• 제목/요약/키워드: PV Cell

검색결과 505건 처리시간 0.029초

A Multiagent-Based Hybrid Power Control and Management of Distributed Power Sources

  • Yoon, Gi-Gab;Hong, Won-Pyo;Lee, Ki-Hong
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.70-81
    • /
    • 2011
  • In this paper, a multi-agent control system for DC-coupled photovoltaic (PV), fuel cell (FC), ultracapacitor(UC) and battery hybrid power system is studied for commercial buildings & apartment buildings microgrid. In this proposed system, the PV system provides electric energy to the electrolyzer to produce hydrogen for future use and transfer to the load side, if possible. Whenever the PV system cannot completely meet load demands, the FC system provides power to meet the remaining load. A multi-agent system based-power management and control algorithm is proposed for the hybrid power system by taking into account the characteristics of each power source. The main works of this paper are hybridization of alternate energy sources with FC systems using long and short storage strategies to build the multi-agent control system with pragmatic design, and a dynamic model proposed for a PV/FC/UC/battery bank hybrid power generation system. A dynamic simulation model for the hybrid power system has been developed using Matlab/Simulink, SimPowerSystems and Stateflow. Simulation results are also presented to demonstrate the effectiveness of the proposed multi-agent control and management system for building microgrid.

고온고습 시험을 통한 태양전지의 장기 신뢰성에 관한 연구 (Study on the Long-term Reliability of Solar Cell by High Temperature & Humidity Test)

  • 강민수;전유재;김도석;신영의
    • 에너지공학
    • /
    • 제21권3호
    • /
    • pp.243-248
    • /
    • 2012
  • 본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험조건은 KS C IEC-61215에서 제시한 PV 모듈하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85%, 1000hr 동안 수행하였다. EL(Electroluminescence)촬영을 통하여 Cell 표면의 이상 유 무를 분석한 결과, 시간이 경과함에 따라, 부분적으로 표면이 손상되어 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell 및 다결정 Cell의 효율은 각각 17.7%, 15.5%였으며, 1000hr 수행 후 15.6%, 14.0%로 각각 11.9%와 9.3%의 감소율을 보였다. 또한, 경년 시 나타나는 전기적 특성을 분석하기 위하여 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 후 단결정 Cell은 78.7%에서 75.0%로 4.7%, 다결정 Cell은 78.1%에서 76.7%로 1.8%의 감소율을 보였다. 태양전지 실리콘의 원자배열 및 순도에 따라 효율 변화에 영향을 받아 단결정 Cell이 다결정 Cell보다 효율저하가 크게 나타났다고 판단된다. 또한, FF감소율보다 효율 감소율이 크게 저하된 것을 확인할 수 있었으며, 이는 Cell의 외부환경적 요인에 의한 표면 손상이 p-n접합층 접촉저항과 경년 시 나타나는 FF 감소율보다 크게 영향을 준 것으로 판단된다.

리본 두께에 따른 태양전지 Bowing현상 연구 (A Study on Bow of Silicon Solar Cell by Soldering Different Thickness of Ribbon)

  • 윤나리;정태희;신준오;강기환;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.68-68
    • /
    • 2010
  • To reduce PV manufacturing costs, the thickness of solar cell is getting thinner. Bow is shown after cooling down the temperature of solder cell. It happens because of different thermal expansion coefficients of different metals. Bowed cell can make micro crack while module processing and it can drop off efficiency of PV module. As thinner solar cell is produced, the thickness of ribbon should be concerned to prevent extra bow. In this paper we investigate the contrast of deflection when we solder different thickness of ribbons on same solar cell. This approach would help to find out the optical thickness of ribbon for particular thickness of solar cell later on.

  • PDF

Overall efficiency enhancement and cost optimization of semitransparent photovoltaic thermal air collector

  • Beniwal, Ruby;Tiwari, Gopal Nath;Gupta, Hari Om
    • ETRI Journal
    • /
    • 제42권1호
    • /
    • pp.118-128
    • /
    • 2020
  • A semitransparent photovoltaic-thermal (PV/T) air collector can produce electricity and heat simultaneously. To maximize the thermal and overall efficiency of the semitransparent PV/T air collector, its availability should be maximum; this can be determined through a Markov analysis. In this paper, a Markov model is developed to select an optimized number of semitransparent PV modules in service with five states and two states by considering two parameters, namely failure rate (λ) and repair rate (μ). Three artificial neural network (ANN) models are developed to obtain the minimum cost, minimum temperature, and maximum thermal efficiency of the semitransparent PV/T air collector by setting its type appropriately and optimizing the number of photovoltaic modules and cost. An attempt is also made to achieve maximum thermal and overall efficiency for the semitransparent PV/T air collector by using ANN after obtaining its minimum temperature and available solar radiation.

