• Title/Summary/Keyword: PV Cell

Search Result 502, Processing Time 0.032 seconds

The effect of I-V characteristic and hot-spot by solar cell and interconnection circuit in PV module (PV모듈에서 태양전지와 Interconnect회로의 구성이 I-V특성과 Hot Spot에 미치는 영향)

  • Lee, Jin-Seob;Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.241-246
    • /
    • 2008
  • In this paper, we analyze the I-V curve and hot-spot phenomenon caused by solar cells' serial and parallel connected circuit. The mis-match loss of parallel interconnection with low Isc string decrease lower than serially interconnected one and temperature caused by hot-spot does. Also, mis-match loss of parallel interconnection with low Voc string increase more than serially interconnected one. The string having low Voc happened hot-spot phenomenon when open circuit. The bad solar cell in string gives revere bias to good solar cell and make hot-spot phenomenon. If we consider the mis-match loss, when designing PV module and array. the efficiency of PV system might increase.

  • PDF

A Novel Simulation model of Solar Cell using EMTDC (EMTDC를 이용한 태양전지의 새로운 시뮬레이션 모델)

  • Park, Min-Won;Kim, Bong-Tae;Lee, Jae-Deuk;Yu, In-Keun;Sung, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.113-115
    • /
    • 2000
  • So far, it was very difficult to simulate the dispersed generation system including PV generation system using EMTP or EMTDC because the source of the dispersed generation system has a particular VI characteristic equation. In this paper, a novel simulation method of PV generation system has proposed and a new solar cell component for EMTDC is also developed. The VI characteristic equation of solar cell is used in order to realize the solar generation system in EMTDC simulation. Consequently the simulation of PV power generation system using field data is realized and acceptable results, which show close match between the real data of PV panel and the simulated data, were obtained.

  • PDF

The Durability Estimation of Crystalline PV Module according to Mechanical Stress (결정질 태양전지모듈의 외부 응력에 따른 장기적 내구성 예측)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.35-36
    • /
    • 2008
  • In this paper, we studied the long term durability estimation for crystalline photovoltaic module while exposing to mechanical stress. Solar cell and PV module have many different kinds of stresses from cell to module fabrication. For this reason, some solar cell shows micro crack that decrease crystallization. In here, we expose artificial mechanical load on surface of PV module. Through this, the periodic external force on PV module might give an negative effect. The further analysis is described in the following paper.

  • PDF

A Dynamic Model of Single Crystalline Photovoltaic Cells Incorporating Thermo-Electric Characteristics

  • Ghods, Amirhossein;Kim, Katherine A.;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.373-374
    • /
    • 2015
  • This paper proposes a dynamic thermo-electric model that links electrical parameters with thermal parameters. In this model, the irradiance and ambient temperature are used to calculate the cell temperature based on a four-layer model that includes the PV cell and surround materials. The calculated cell temperature is then used in the electrical model to accurately adjust the PV electrical characteristics. Dynamic PV characteristics, parallel capacitive and series inductive components, are added to the conventional single-diode model. The results show the effectiveness of this model rather than other conventional models of a PV panel.

  • PDF

A Novel Single Converter and Single Inverter (1Con-1Inv) Topology and Control Algorithm for Photovoltaic-Fuel Cell Hybrid System (태양광-연료전지 하이브리드 발전을 위한 새로운 단일 컨버터 및 단일 인버터 (1Con-1Inv) 회로 및 제어 알고리즘)

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Won, Chung-Yuen;Lee, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2200-2208
    • /
    • 2009
  • This paper presents a novel single converter and single inverter (1Con-1Inv) topology for photovoltaic (PV)-fuel cell (FC) hybrid system and a new control scheme for the PV-FC hybrid system is then proposed. The new topology and the unique algorithm can minimize volume and production cost of the hybrid system. Moreover, system efficiency can improve due to reduction of losses of hardware components and other control factors are well regulated using just 1Con-1Inv with the help of the proposed control algorithm. The validity of proposed algorithm is verified both computer simulation using PSIM and Matlab/Simulink program and experimental with 700W of PV and 600W of FC system.

