  • Ding, Kun;Wang, Xiang;Zhai, Quan-Xin;Xu, Jun-Wei;Zhang, Jing-Wei;Liu, Hai-Hao
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.722-732
    • /
    • 2014
  • The power-voltage (P-V) curve of photovoltaic (PV) arrays connected in parallel to bypass diodes would have several local maximum power points (LMPP) under partial shading conditions (PSC). Conventional maximum power point tracking (MPPT) methods fail to search for the global maximum power point (MPP) because the searched peak point may remain at the LMPP on the P-V curve under PSC. This study proposes an improved MPPT algorithm to ensure that PV arrays operate at global maximum power point (GMPP) under PSC. The proposed algorithm is based on a critical study and a series of observations of PV characteristics under PSC. Results show the regularity of voltage interval between LMPPs. The algorithm has the advantages of rapidly reaching GMPP, maintaining stability, and recovering GMPP quickly when the operating condition changes. Simulation and experimental results demonstrate the feasibility of the proposed algorithm.

Estimation of Output Power for PV Module with Damaged Bypass Diode using MATLAB (Matlab을 이용한 손상된 바이패스 다이오드가 포함된 PV 모듈의 출력 추정)

  • Shin, Woogyun;Go, Seokhwan;Ju, Youngchul;Chang, Hyosik;Kang, Gihwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.63-71
    • /
    • 2016
  • Installed PV module in field is affected by shading caused by various field environmental factors. Bypass diodes are installed in PV module for preventing a power loss and degradation of PV module by shading. But, Bypass diode is easily damaged by surge voltage and has often initial a defect. This paper propose the electric characteristic variation and the power prediction of PV module with damaged bypass diode. Firstly, the resistance for normal bypass diode and damaged bypass diode of resistance was measured by changing the current. When the current increases, the resistance of normal bypass diode is almost constant but the resistance of damaged bypass diode increases. Next, To estimate power of PV module by damaged bypass diode, the equation for the current is derived using solar cell equivalent circuit. Finally, the derived equation was simulated by using MatLab tools, was verified by comparing experimental data.

The effect of I-V characteristic and hot-spot by solar cell and interconnection circuit in PV module (PV모듈에서 태양전지와 Interconnect회로의 구성이 I-V특성과 Hot Spot에 미치는 영향)

  • Lee, Jin-Seob;Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.241-246
    • /
    • 2008
  • In this paper, we analyze the I-V curve and hot-spot phenomenon caused by solar cells' serial and parallel connected circuit. The mis-match loss of parallel interconnection with low Isc string decrease lower than serially interconnected one and temperature caused by hot-spot does. Also, mis-match loss of parallel interconnection with low Voc string increase more than serially interconnected one. The string having low Voc happened hot-spot phenomenon when open circuit. The bad solar cell in string gives revere bias to good solar cell and make hot-spot phenomenon. If we consider the mis-match loss, when designing PV module and array. the efficiency of PV system might increase.

  • PDF

Improved Photovoltaic MATLAB Modeling Accuracy by Adding Wind Speed Effect

  • An, Dong-Soon;Poudel, Prasis;Bae, Sang-Hyun;Park, Kyung-Woo;Jang, Bongseog
    • Journal of Integrative Natural Science
    • /
    • v.10 no.1
    • /
    • pp.58-63
    • /
    • 2017
  • Photovoltaic (PV) are generally modeled using mathematical equations that describe the PV system behavior. Most of the modeling approach is very simple in terms of that PV module temperature is calculated from nominal constant cell temperature such as ambient temperature and incoming solar irradiance. In this paper, we newly present MATLAB model particularly embedding the effect of wind speed to describe more accurate cell temperature. For analyses and validate purpose of the proposed model, solar power is obtained and compared with and without wind speed from the 50Wp PV module provided by vendor datasheet. In the simulation result, we found that power output of the module is increased to 0.37% in terms of cell temperature a degreed down when we consider the wind speed in the model. This result is well corresponded with the well-known fact that normal PV is 0.4% power changed by cell temperature a degree difference. Therefore it shows that our modeling method with wind speed is more appropriate than the methods without the wind speed effect.

A Novel Grid-Connected PV PCS with New High Efficiency Converter

  • Min, Byung-Duk;Lee, Jong-Pil;Kim, Jong-Hyun;Kim, Tae-Jin;Yoo, Dong-Wook;Ryu, Kang-Ryoul;Kim, Jeong-Joong;Song, Eui-Ho
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.309-316
    • /
    • 2008
  • In this paper, new topology is proposed that can dramatically reduce the converter power rating and increase the efficiency of total PV system. Since the output voltage of PV module has very wide voltage range, in general, the DC/DC converter is used to get constant high DC voltage. According to analysis of PV characteristics, in proposed topology, only 20% power of total PV system power is needed for DC/DC converter. DC/DC converter used in proposed topology has flat efficiency curve at all load range and very high efficiency characteristics. The total system efficiency is the product of that of converter and that of inverter. In proposed topology, because the converter efficiency curve is flat all load range, the total system efficiency at the low power range is dramatically improved. The proposed topology is implemented for 200kW PCS system. This system has only three DC/DC converters with 20kW power rating each other. It is only one-third of total system power. The experiment results show that the proposed topology has good performance.

Stability Analysis of Jeju Power System with Wind Turbine Generators and HVDC (풍력발전설비 및 HVDC가 도입된 제주도 계통에 대한 안정도 해석)

  • Kim, Do-Hyung;Kim, Jae-Eon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1897-1904
    • /
    • 2008
  • In this paper, the method for effective stability analysis of Jeju power system in 2011 is proposed. The stability analysis of Jeju power system was carried out by using proposed method In case of Jeju power system with wind turbine generators or without wind turbine generators, including CSC HVDC or VSC HVDC. The steady-state stability is validated by SCR and ESCR, PV curve, QV curve. And the transient stability is analyzed by CCT(Critical Clearing Time). VSC HVDC has more advantages than CSV HVDC on the stability. Also, Jeju power system without wind turbine generators has more advantages than Jeju power system with Wind Turbine Generators on the stability.

IV Curve Power Calculating Circuit for PV Energy Harvesting for Low Power IoT Sensor Operation (저전력 IoT 센서 구동을 위한 태양광 에너지 하베스팅을 위한 IV Curve 전력 계산회로)

  • Im, Yun Chan;Oh, Dae-Gyun;Kim, Yong Sin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.159-160
    • /
    • 2019
  • 일반적인 FOCV MPPT는 VOC와 VMPP와의 관계인 ${\alpha}$를 외부에서 지정해준다. 하지만 외부환경 (조도나 온도)에 따라서 태양전지의 ${\alpha}$값이 변화할 가능성이 있다. 본 논문에서는 저전력 IoT 센서의 구동을 위한 태양열 에너지 하베스팅을 위해 IV Curve를 이용한 태양전지 전력 계싼회로를 제안한다. IV Curve를 이용한 태양전지 전력을 직접 계산하여 FOCV MPPT를 개선함으로써 보다 높은 효율의 MPPT가 가능하고 외부환경의 변화에도 충분히 Maximum Power Point Tracking이 가능해지게 된다.

  • PDF