Photovoltaic Micro Converter Operated in Boundary Conduction Mode Interfaced with DC Distribution System

  • Seo, Gab-Su;Shin, Jong-Won;Cho, Bo-Hyung;Lee, Kyu-Chan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.44-45
    • /
    • 2011
  • Research on photovoltaic (PV) generation is taking a lot of attention due to its infinity and environment-friendliness with decrease of price per PV cell. While central inverters connect group of PV modules to utility grid in which maximum power point tracking (MPPT) for each module is difficult, micro inverter is attached on each module so that MPPT for individual modules can be easily achieved. Moreover, energy generation and consumption efficiency can be much improved by employing direct current (DC) distribution system. In this paper, a digitally controlled PV micro converter interfacing PV to DC distribution system is proposed. Boundary conduction mode (BCM) is utilized to achieve zero voltage switching (ZVS) of active switch and eliminate reverse recovery problem of passive switch. A 120W prototype boost PV micro converter is implemented to verify the feasibility and experimental results show higher than 98% efficiency at peak power and 97.29% of European efficiency.

  • PDF

PSCAD/EMTDC를 이용한 태양광발전용 태양전지 어레이의 서지특성분석 (Impedance Analysis and Suree Characteristics of PV Array with PSCAD/EMTDC)

  • 이기옥;최주엽;강기환;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.255-258
    • /
    • 2003
  • Photovoltaic(PV) array, which is generally installed outside, has the possibility to be damaged by high voltage due to lightning. Because the electrical characteristics of PV array have not been fully identified by lightning yet, there is a very important issue whether PV array should be connected with ground or not. In this paper, a basic model of PV array is provided considering the PV cell's barrier capacitance and ground capacitance for analysis of electrical characteristics by lightning using PSCAD/EMTDC.

  • PDF

PV 모듈에서 온도 영향에 의한 micro-crack 성장과 전기적 특성 분석 (The analysis of growth and electrical characteristics of micro-crack with thermal effect in PV module)

  • 송영훈;강기환;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1318-1319
    • /
    • 2011
  • In this paper, we analyzed of growth and electrical characteristics of micro-cracks with thermal effect in PV module. The micro-cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because microcracks accelerated aging by thermal cycling test. according to IEC61215. Before every test, we checked output and EL image of PV module.

  • PDF

중국 티베트 지역의 100kWp급 태양광발전시스템 성능분석 (Performance Analysis of 100kWp Photovoltaics System in Tibet)

  • 김석기;최봉하;박수억;송진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.284-287
    • /
    • 2007
  • This paper presents the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea. The economical analysis has shown that with the current prices, investment in a grid connected PV systems is generally profitable

  • PDF

PV모듈에서 후면Sheet의 광학적 특성에 따른 전기적 출력 특성 (Electrical Characteristics of PV Module According to Optical Characteristics of Back-sheet)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, we analyze the electrical characteristics of PV depending on distance among solar cells before and after lamination process. From the result, the PV module's maximum power increases about 3.37% when solar cells's distance is 10mm. And the maximum power increases up to 8.42% when solar cells's maximum distance is 50mm. It is assumed that PV module's surface temperature decreases because of increasing distance between solar cells that would give high power generation. Also, short distance between solar cell and frame result in contamination on glass. When considering reduced maximum power caused by contaminant, from that. we can fabricated PV module of lower cost with high performance.

  • PDF

PV 시스템에 대한 PSPICE 모델링과 시뮬레이션 (PSPICE Modelling and Simulation about PV System)

  • 백동현;송호빈;정형용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.163-165
    • /
    • 2009
  • Many photovoltaic (PV) systems are being developed and installed. For a PV developer, simulations are required before the experimental testing. However, most simulation tools do not offer data libraries for PV systems, so that some Institutes who try to use such software will be in difficulty. In this paper, simulations of performance and stability have been carried out using the software PSPICE. In this paper, the modelling of solar cell arrays, photovoltaic modules, PV generators, batteries and drive systems is carried out based on mathematical equivalence circuits and available data, and the models are converted into a data library for PSPICE that is user friendly. System variations can be modeled by simple parameter variation. To verify the accuracy of the simulation library, various models were run and compared to known systems.

  • PDF