• 제목/요약/키워드: PV모듈

검색결과 440건 처리시간 0.025초

Cascaded Buck-Boost 컨버터를 이용한 태양광 모듈 집적형 저전압 배터리 충전 장치 개발 (Development of PV Module Integrated Type Low Voltage Battery Charger using Cascaded Buck-Boost Converter)

  • 김동희;이희서;이영달;이은주;이태원;이병국
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.471-477
    • /
    • 2012
  • In this paper, in order to use module integrated converter using cascaded buck-boost converter for a low battery charger in stand-alone system, a charging algorithm which considers photovoltaic and battery status and PWM controllers which are changed according to charging modes are proposed. The proposed algorithm consists of constant current mode, constant voltage mode and maximum power point tracking mode which enables the battery to charge with maximum power rate. This paper also presents design of cascaded buck-boost converter that is the photovoltaic charger system. A 150W prototype system is built according to verify proposed the charger system and the algorithm.

비파괴 분석법을 적용한 결정질 태양전지 모듈의 Snail trail 현상 연구 (Non-destructive Analysis of Snail Trail on Silver Grid Line in PV Module)

  • 김다정;김남수;황경준;이주호;정신영;정대홍
    • Current Photovoltaic Research
    • /
    • 제2권2호
    • /
    • pp.63-68
    • /
    • 2014
  • In recent years, discoloration defects, called as snail trail, have been observed at many crystalline photovoltaic modules after a period of time ranging from several months to several years after initial installation. It has been reported that this phenomenon doesn't impact on the performance of photovoltaic modules, but it can be detected through simple visual inspection. The origin and detailed mechanism for the formation have not been identified. In this study, non-destructive analysis by Raman spectroscopy has been carried out to investigate the origin of this phenomenon. In parallel, destructive analysis by scanning electron microscopt and transmission electron microscopy was also performed in order to confirm the results from non-destructive method. Through the extensive analysis, it was found that the main cause for discoloration is the formations of $Ag_2CO_3$ and $AgC_2H_3O_2$. Detailed mechanism for the formation of these particles was indentified through systematic studies.

고온고습 시험을 이용한 실리콘 태양전지 모듈의 수명 예측 연구 (A study of lifetime prediction of PV module using damp heat test)

  • 오원욱;강병준;박노창;탁성주;김영도;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.63.1-63.1
    • /
    • 2011
  • To analyze the phenomenon of corrosion in the PV module, we experimented damp heat test at $85^{\circ}C$/85% relative humidity(RH) and $65^{\circ}C$/85% RH for 2,000 hours, respectively. We used 30 mini-modules designed of 6inch one cell. Despite of 2,000 hours test, measured $P_{max}$ is not reached failure which is defined less than 80% compared to initial $P_{max}$. Therefore, we calculate proper curve fitting over 2,000 hours. Data less than 80% $P_{max}$ is found and B10 lifetime is calculated by the number of failure specimens and weibull distribution. Using B10 lifetime that the point of failure rate 10% and Peck's model, the predictable equation of lifetime was derived under temperature and humidity condition.

  • PDF

Photovoltaic module의 발전 온도에 따른 EVA 광 특성 연구 (A Study on EVA Optical Characteristics By Generation Temperature of PV module)

  • 우성철;정태희;민용기;강기환;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.31-35
    • /
    • 2011
  • Photovoltaic modules are well known to be one of the most eco generation of electricity. But usually study solar cell. Otherwise, PV modules are also important in power generation. We have to check other subsidiary materials. In this work benefit of using optically superior encapsulation materials(EVA) in generation temperature is demonstrated. Optical characterization of three EVA products demonstrates reduced transmission in the visible ray region of the solar spectrum. It will have a decisive effect to the module efficiency. Test is shown reduction of reflectance and transmittance. Reflections is dependent on the low iron glass. It can be seen between a specific wave length(240~350mm) about 1%. Transmittance in the entire ray region of light is markedly reduced to depending on the temperature rise. The graph is shown optical properties on EVA. Transmission was reduced. about 1%.