Operation Characteristics of Bypass Diode for PV Module (태양전지 모듈의 바이패스 다이오드 동작 특성 분석)

  • Kim, Seung-Tae;Park, Chi-Hong;Kang, Gi-Hwan;Lawrence, Waithiru C.K.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • In this paper, an I-V characteristics of bypass diode has been studied by counting the shading effect in photovoltaic module. The shadow induces hot spot phenomenon in PV module due to the increase of resistance in the current path. Two different types of PV module with and without bypass diode were fabricated to expect maximum output power with an increasing shading rate of 5 % on the solar cell. Temperature distribution is also detected by shading the whole solar cell for the outdoor test. From the result, the bypass diode works properly over 60 % of shading per cell with constant output power. Maximum power generation in case of solar cell being totally shaded with bypass diode decreases 41.3 % compared with the one under STC(Standard Test Condition). On the other hand, the maximum output power of the module without bypass diode gradually decreases by showing hot spot phenomenon with the increase of shading ratio on the cell and finally indicates 95.5 % of power loss compared with the output under STC. Finally the module temperature measured increases around $10^{\circ}C$ higher than that under STC due to hot-spots which come from the condition without bypass diode. It has been therefore one of the main reasons for degrading the PV module and shortening the durability of the PV system.

The PV MPPT & Charge and Discharge Algorithm for the Battery Included Solar Cell Applications (배터리 내장형 초소형 태양광 장치용 PV MPPT 및 충방전 제어 알고리즘)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lae, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.69-75
    • /
    • 2013
  • To increase the efficiency of the photovoltaic, almost photovoltaic appliances are controlled by Maximum Power Point Tracking(MPPT). Existing most of the PV MPPT techniques have used power which multiplies sensed output current and voltage of the solar cell. However, these algorithms are unnecessarily complicated and too expensive for small and compact system. The other hand, the proposed MPPT technique is only one sensing of the MPPT converter's output current, so there is no need to insert another sensors of battery side. Therefore, this algorithm is simpler compared to the traditional approach and is suitable for low power solar system. Further, the novel proper charge/discharge algorithm for the battery with PV MPPT is developed. In this algorithm, there is CC battery charge mode and load discharge mode of the PV cell & battery dual. Also we design current control to regulate allowable current during the battery charging. The proposed algorithm will be applicable to battery included solar cell applications like solar lantern and solar remote control car. Finally, the proposed method has been verified with computer simulation.

Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode (홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성)

  • Shin, Woo-Gyun;Go, Seok-Hwan;Ju, Young-Chul;Song, Hyung-Jun;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

A study on PV-AF-SPE system connected with utility (계통 연계형 PV-AF-SPE 시스템에 관한 연구)

  • Lee, Dong-Han;Lee, Suk-Ju;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.117-120
    • /
    • 2006
  • In this paper an integrated model of PV-AF (Photovoltaic-Active Filter) and PV-SPE(Photovoltaic Solid Polymer Electrolyte) system using PSCAD/EMTDC were explained in detaiil. The main concept of PV-AF system starts from the 'harmonics'. In order to deliver power to utility, PV system essentially needs a converter system. Here PV-AF system adds the function of active filter to the converter system installed in PV system, which was introduced already in several papers. PV-SPE system has been studied as a replacement of existing hydrogen production technology that emits large amount of carbon dioxide into atmosphere. Until now, these two systems, PV-AF and PV-SPE, have been considered separately However, in this paper, characteristics and advantages of combined system are discussed in detail.

  • PDF

The analysis of temperature and light intensity characteristics of PV modules with solar cell type (Cell-Type에 따른 PV모듈의 일사강도와 온도 특성 비교)

  • Bae, Jong-Guk;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1316-1317
    • /
    • 2011
  • This paper presents analysis of temperature and light intensity characteristics of PV modules with solar cell type. Taking the effect of sunlight irradiance on the cell temperature, the first experiment takes ambient temperature as reference input and uses the solar insolation as a unique varying parameter. Then taking the effect of the cell temperature on sunlight irradiance, the second experiment takes 1000W/$m^2$ as reference input and uses the cell temperature as a unique varying parameter. As a result, varying sunlight irradiance, the Cell-Type with the smallest change in output is HIT and the Cell-Type with the biggest change in output is a-Si. Varying the cell temperature, the Cell-Type with the smallest change in output is a-Si and the Cell-Type with the biggest change in output is Single-Si. And considering both temperature and light intensity characteristics, the Cell-Type with the smallest change in output is HIT.

  • PDF