  • PDF

방위각 및 경사각을 고려한 지역별 태양광 모듈 배치안 검토 (A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region)

  • 박성현;서장후
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.461-466
    • /
    • 2012
  • Recently, building energy systems with solar collector and solar module have increased to improve energy problem, a heat island, a global warming and carbon dioxide emissions. In this study, value of solar radiation in areas was analyzed using TRNSYS simulation, and the optimum tilt and orientation angle for installing a photovoltaic module was examined. Average values of the weather data in the past twenty years in areas were used as input data. The results show that the tilt angle of a photovoltaic module for gaining the annual maximum solar radiation varies in different localities, and values of the annual solar radiation gained by using the variable photovoltaic module increased by 2.5 percent as compared with that gained by using the fixed photovoltaic module. When fixed photovoltaic module is installed, it should be examined the tilt and orientation angle for installing a photovoltaic module was examined.

분산모듈형 태양광 전력조절기의 독립운전 제어 (Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation)

  • 서정원;박종후;김혜림
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

하중 분산형 새로운 태양광 추적 장치에 관한 연구 (The Study on A New PV Tracking System Including the Load Dispersion)

  • 이상훈;정태욱
    • 전력전자학회논문지
    • /
    • 제11권6호
    • /
    • pp.508-519
    • /
    • 2006
  • 본 논문에서는 태양광 발전 시스템 중 태양전지의 효과적인 사용을 위해 태양이 항상 법선을 이루면서 태양전지 모듈에 입사되게 하는 위치추적 시스템에 대한 새로운 방법을 제시하였다. 점 하중 방식인 해바라기 타입의 태양광 추적 장치의 단점을 극복하기 위해 선 하중 방식 태양광 발전 시스템으로 경제적인 태양광 추적 장치를 제안하였다. 제안된 방식에 대하여 여러 가지 검증된 태양 기하학 이론을 바탕으로 현재 사용 중인 프로그램 방식의 위치추적 시스템을 개선할 수 있는 제어방법 및 구조를 도출하고자 한다.

태양전지모듈의 EVA sheet 열화와 전극부식이 전기적 특성에 미치는 영향 (The Effect of Electrical Properties with Degradation of EVA sheet and Electrode in Photovoltaic Module)

  • 강기환;박지홍;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.26-28
    • /
    • 2005
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 15 years shows around 13~20% drop of electrical properties due to the interconnect degradation and PV module passed 19 years has been found to drop of around 20% mainly by the encapsulant discoloration. Fill factor of the electrode oxidized photovoltaic module has been dropped by the amount of 6~10% due to the change of irradiance. It is because maximum voltage(Vmp) decreases according to the increase of irradiance.

  • PDF

EVA Sheet의 Gel Content가 태양전지모듈의 내구성에 미치는 영향 (The Effect of EVA Sheet Gel Content on Photovoltaic Modules Durability)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.20-21
    • /
    • 2006
  • In this paper, we studied the influence of EVA sheet gel content on photovoltaic module durability. Depending on thermal curing temperature and time during lamination, there are dramatic changes on chemical and physical characteristics. To find the optimum PV module process condition, Glass/EVA/Back Sheet scheme was made. Gel Content, FT-IR spectrum and SEM were used for the detail analysis. From these results, $110^{\circ}C/6min$ and $130^{\circ}C/4min$ lamination condition could be suggested for the best one for durable PV module processing. The further analysis is described in the following paper.

  • PDF

태양광 발전시스템의 MPPT 알고리즘 분석 (Analysis of various MPPT algorithms for PCS)

  • 심재휘;양승대;정승환;최주엽;최익;안진웅;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.16-21
    • /
    • 2011
  • Since the maximum power operating point(MPOP) of PCS alters with changing atmospheric conditions temperature conditions shadow conditions it is important to operate for PCS to keep maximum power point tracking(MPPT) continuously. This paper presents the results of modeling PV system by PSIM simulator and investigates the influence on the PV system from aspect of power quality i.e. voltage drop. This paper investigates four MPPT algorithms; Perturbation & Observation(P&O) Improved P&O Incremental Conductance(Incond) Differential coefficient method simulated with irradiation temperature change and shadow conditions.